A damaged • ME523 - ME5232 - MME523 appliance must never be installed and commissioned; if Do not position other heat sources like, fryers or in doubt, immediately contact the after-sales technical hotplates, near the oven.
1. Installation 1. Installation 1.2 Connection to gas supply (for gas ovens only) The oven is factory set for the type of gas spe- Connect the oven to the gas supply using a special R 1/2” cified in the order. hose with an internal section of at least 16 mm.
1. Installation 1. Installation 1.3 Control of Gas Pressure (for gas ovens only) 1.5 Electric connection Check that the installed nozzles are correct for the type and pressure of supplied gas. If you need to change the The electric system, as prescribed and specified by the Standard in force, must be nozzles, read the following paragraph.
1. Installation 1. Installation 1.6 Fume discharge 1.8 Switching on oven and testing (for gas ovens only) Ovens should only be installed in adequately ventilated rooms in compliance with installation regulations. Before switching on the oven, carefully check that all systems and installation of the appliance are in compliance with current laws and with the technical and safety guidelines in this manual.
2. Use instruction (combi-ovens) 2. Use instructions (combi-ovens) 2.2 Control panel 2.1 Preliminary information The appliance has been designed to cook food in Cooking mode / OFF knob closed premises and must only be used for this pur- OFF position pose: any other use must, be avoided and conside- red improper &...
2. Use instruction (combi-ovens) 2. Use instruction (combi-ovens) 2.3 Convection cooking 2.4 Steaming Choose steaming mode by turning the M1 knob to Choose the convection cooking mode by turning the clockwise to position I3. M1 knob clockwise to position I2. Then choose the cooking temperature by turning the Then choose the cooking temperature by turning the M2 knob to the desired temperature.
Page 8
2. Use instruction (combi-ovens) 2. Use instruction (combi-ovens) 2.5 Convection/steam mixed cooking 2.6 Humidity drainig valve Choose the convection/steam mixed cooking by tur- The humidity draining valve has the task of expelling ning the M1 knob to clockwise to position I4. humidity formed inside the cooking chamber during the cooking.
2. Use instruction 3. Maintenance 2.10 Other versions 3.1 Cleaning ELECTROMECHANICAL CONTROL WITH HUMIDIFIER AND TWO FAN SPEED At the end of a working day, clean the equipment, both for hygienic reasons and to avoid malfunctionings. In this version, the oven always works in convection mode. It is possible to add moisture in the The oven must never be cleaned using direct or high pressure water jets.
Switch-off the oven and wait for the motor thermal protection to The fan stops during automatically reset. functioning 5.1 ME523 - ME5232 - MME523 Ensure that the cooling inlets are not obstructed. Should the problem repeat, contact the after-sales assistance. Use lamps resistant to heat.
5. Data sheet 5. Data sheet 5.6 MG5 - MG52 - MMG52 TECHNICAL DATA Dimensions: 870x748x783 mm Volume: 0,50m Ø 50 Weigth: 80 Kg Chamber capacity: 7x(GN1/1 - 600x400) Distance between layers: 74 mm Net dimension of oven cavity: 645x600x450 mm (LxHxP) Oven cavity power: 9 kW or 12 kW (..X) Total electric power: 9,6 kW or 12,6 kW (..X) Power supplay voltage: 3N 400V AC-50Hz...
Page 13
5. Data sheet 5. Data sheet 5.9 MR3 - MR32 - MR31 - MR321 TECHNICAL DATA Dimensions: 870x748x783 mm Volume: 0,50m Ø 50 Weigth: 80 Kg Chamber capacity: 7x(GN1/1 - 600x400) Distance between layers: 74 mm Net dimension of oven cavity: 645x600x450 mm (LxHxP) Oven cavity power: 9 kW Total electric power: 9,3 kW Power supplay voltage: 3N 400V AC-50Hz...