Installation/Care/Use Manual
Semi-Recessed Wall Mount
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR
INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER
APPLICABLE CODES. After installation, leave these instructions inside the fountain
for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED COP-
1/4" O.D. TUBE
PER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
FIG. 1
11
SEE FIG. 3
IMPORTANT
IMPORTANT! INSTALLER PLEASE NOTE.
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
EDFP19C*B
Fountain with FLEXI-GUARD
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A
A
FIG. 2
Page 1
SEE FIG. 4
TUBE IS SECURED
TUBE IS SECURED
PUSH IN COLLET
PUSH IN COLLET
IN POSITION
IN POSITION
TO RELEASE TUBE
TO RELEASE TUBE
B
B
C
C
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
98655C (Rev. B - 08/16)
®

Advertisement

loading

Summary of Contents for Elkay EDFP19C series

  • Page 1 EDFP19C*B Installation/Care/Use Manual Semi-Recessed Wall Mount Fountain with FLEXI-GUARD ® SEE FIG. 4 SEE FIG. 3 Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 EDFP19C*B FIG. 3 98655C (Rev. B - 08/16) Page 2...
  • Page 3: Installation Instructions

    EDFP19C*B INSTALLATION INSTRUCTIONS 1. Connecting lines to be unplated copper and thoroughly flushed to remove all foreign matter before connection to fountain. 2. Make water supply connections from service stop to the 3/8” O.D. unplated copper tube coming out of the strainer. Turn on water supply and check for leaks. Newly installed water supply line should be insulated after leak check is completed.
  • Page 4 SEE FIG. 4 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 98655C (Rev. B - 08/16) Page 4...