Pronk Technologies Flow Trax FT-2 Operator's Manual

Pronk Technologies Flow Trax FT-2 Operator's Manual

Infusion device analyzer

Advertisement

®
Flow Tr ax
Infusion Device Analyzer
Operator's Manual
Pronk Technologies
2017 07-18
www.pronktech.com
800-541-9802
Page 1
©2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flow Trax FT-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pronk Technologies Flow Trax FT-2

  • Page 1 ® Flow Tr ax Infusion Device Analyzer Operator’s Manual Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 1 ©2015...
  • Page 2 CE Mark label, as shown below, affixed to the unit. CE Marked products also comply with the WEEE directive for category 9 Monitoring and Control Instrumentation products. Do not dispose of this product as unsorted waste. To dispose, contact Pronk Technologies at support@pronktech.com. A Return Material Authorization will be issued to return the unit for disposal.
  • Page 3 The device shall only be used with the AC-DC adaptor provided or with AA Alkaline or Lithium batteries. Operate this product using only accessories provided by Pronk Technologies. If this equipment is used in a manner not specified by the Pronk Technologies, the protection provided by the equipment may be impaired.
  • Page 4: Table Of Contents

    HydroBalance Setup and Use………………………………………….. 16 DataSnap Electronic Data Transfer and Control……………………. Serial Communications Protocol……………………………………… 19 Updating Software……………………………………………………… 21 Technical Specifications………………………………………………… 22 Flow Rate vs. Time Required Chart…………………………………..23 Warranty and Service Information…………………………………..24 Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 4 ©2015...
  • Page 5: Accessories And Symbols

    USB adapter cable for connecting FlowTrax to PC for software updates. Temperature Probe Adapter connects to FlowTrax and YSI temperature probe. Note: Temp. 501-0404 Extension Cable probe not sold by Pronk Technologies Bottle Brush 501-9913 Utilized to clean FlowTrax sample tube. Cleaning Solution ®.
  • Page 6: Introduction

    Flow Trax FT-2 Operation Instructions Introduction The FlowTrax is quick to set up, easy to use and ready to go where you need to be. Your FlowTrax comes with a small 6VDC/1.8 amp power supply, a carrying case, two spare filter screen assemblies, a high pressure fitting, syringe, 3 way stopcock, output hose, USB cable, Temperature Probe extension cable, bottle brush, flush bottle, bottle of glass tube cleaner, Operators’...
  • Page 7: Detailed Operating Instructions

    Flush FlowTrax by selecting FUNCTION then FLUSH and running pump at 900+ml/hr for approximately 20ml Volume. • Leave FlowTrax on the FLUSH screen, reprogram IV Pump for 600ml/hr and 20ml Volume. • Restart IV pump. Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 7 ©2015...
  • Page 8: Flow & Volume Measurements

    NOTE: You do not need to remove the IV bracket from the back cover. It is acceptable for FlowTrax to lean on one side when horizontal. Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 9: Trending Flow And Volume

    Occlusion. The pressure value below MAX AT is the real time pressure. g) Document “MAX” pressure indicated on FlowTrax. h) The last “MAX” pressure will remain on the display for 2 hours, or until “RESET FLOW” is pressed. Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 10: Air-In-Line Testing

    Very Low Flow Rates: For flow rates of 20ml/hr or less, lay FlowTrax on its back so that the buttons are facing the ceiling. If FlowTrax is mounted to an IV pole, turn it 90 degrees or remove from pole clamp and lay it on its Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 11: Contamination Of Flowtrax Fluid Path

    A repair of damage during the warranty period appearing to be the result of non-recommended test fluids being used will be performed at a nominal flat rate. See Services chart or contact Pronk Technologies for details.
  • Page 12: Supply

    NOT face toward FlowTrax rear cover Clean the Product (Outside) To clean the outside of the FlowTrax, disconnect from the power supply and use only a damp cloth with mild detergent. Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 12 ©2015...
  • Page 13: Preventative And Routine Maintenance Chart

    The Pronk FlowTrax calibration System Annual procedure must be followed by an authorized calibration company using NIST traceable fixtures defined in the procedure to guarantee the device meets all specifications. Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 13 ©2015...
  • Page 14: Troubleshooting Tips

    / record with your cursor. Make sure you select F8 (Stream Data OFF) before using with DataSnap leaving a file / form / record that you were using to collect streaming data. Contact Pronk Technologies Technical Support at: (800-541-9802) Unable to resolve Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 15: Troubleshooting Flow Chart- Priming

    Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 15 ©2015...
  • Page 16: Pump Manufacturer Height Requirements Chart

    Infusion pump performance over extended periods of time. In either case, the data will go directly into a file, form or record you have open on your pc where you have selected a cell or box that results are normally typed into (including notes fields in forms). Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 17 DataSnap Script: The Script file defines the action of the Function keys and is also located on the FlowTrax User Guide DVD provided. It was developed by Pronk Technologies as “shareware” and there is no implied or specific warranty or support. It can be modified by users where more customization is needed.
  • Page 18 Now that TWedge is running and configured for that USB port, you can open any file, form or record, click on a text box /cell and use the Function keys to capture results from FlowTrax into that text box or cell. Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 19: Serial Communications Protocol

    Zeros pressure transducer offset and Max Press ‘Z’ Command Zero Max Pressure ‘z’ Zeros Maximum Pressure Poll Tube Calibration Returns tube cal, and settings: bubble size, front optical, rear ‘C’ and settings optical, e.g.: “C,1290,84,50,49” Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 19 ©2015...
  • Page 20 0.01PSI. Pressure curves begin immediately, regardless of 200ms prime status and continues to run until “q” is sent or a different trumpet selection is made. All curves off ‘q’ Turns pressure and trumpet curves off Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 20 ©2015...
  • Page 21: Updating Software

    Wait for full boot up to complete. Verify successful software upload by pressing SETUP button and confirming the correct version number at the top of the Setup page. Your new software has been completely uploaded. Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 21 ©2015...
  • Page 22: Technical Specifications

    *Requirements for Flow Rate and Volume accuracy specification: Distilled water as test solution, output bottle height of 0 to 18” (45.7 cm) above FT output, FT horizontal for rates below 21ml/hr, vertical for rates at or above 21ml/hr. Pronk Technologies 2017 07-18 www.pronktech.com...
  • Page 23: Flow Rate Vs. Time Required Chart

    Required Required VOLUME (ml/hr) (ml/hr) VOLUME 0.5 – 10 0.75 5.75 1.25 6.25 1.75 6.75 2.25 7.25 2.75 7.75 3.25 8.25 3.75 8.75 4.25 9.25 4.75 9.75 200 - 999 5.25 Pronk Technologies 2017 07-18 www.pronktech.com 800-541-9802 Page 23 ©2015...
  • Page 24: Warranty And Service Information

    If Pronk Technologies determines a fault has occurred as a result of test fluid being used that is not recommended, that repair will be billable. A repair during the warranty period resulting from non-recommended test fluids being used will be performed at a nominal flat rate.
  • Page 25 Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Script File: It was developed by Pronk Technologies as “shareware” and there is no implied or specific warranty or support. It can be modified by users where more customization is needed.

Table of Contents

Save PDF