Installation instructions
Door control
TS 959
51171559_a_11_2012
Pos: 1.3 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1
Status: 07.11.2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS 959 and is the answer not in the manual?

Questions and answers

Summary of Contents for Elektromaten TS 959

  • Page 1 Pos: 1.2 /BA_Module_Manuell/Torsteuerung TS 959/01_Deckblatt_68073 @ 7\mod_1347867455430_28.docx @ 762690 @ @ 1 Installation instructions Door control TS 959 51171559_a_11_2012 Status: 07.11.2012 Pos: 1.3 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1...
  • Page 2 Pos: 2.2 /BA_Module_Manuell/Torsteuerung TS 959/02_Leerseite_68073 @ 7\mod_1347867522263_28.docx @ 762705 @ @ 1 GfA-ELEKTROMATEN Australia Pty Ltd P.O. Box 267 Roseville 2069 NSW Telephone: 02 9882 2782 Facsimile: 02 9882 2783 Email: info@gfa-elektromaten.net Web: www.gfa-elektromaten.net === Ende der Liste für Textmarke inhalt3 ===...
  • Page 3: Table Of Contents

    Pos: 3.2 /BA_Module_Manuell/Torsteuerung TS 959/03_Inhaltsverzeichnis @ 6\mod_1344867191501_28.docx @ 757614 @ @ 1 Table of contents General safety information ....................5     Technical data ........................ 6     Mechanical installation ....................7     Electrical installation ....................... 8    ...
  • Page 4 X5: Input, control device ....................23   Extended hold-to-run function ..................23   X20 potential-free relay contact ..................24   Force monitoring (DES only) ................... 24   Travel time monitoring (NES only) ................... 25   Maintenance cycle counter ....................26  ...
  • Page 5: General Safety Information

    Pos: 4.2 /BA_Module_Manuell/Torsteuerung TS 959/04_Sicherheitshinweise @ 6\mod_1344867202506_28.docx @ 757629 @ 1 @ 1 1 General safety information Specified normal use The door control is intended for a power-operated door with a drive unit. The safe operation is only guaranteed with normal specified use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions.
  • Page 6: Technical Data

    Pos: 5.1 /BA_Module_Manuell/Torsteuerung TS 959/05_Technische Daten @ 6\mod_1344924152708_28.docx @ 757670 @ 1 @ 1 2 Technical data Series TS 959 Dimensions W x H x D 155 x 380 x 80 Assembly vertical Assembly Vibration free of vibration Operating frequency...
  • Page 7: Mechanical Installation

    Pos: 6.1 /BA_Module_Manuell/Torsteuerung TS 959/06_Mechanische_Montage @ 6\mod_1344924433864_28.docx @ 757688 @ 1 @ 1 3 Mechanical installation Control installation!  Only use indoors  Mounting only on a level ground free of vibration  Only vertical mounting position permissible  Door must be visible from the assembly site...
  • Page 8: Electrical Installation

    Pos: 7.1 /BA_Module_Manuell/Torsteuerung TS 959/07_Elektrische Montage @ 6\mod_1344924449762_28.docx @ 757703 @ 1222222 @ 1 4 Electrical installation Warning - Risk of electrocution!  Disconnect the cables (mains OFF) and check that they are voltage-free  Observe the applicable regulations and standards ...
  • Page 9: Connection Overview For Connection Cables

    Connection overview for connection cables DES and NES DES connection cable for limit switch connection cables for motor X13 Motor plug X12 Limit switch plug Pin Core Term. Pin Core Term. Phase W 5/wh +24 V safety circuit Phase V 6/bn Channel B (RS485) Phase U...
  • Page 10: Carrying Out The Electrical Installation

    Carrying out the electrical installation ▶ Remove the covers. ▶ Open cable conduit ① or ②. ▶ Insert and connect control/drive connection cable in the open cable conduit ① (from below) or ② (from above). ▶ Tighten cable gland. Caution - Avoid damage to components! ...
  • Page 11: Mains Supply

    Mains supply 3-phase current, 3-phase current, 1-phase 1-phase with neutral without neutral symmetrical asymmetrical conductor conductor Mains connection to control Completion of electrical installation Connect any other control devices and/or safety devices. Install and tighten cable entries and/or cable glands. For initial operation of the control, leave the covers open.
  • Page 12: Overview Of Control

    1.5-A micro-fuse with time delay Emergency stop button Motor socket Control device, external three push button Selector switch Potential-free relay contact “Open” button “Stop” button “Close” button Display Pos: 7.2 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1...
  • Page 13: Initial Operation Of The Control

    Pos: 8.1 /BA_Module_Manuell/Torsteuerung TS 959/08_Inbetriebnahme (Schnelleinstellung) @ 6\mod_1344924464383_28.docx @ 757718 @ 122 @ 1 5 Initial operation of the control ▶ Plug in or switch on mains supply line DES: Rapid adjustment of final limit positions 1. Check rotating direction 2.
  • Page 14: Nes: Rapid Adjustment Final Limit Positions

    3. Move to 5 cm in front of the CLOSED final limit position and set S5 pre-limit 4. Move to CLOSED final limit position and set S4 CLOSED limit switch Pos: 8.2 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1...
  • Page 15: Advanced Electrical Installation

    Pos: 9.1 /BA_Module_Manuell/Torsteuerung TS 959/09_Erweiterte elektrische Installation @ 6\mod_1344924477714_28.docx @ 757733 @ 1 @ 1 6 Advanced electrical installation External supply X1 Emergency stop X3 Relay contact X20 Relay contact X20 External supply X1 Emergency stop X3 A16 Relay A1 External device...
  • Page 16: Programming The Control

    Pos: 10.1 /BA_Module_Manuell/Torsteuerung TS 959/10_Programmierung der Steuerung @ 6\mod_1344924529099_28.docx @ 757748 @ 1 @ 1 7 Programming the control 1. Only program after rapid adjustment of final limit positions! 2. Select and confirm the menu 3.a) Set and store functions 3.b) Set and save (DES) positions...
  • Page 17: Table Of Menus

    Pos: 11.1 /BA_Module_Manuell/Torsteuerung TS 959/11_Parametereinstellungen @ 6\mod_1344924544071_28.docx @ 757763 @ 1 @ 1 8 Table of menus Operating mode Operating mode Door operating mode OPEN Hold-to-run CLOSE Hold-to-run OPEN Self hold CLOSE Hold-to-run Extended hold-to-run control Turning direction Maintain turning direction...
  • Page 18: Door Function

    Door function Door function Relay function on X20 Teach-in door positions via menu 1.7 (DES only) Impulse signal for 1 second Permanent signal Red lamp, permanent light during door movements OPEN final limit position 3 seconds permanent light CLOSE final limit position 3 seconds permanent light Red lamp, permanent light during door movements OPEN final limit position...
  • Page 19: Maintenance Cycle Counter

    Maintenance cycle counter Maintenance cycle counter Maintenance cycle preselection 01-99 corresponds to 1,000 to 99,000 cycles Cycles are counted down Reaction on reaching zero "CS" display with set value of maintenance cycle Changeover to hold-to-run and "CS" display with set value of maintenance cycle Changeover to hold-to-run and "CS"...
  • Page 20: Readout Of Information Store

    1,000 Firmware version The firmware version of the control is displayed. Deleting all adjustments Deleting all adjustments Deleting all adjustments All (factory setting)! Except for cyclus counter reading Pos: 11.2 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1...
  • Page 21: Safety Devices

    Pos: 12.1 /BA_Module_Manuell/Torsteuerung TS 959/12_Funktionsdetailbeschreibung @ 6\mod_1344924555665_28.docx @ 757788 @ 1221222222222 @ 1 9 Safety devices X2: Input, door safety switch The door safety switch is fitted to the door and connected to the door control via the spiral cable.
  • Page 22: Description Of Functions

    10 Description of functions X1: Mains supply line for control and external supply Mains supply line for control Connection via terminals X1/1.1 to X1/1.4 and PE Various mains connections: 3 N~, 3~, 1 N~ for symmetric and asymmetric motors Note! ▶...
  • Page 23: X5: Input, Control Device

    X5: Input, control device Warning!  “Hold-to-run” door operating mode: The door must be fully visible from the operating point. Note! ▶ Wire links X5.1 to X5.2 for using the control device without stop button ▶ Note “X5 control device” description Extended hold-to-run function Menu “0.1”, function type “.5”.
  • Page 24: X20 Potential-Free Relay Contact

    X20 potential-free relay contact The relay functions can be found in the “Table of menus” section under menu 2.7. Caution - Avoid damage to components!  Maximum current of 1 A at 230 VAC and 0.4 A at 24 VDC ...
  • Page 25: Travel Time Monitoring (Nes Only)

    After exiting the program, the door must carry out a full opening and closing operation in self- hold mode. The force monitoring is a self-learning system which is effective for an opening width range of 5 cm - 2 m (approx.). Slow progressive changes, e.g. gradual reduction of the spring tension, are compensated for automatically.
  • Page 26: Maintenance Cycle Counter

    Only the middle point is displayed, unless “WSD” is active, in which case both points are displayed. Execution of the “Standby” function is stopped by issuing a command or by operating the “S” selector switch. Pos: 12.2 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1...
  • Page 27: Status Display

    Pos: 13.1 /BA_Module_Manuell/Torsteuerung TS 959/13_Statusanzeige @ 6\mod_1344924569171_28.docx @ 757803 @ 1 @ 1 11 Status display Faults “F” plus a code are displayed in each case Status Fault description Measures for fault correction code Terminals X3.1 – X3.2 are open.
  • Page 28 Faults “F” plus a code are displayed in each case Status Fault description Measures for fault correction code Triggering of the force monitoring. Check the door mechanism for stiffness. Switch control off and on. ROM fault. Replace control if necessary. Switch control off and on.
  • Page 29 Commands “E” plus a code are displayed in each case Code Command description An “Open” command is active. Control inputs X5.3 A “Stop” command is active. Control inputs X5.2 A “Close” command is active. Control inputs X5.4...
  • Page 30 Upwards travel active. Flashing Closing operation active. Flashing Stoppage between the set final limit positions. Stoppage at the “Open” final limit position. Stoppage at the “Close” final limit position. Pos: 13.2 /BA_Module_Manuell/Torsteuerung TS 959/MAL_Seitenumbruch @ 6\mod_1344937085969_0.docx @ 758205 @ @ 1...
  • Page 31: Explanation Of Symbols

    Pos: 14.1 /BA_Module_Manuell/Torsteuerung TS 959/14_Zeichen_Erklärung @ 6\mod_1344924585411_28.docx @ 757818 @ 1 @ 1 12 Explanation of symbols Symbol Explanation Request: Read mounting manual Request: Check Request: Note Request: Note the setting of the menu below Default adjustment of the menu...
  • Page 32 Symbol Explanation Request: Adjustment via built in push button OPEN/CLOSE, OPEN push button upwards; CLOSE push button downwards Request: Press STOP button once via built in push-button Request: Save, press stop-button once via built in push-button Request: Save, press STOP-button for three seconds via built in push-button Request: Reset the control, press stop-button for three seconds via built in push-button Request: Start door positions...
  • Page 33: Declaration Of Incorporation/Declaration Of Conformity

    Pos: 15.2 /BA_Module_Manuell/Torsteuerung TS 959/15_Herstellererklärung @ 6\mod_1344924612586_28.docx @ 757833 @ @ 1 Declaration of Incorporation/Declaration of Conformity Declaration of Incorporation pursuant to Machinery Directive 2006/42/EC for a partly completed machine Appendix II Part B GfA - Gesellschaft für Antriebstechnik Dr.-Ing Hammann GmbH & Co KG Declaration of Conformity Wiesenstraße 81...