Configure hardware and setup management tool associated with Upgrading the System hardware Chapter 3: Convenient Useful features and the detail of system BIOS settings, SAS Features Configuration Utility, and EXPRESSBUILDER Other documents Provides the detail of NEC ESMPRO, BMC Configuration, and the other features. Express5800/E120d-M User's Guide...
4.6.1 POWER LED ( )........................37 4.6.2 STATUS LED ( ) ........................37 4.6.3 UID LED ..........................38 4.6.4 LED on a hard disk drive ......................39 4.6.5 LEDs for LAN connectors......................40 4.6.6 AC POWER LED on Power Unit ..................... 41 Express5800/E120d-M User's Guide...
Page 4
2. Installation and Connection..........................75 2.1 Installation............................75 2.1.1 Installing Rack......................... 75 2.1.2 Installing the server to the rack or removing it from the rack........... 77 2.2 Connection............................81 2.2.1 Connecting to a uninterruptible power supply (UPS)............... 83 Express5800/E120d-M User's Guide...
Page 5
4. EXPRESSBUILDER ............................95 4.1 Features of EXPRESSBUILDER ......................95 4.2 Starting EXPRESSBUILDER ....................... 95 5. Installing Software Components ........................96 6. Turning Off the Server ............................ 97 Chapter 4 Appendix ............................. 98 1. Specifications..............................99 2. Interrupt Lines............................... 100 Express5800/E120d-M User's Guide...
Unless otherwise stated, hard disk drives (HDD) described in this document refer to both of the following. Hard disk drives (HDD) Solid state drive (SSD) Removable media Unless otherwise stated, removable media described in this document refer to both of the following. USB memory Flash FDD Express5800/E120d-M User's Guide...
Windows Server 2003. *3: Used as an installation platform only. POST POST described in this document refer to the following. Power On Self-Test BMC described in this document refer to the following. Baseboard Management Controller Express5800/E120d-M User's Guide...
Trademarks Trademarks EXPRESSSCOPE is a registered trademark of NEC Corporation. Microsoft, Windows, Windows Server, Windows Vista, and MS-DOS are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Intel, Pentium, and Xeon are registered trademarks of Intel Corporation of the United States.
CE / Australia and New Zealand Statement This is a Class A product. In domestic environment this product may cause radio interference in which case the user may be required to take adequate measures (EN55022). BSMI Statement 台湾電池規制(廃棄物清理法) Turkey RoHS Express5800/E120d-M User's Guide...
Page 10
Regulatory Notices WEEE Directive Chinese RoHS Vietnam RoHS Vietnam RoHS information relevant for Vietnam market Complying with "CIRCULAR, No.30/2011/TT-BCT (Hanoi, August 10 2011), Temporary regulations on content limit for certain hazardous substances in electrical products" Express5800/E120d-M User's Guide...
2. The contents of this document may change without prior notice. 3. Do not make copies or alter the document content without permission from NEC Corporation. 4. Every effort has been made to ensure the completeness of this document. However, if you have any concerns, or discover errors or omissions, please contact your retailer.
Chapter 1 (5. Names and Functions of Parts) in this document. Safety precautions Follow the instructions in this document for the safe use of NEC Express server. This User’s Guide describes hazardous parts of the server, possible hazards, and how to avoid them. Server components with possible danger are indicated with a warning label placed on or around them (or, in some cases, by printing the warnings on the server).
Unplug the power cord of the server. Otherwise, specifically identified. Make sure to follow the an electric shock or fire may be caused. instruction. Make sure equipment is properly grounded. Otherwise, an electric shock or fire may be caused. Express5800/E120d-M User's Guide...
Do not disassemble the server, and contact the store where you purchased the product or your maintenance service company. Express5800/E120d-M User's Guide...
For inquiries regarding the installation or wiring of the power supply system, consult with the company that performed the installation or wiring, or the power company that services your area. Express5800/E120d-M User's Guide...
Do not secure the power cord with staples or damaged power cord with a power cord of the equivalents same standard. For information on replacing the power cord, contact the store where you purchased the product or a maintenance service company) Express5800/E120d-M User's Guide...
Do not get your fingers caught in the rails When mounting/removing the server onto/from the rack, be careful to avoid getting your fingers caught in the rails or cutting your fingers on the rails. Express5800/E120d-M User's Guide...
Use only the specified interface cable. Use only interface cables provided by NEC and locate a proper device and connector before connecting a cable. Using an authorized cable or connecting a cable to an improper destination may cause a short circuit, resulting in a fire.
Keep your hands and hair away from the cooling fan at the rear of the server during operation. Failure to observe this warning may cause your hands or hair to catch in the fan, resulting in personal injury. Express5800/E120d-M User's Guide...
(Do not remove or black out this label and keep it clean). If no label is attached or printed on the server, or if there is a label coming off or stained, contact your sales representative. External view Express5800/E120d-M User's Guide...
Tape media: Approximately 1 day For optional devices, we recommend you use our NEC products. Even if they are successfully installed or connected, installation of unsupported devices can cause the server to malfunction or even failure. You will be charged to repair failure or damage caused by use of such products even within warranty period.
Page 23
Keeping your equipment clean is important not only for the appearance but also for functional and safety reasons. A dusty monitor makes it difficult to see the display contents, so clean it regularly. Take rest breaks When you feel tired, take a break. Light exercise is also recommended. Express5800/E120d-M User's Guide...
Verify the condition of your server's accessories. 3. Standard Features This section describes the server’s features and the server management. 4. Names and Functions of Parts This section describes the name of each part contained in this server. Express5800/E120d-M User's Guide...
This high performance server is powered by the latest microprocessor "Intel Xeon processor". NEC’s latest technology and architectures realize high-power and high-speed operation that cannot be matched by existing servers. The server is designed with consideration of not only reliability but also expandability, which enables you to use it as a network server.
Getting Started Make sure you have all accessories and inspect them. If an accessory is missing or damaged, contact your sales representative. Important The chassis serial number plate and maintenance label is located on the server. Express5800/E120d-M User's Guide...
Memory degrade feature (logical isolation of a failed device) Memory x4 SDDC feature (available depending on DIMM type) Memory throttle-ring feature Bus parity error detection Temperature detection Error detection Internal fan monitoring feature Redundant fan system Express5800/E120d-M User's Guide...
Page 28
Three LAN ports (one for management LAN) With optional LAN riser card, two ports can be added. Ready to use No cable connection is required to install a hard disk drive (hot swap supported). Express5800/E120d-M User's Guide...
Page 29
Feature to back up and restore BIOS/BMC configuration information using EXPRESSSCOPE Profile Key ® *1:Unsupported on Xeon processor E5-2407 embedded models. *2:Processor core speed depends on processor type, number and type of DIMMs installed, and operating voltage (1.35/1.5 V). *3:In 2-CPU configuration. Up to 192 GB in 1-CPU configuration Express5800/E120d-M User's Guide...
NEC ESMPRO Agent stored in EXPRESSBUILDER. You can also monitor the server states from a management PC on network where NEC ESMPRO Manager is installed. The features available on this server are as shown in the table below.
The switch to reset BMC of this server. Use the Connect a display unit. switch only when there problem with EXPRESSSCOPE Engine 3 (BMC). To use this switch, press it at least five seconds. Note Hard disk drive number depends on your OS. Express5800/E120d-M User's Guide...
This LED indicates power supply status. recommended from the point of performance and ( 4.6.1 ) security, because LAN port 1 may receive both data. (12) Blank cover (for LAN riser card) Remove this cover to install an optional LAN riser card. Express5800/E120d-M User's Guide...
Fan connector For the supported card specifications, refer to Chapter 2 (1.9 PCI card). LAN riser card connector (14) SATA connector Lithium battery Clear CMOS Jumper switch Clear Password Jumper switch (10) Connector for USB memory module Express5800/E120d-M User's Guide...
While hardware is operating normally, STATUS LED lights green. STATUS LED is off or lights/flashes amber if there is a hardware failure. The following table lists STATUS LED patterns, their explanation and solution. If you have installed NEC ESMPRO, you can view error logs to check the causes of Tips failures.
The following table lists UID LED patterns and their explanation. UID LED pattern Explanation On (blue) The UID switch is pressed. The UID switch is not pressed. You can turn on an LED using remote management software. Tips Express5800/E120d-M User's Guide...
Do not turn off or reboot the server while a HDD is being rebuilt. Wait at least 90 seconds before installing a HDD after removing one. Do not replace a HDD while another HDD is being rebuilt. Express5800/E120d-M User's Guide...
The following table lists LINK/ACT LED patterns and their explanation. SPEED LED pattern Explanation On (amber) The port is operating with 1000BASE-T interface. On (green) The port is operating with 100BASE-TX interface. The port is operating with 10BASE-T interface. Express5800/E120d-M User's Guide...
Cold Redundant feature is enabled. – On (amber) The power cord is not connected in redundant Connect the power cable. power configuration. Power unit is failing. Contact your sales representative. Flashing (amber) Power unit is failing. Contact your sales representative. Express5800/E120d-M User's Guide...
1. Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices. 2. Installation and Connection You must place the server in a suitable location and connect some cables following this section. Express5800/E120d-M User's Guide...
If you did not purchase any optional device requiring installation, you may skip this section. Important Use only the devices and cables specified by NEC. You will be charged to repair damages, malfunctions, and failures caused by the use of any devices or cables not specified for use with this server even within the warranty period.
– Keep any component in an anti-static bag until you actually install it to the server. – Hold any component by its edge to avoid touching any terminals or parts. – To store or carry any component, place it in an anti-static bag. Express5800/E120d-M User's Guide...
7. Install power supply units Refer to Chapter 2 (1.13 Power Supply Unit). This is the end of the installation or removal procedures for internal optional devices. Continue the setup with reference to Chapter 2 (2.2 Connection). Express5800/E120d-M User's Guide...
When the server is working or before you turn the server off or disconnect a cable from the server, be sure to identify the target server by using UID Switch first. To turn UID LED on, press UID Switch. When it is pressed again, the LED will be off. switch Express5800/E120d-M User's Guide...
2. Lift the lever while pushing the locking mechanism toward right. Hold the handle, and pull out the server module horizontally,. Important If you remove the server module from module enclosure, wait at least 30 seconds before insert it again into enclosure. Express5800/E120d-M User's Guide...
Chapter 2 (1.2 Anti-static Measures). Make sure to use the processor authorized by NEC. Installing a third-party processor may cause a failure of the processor as well as the motherboard. Repair of the server due to failures or damage resulted from installing such a processor will be charged.
Page 49
Bring down the processor straight without tilting or sliding it in the socket. 7. Lightly push the processor to the CPU socket, and close the plate. 8. Close the socket lever to fix the processor. Express5800/E120d-M User's Guide...
Page 50
If the heat sink is not level, remove it, and then install it again. The following probably causes the heat sink not to be level: – The CPU is not positioned correctly. – All screws are not completely tightened. Do not move the secured heat sink. Express5800/E120d-M User's Guide...
To remove the heat sink from the processor, first turn the heat sink to the left and right lightly to make sure that the heat sink can be apart from the processor. Removing the heat sink with it adhering to the processor may cause the processor and/or CPU socket to be defected. Express5800/E120d-M User's Guide...
Red Hat Enterprise Linux 6 (x86_64) 384GB (ISV-certified) VMware ESX 4.1 *1 256GB or 1TB 256GB or 384GB VMware ESXi 5.0 *2 384GB *1 Up to 255 GB on virtual machine. *2 Up to 1TB on virtual machine. Express5800/E120d-M User's Guide...
To remove DIMM, reverse the installation procedure. Note When removing a defective DIMM, check error messages displayed on POST or NEC ESMPRO and check the DIMM socket where the defective DIMM is installed. Take the steps below after replacing or removing DIMMs.
1. Refer to steps 1 to 3 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. 2. Remove the three screws from bracket, and remove bracket. 3. Remove the three screws from the blank cover. Blank cover 4. Remove the blank cover. Note Keep the removed cover for future use. Express5800/E120d-M User's Guide...
7. Install the port cover provided with LAN Riser Card, and secure it with four screws you have removed in steps 2 and 3. 1.8.2 Removal Remove LAN Riser Card in reverse order of installation steps. Important To maintain the cooling effect in the server, install the blank cover in the vacant LAN Riser Card slot. Express5800/E120d-M User's Guide...
If a hard disk drive that contain OS is not connected with RAID Controller, LAN card (network boot), or Fibre Channel controller, set the option ROM for that slot to Disabled. Refer to Chapter 2 (1. System BIOS) in "Maintenance Guide" for how to specify it. Express5800/E120d-M User's Guide...
<Example> x4 socket can connect with x1 and x4 cards, but not x8 card. * For details of functions of each card, refer to the Technical Guide. * The card performance described in the parentheses after the Product name indicates the maximum operation performance of the card. Express5800/E120d-M User's Guide...
When installing the card, position the terminal part of the PCI card to the PCI riser card slot and insert it. Important Do not touch the terminal part of riser cards or PCI cards and the signal pins of electric parts installed on the board. Installing boards with dirt or oil can cause malfunction. Express5800/E120d-M User's Guide...
Run SETUP and change boot order in Boot menu. Refer to Chapter 3 (2. System BIOS Setup) for how to specify it. If using the server while the card is removed, attach the blank cover that comes with the PCI riser card. Express5800/E120d-M User's Guide...
2. Remove the three screws from PCI riser card. Hold both ends of PCI riser card, and lift it straight to remove it. 3. Remove the two screws from RAID Controller, and remove PCI bracket. 4. Attach the low-profile bracket to RAID Controller with two screws you have removed in Step 3. Express5800/E120d-M User's Guide...
Page 63
RAID Controller. 7. Align the terminal pins of PCI riser card with the slot on motherboard, insert PCI riser card into the slot completely. 8. Fix the PCI riser card with the screw you removed in Step 2. Express5800/E120d-M User's Guide...
If using internal hard disk drives in RAID System with an optional RAID Controller (N8103-149/150/151) installed in the server, the SAS/SATA cable needs to be rewired. When using SAS hard disk drives, RAID Controllers must be connected. Tips 1.10.1 Connecting cables See the figure below for how to connect cables. Express5800/E120d-M User's Guide...
Do not change the mode to hibernate while building a RAID System. Important Build a Disk Array in the RAID System using hard disk drives that have the same specifications (capacity, rotational speed, and standard). Express5800/E120d-M User's Guide...
Black dot at left end of connector 3. Remove the two screws that secure the battery tray for RAID Controller, and remove the tray. 4. Mount the extra battery to the tray and secure it with three screws. Express5800/E120d-M User's Guide...
5. Install the battery tray for RAID Controller to the server chassis and secure it with two screws you removed in Step 3. 6. Connect the cable of extra battery to RAID Controller. Route the cable along the side of chassis. 1.11.3 Removal For removing the battery for the RAID Controller, reverse the installation procedure. Express5800/E120d-M User's Guide...
Important Use hard disk drives specified by NEC. Installing a third-party hard disk drive might cause a failure of the server as well as the hard disk drive. Note the following precautions to install hard disk drives.
The server provides 4 bays. Install hard disk drives in ascending port number order. 3. Remove the dummy trays. Dummy trays are installed in all bays except for bay 0. Note Keep the dummy trays for future use. 4. Unlock the handle of the tray. Express5800/E120d-M User's Guide...
Page 70
7. Turn on the server, run SETUP utility, and then specify the boot order from the Boot menu. For details about the Boot menu, refer to Chapter 2 (1.2.5 Boot) in "Maintenance Guide". The stored boot order is cleared when a hard disk drive is added. Tips Express5800/E120d-M User's Guide...
If you transfer or dispose of the removed hard disk drive, erase the user data completely by referring to Chapter 1 (1. Transfer, Movement, and Disposal) in “Maintenance Guide”. Important NEC assumes no liability for data leakage should the product be transferred to a third party without erasing the data. Note If you need to remove a hard disk drive due to a failure, check the slot with its DISK LED lit in amber.
Refer to Chapter 3 (2. System BIOS Setup), change parameters as shown below, save the settings and exit from SETUP. Server Power Control Configuration Cold Redundant Mode Enabled Run SETUP again, and check if the status of Cold Redundant Mode shows Enabled in Server menu. Express5800/E120d-M User's Guide...
2. Disconnect the AC power cord from the failed power supply unit. 3. Push the lever of the failed power supply unit toward inside, and pull the power supply unit while holding the handle. 4. Insert the new power supply unit until it is locked with clicking sound. Express5800/E120d-M User's Guide...
Page 74
Refer to Chapter 3 (1. POST Error Message) in the Maintenance Guide for details on the error messages. If the AC POWER LEDs are off, reinstall the power supply units. If the same error message still appears, contact your service representative. Express5800/E120d-M User's Guide...
Do not leave more than one device being pulled out from the rack. Do not provide the wiring for the server to exceed the rating of the power supply. Do not use in the environment where corrosive gas is generated. Express5800/E120d-M User's Guide...
Page 76
Place where the power cord of the server must be connected to an AC outlet that shares the outlet of another device with large power consumption Place near equipment that generates power noise (e.g., contact spark at power-on/power-off of commercial power supply through a relay). Environment where operation of the server is not guaranteed Express5800/E120d-M User's Guide...
Review airflow in the rack and room and take sufficient measures so that the internal temperature will not exceed the operational temperature during operation. Air enters the server from the front and exits from the rear. Express5800/E120d-M User's Guide...
Page 78
The height of rails mounted on left and right sides must be level. Push Important Confirm that the rails are securely locked so that they will not fall off. Although the rail assembly may be somewhat unsteady, it is not defective. Tips Express5800/E120d-M User's Guide...
Page 79
(1) Installation Mount the server to a rack in the following procedure. Important Always install the server with three or more persons. 1. Push the server into rack, and secure it with screws on left and right sides. Express5800/E120d-M User's Guide...
Page 80
1. Refer to Chapter 2 (2.1.2 Installing the server to the rack or removing it from the rack – Removal(2) Removal) to remove the server from the rack. 2. While pressing the lever on rail, push the rail toward inside of the rack, then remove it. Express5800/E120d-M User's Guide...
Insert the power plug into the outlet as far as it goes. Use only the specified power cord Do not connect or disconnect the interface cable with the power plugged in the outlet. Use only the specified interface cable Express5800/E120d-M User's Guide...
Page 82
Ports for data transmission refer to the next section. transmission REAR Management 100BASE-TX/ LAN port 10BASE-T Device with serial interface Hub / switching hub A leased line cannot be directly connected to the serial port connector. Tips Express5800/E120d-M User's Guide...
To change the settings, select Server and then AC-LINK in the BIOS setup utility, and change the displayed parameters. Select Power On to perform automatic operations by using the UPS. For details, refer to Chapter 2 (1. System BIOS) in "Maintenance Guide". Express5800/E120d-M User's Guide...
EXPRESSSCOPE Engine 3 provides useful features through the Baseboard Management Controller (BMC). 4. EXPRESSBUILDER EXPRESSBUILDER helps you to maintain the server. 5. Installing Software Components Describes the installation of bundled software. 6. Turning off the Server Turn off power when not using the server. Express5800/E120d-M User's Guide...
Do not connect or disconnect USB device while POST is running. POWER switch While the logo is being displayed, the self-diagnostic program (POST) runs and diagnoses the hardware. For details, refer to Chapter 3 (1.1.1 POST sequence). Express5800/E120d-M User's Guide...
Run BIOS Setup Utility (SETUP). For information on the SETUP, refer to Chapter 2 (1. System BIOS) in "Maintenance Guide". <F4> key: Run Offline Tools. For information on Offline Tools, refer to Chapter 1 (9. Offline Tools) in "Maintenance Guide". <F12> key: Boot from network. Express5800/E120d-M User's Guide...
Chapter 3 (1. POST Error Message) in "Maintenance Guide". Note Take notes on the indication displayed on display unit before consulting with your sales representative. Alarm messages are useful information for maintenance. Express5800/E120d-M User's Guide...
To exit SETUP without saving parameters, select Save & Exit Discard Changes and Exit. To restore the default value, select Save & Exit Load Setup Defaults. Tips (The default value might be different from the factory setting.) Express5800/E120d-M User's Guide...
Press this key to display help information. If you need help using the SETUP, press this key. Press the <Esc> key to go back to the original screen. <F2> key If you press this key, the following window appears. If you select Yes, the previous parameter(s) are restored. Load Previous Values? [Yes] Express5800/E120d-M User's Guide...
Page 90
Load Setup Defaults? [Yes] <F4> key If you press this key, the following window appears. If you select Yes, the parameter you configured is saved and SETUP closes. Save configuration and exit? [Yes] Express5800/E120d-M User's Guide...
If it is turned off by using Configuration AC-LINK Last State POWER switch, leave it OFF even when UPS supplies power. Server Power Control Configuration Keep the power OFF even AC-LINK Stay off when UPS supplies power. Express5800/E120d-M User's Guide...
Page 92
If you wish to exit without saving the changed parameters, select Save & Exit Discard Changes and then and Exit. Or if you wish to restore the setting to default values, select Save & Exit Load Setup Defaults. and then (The default value might be different from the factory setting.) Express5800/E120d-M User's Guide...
3. The keyboard selection screen appears. Select your keyboard type. After that, the Off-line TOOL MENU screen appears. On this screen, specify the network settings for EXPRESSSCOPE Engine 3. 4. When the Off-line TOOL MENU appears, select BMC Configuration, BMC Configuration, Network, and then Property. Express5800/E120d-M User's Guide...
Page 94
6. Connect the LAN cable to the management LAN connector in order to connect to the network. It will be available for use if you access EXPRESSSCOPE Engine 3 via Web browser from management PC according to the setting. Express5800/E120d-M User's Guide...
To use this feature, select Os (Windows reinstallation) installation on the menu after boot. Bundled software Stores various bundled software (such as NEC ESMPRO Agent). Maintenance Diagnoses your server system. To use this feature, select Tool menu on the top menu after boot.
Installing Software Components Continue to install software components such as OS. Refer to the following document and follow instructions. Installation Guide (Windows) Hibernate function of Windows Server cannot be used. Do not set Hibernate at Windows Tips shutdown. Express5800/E120d-M User's Guide...
4. AC power of server module is turned off only if it is removed from module enclosure. Important If you removed a server module from module enclosure, wait at least 30 seconds before insert it again into enclosure. Express5800/E120d-M User's Guide...
Prepare at least one external DVD-ROM per system for maintenance and OS reinstallation purposes. Prepare this if required. For the principal uses of a Flash FDD, refer to the notes on Flash FDD in the Maintenance Guide. Express5800/E120d-M User's Guide...
Peripheral Device (Controller) Peripheral Device (Controller) System timer – Numeric data processor – COM 2 serial port – COM 1 serial port – – – – SATA Real-time clock – – – – – – Express5800/E120d-M User's Guide...
Need help?
Do you have a question about the Express5800/E120d-M and is the answer not in the manual?