Installation Kit; Recommended Tools List; Operating Parameter - WaterGeneral RD-322 Installation & Service Manual

6-stage ro+di system, 260 gpd, single output reverse osmosis + di water systems
Table of Contents

Advertisement

Thank you for choosing Watergeneral Reverse Osmosis Water Systems. You now own a superb Reverse Osmosis (RO) +
Deionization (DI) system that effectively reduce most contaminants, organic and inorganic compound, unwanted taste and
odor from tap water. It is designed to transform your tap water into distill water.
Read carefully and follow the instruction in this manual before proceeding with actual installation. Failure to do so could
result in personal injury or damage to the equipment or other properties. Be sure to follow any special plumbing codes in
your area.
CHECK LIST:
1. Reverse Osmosis+DI Unit
2. for (RD-167) which includes water storage tank, 4 gallon outside volume (holds 3.2 gallons @60psi)
3. Installation kit consists tank ball valve, drain saddle valve, feed water adapter, feed water needle valve, faucet
assembly(for RD-167) , tubing, tube inserts
4. Installation manual

RECOMMENDED TOOLS LIST

Variable speed drill
5/8, 9/16 open-end wrench, or adjustable wrench, pliers
Utility knife, or scissor

OPERATING PARAMETER

Working pressure: 40 to 80 psi feed water pressure required. If input pressure is below 40 psi, a booster pump or a
permeate pump is needed. We have a RO system with built-in permeate pumps, and we also carry booster pumps.
If the input water pressure is above 80 psi (you must use a pressure regulator to step down the pressure). We
also carry small pressure regulators just for the RO system.
Working temperature: 100 ~ 40 deg. F ( 37 ~ 4 deg. C )
If feed water has hardness level above 300 ppm, we recommend putting a water softener prior to the RO system.
If feed water has iron, rust problem, we recommend putting an iron filter prior to the RO system.
If feed water has bacteria problem, we recommend putting an ultra violet sterilizing system prior to RO system.
WARNING:
Do not use this RO+DI system alone to treat water with bacteria problem or water source with unknown
quality.
WARNING:
Do not connect HOT water source to this unit.
WARNING:
Incorrect installation will VOID the warranty.
WARNING:
Input pressure must not exceed 80 psi. Pressure regulator must be installed to reduce pressure.

INSTALLATION KIT:

1. Drain saddle clamp
2. ¼" tubing
3. Bottom filter housing wrench
4. ½" feed water adapter
5. garden hose adapter, 3/4H x 1/4" tube
6. chrome ball valve for water supply
7. side-mount float valve
8. Ball valve, ON/OFF 1/4"
1/8" 1/4", 7/16", 1/2", and 5/8" drill bit
Phillips screwdriver
Teflon tape