The drain saddle valve should fit most standard drain pipe. It
should be installed above the trap and on the horizontal pipe
(1) or vertical pipe (2).
DON'T put on position (3), (4), or blue section
Align the drilled hole in the drain pipe with the drain saddle
using a drill bit or narrow screwdriver

STEP 5: SYSTEM START-UP

1. Make sure all tubing are not kinked.
2. After the water supply tubing, drain tubing and pure water tubing are connected, turn cold water supply main
valve on slowly. Also turn input ball valve ON. Turn on pure water output. When the system is pressurized,
check for leaks. If a leak is found, tighten the connection.
3. Wait 5 minutes, the water should start dripping out of the pure water output, and then wait 10 more minutes to
allow water to flow through the system, and air inside the system can be purged.
4. Let pure water drain out for about 1 gallon before start using the water.
5. Job Well Done!
NOTE: Check for leaks daily for the first week after installation.