1. Installation

1.2 Connection to gas supply
Installation instructions
The oven should be installed and commissioned by qualified technicians in compliance
with current regulations and legislation.
Gas appliances, electrical connections and rooms where the appliance is to be sited
must comply with current regulations and legislation.
The air requirement of the burners is 2 m3/h per kW of power installed.
Premises open to the public must comply with accident prevention laws and fire safety
regulations. A flexible metal hose can be used to connect the appliance to the gas sup-
ply; make sure you fit an approved tap in a point that is easy to reach.
Make sure that the flexible hose is not twisted or over-stretched or in contact with parts
of the oven subject to overheating.
Use locking clamps complying with installation regulations.
Checks to be carried out prior to installation.
Check the label on the left-hand panel of the oven to make sure that the appliance has
been set for the type of gas on your premises.
Check the label to make sure that the capacity of the gas pressure reducer is adequate
for the supply of the appliance.
Do not insert section reducers between the reducer and the appliance.
We recommend fitting a gas filter between the tap and pressure regulator to ensure
perfect performance.
4
(for gas ovens only)
The oven is factory set for the type of gas spe-
cified in the order.
The label attached to the appliance indicates
which type of gas the oven has been set for.
During testing, the gas produced throu-
gh combustion (CO2 and CO) should be
analysed and the nominal heat rating
should be measured to ensure that the
burners have been correctly calibrated
for the type of installation required.
Data collected should be written down and in-
cluded in the technical documentation of the
appliance.
1. Installation
Use and maintenance manual
Connect the oven to the gas supply using a special R 1/2"
hose with an internal section of at least 16 mm.
Connection to gas supply must be carried out using rigid or
flexible metal pipes. Use taps or gates with an internal diame-
ter that is greater than that of the hose.
After connecting the appliance to the gas supply make sure
that there are no leaks from joints or connections. You can
test for leaks by using soapy water or foaming agent for leak
detection.
Gas ovens should be inspected in compliance with spe-
cific regulations once a year by an authorised techni-
cian who will analyse combusted gases and check no-
minal heat rating.
The appliance can work correctly only when gas pres-
sure keeps within specific values for each gas type (see
table).
If the pressure falls outside these values, it will not be possible
to achieve optimum functioning of the appliance and for it to
be installed correctly. Should this happen, call a technician to
check your gas mains (ducts, gates and eventually pressure
reducers) then, if necessary, contact your gas provider.