YPP6300 Pulse Input Rate/Totalizer
Pulse, Open Collector, NPN, PNP, TTL, Switch Contact,
Sine Wave (Coil), Square Wave Inputs
Gate Function for Rate Display of Slow Pulse Rates
NEMA 4X, IP65 Front
Universal 85-265 VAC, or 12/24 VDC Input Power Models
Large Dual-Line 6-Digit Display, 0.60" & 0.46"
Isolated 24 VDC @ 200 mA Transmitter Power Supply
Programmable Displays & Function Keys
Sunlight Readable Display Models
Rate Displayed as Units per Second, Minute, Hour, or Day
Total, Grand Total or Non-Resettable Grand Total
9-Digit Totalizer with Total Overflow Feature
K-Factor Calibration or Scale with up to 32-Point Linearization
2 or 4 Relays + Isolated 4-20 mA Output for Rate or Total
External 4-Relays & Digital I/O Expansion Modules
USB, RS-232 & RS-485 Serial Communication Options
®
Modbus
RTU Communication Protocol Standard
PROPLUS
Free
and Programming
Instruction Manual
Software for Operation, Monitoring,
2 Dart Road • Newnan, Georgia 30265
770-253-7000 • 800-888-6400
Fax: 770-251-2088 • www.yokogawa-usa.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YPP6300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA YPP6300

  • Page 1 YPP6300 Pulse Input Rate/Totalizer Instruction Manual  Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave Inputs  Gate Function for Rate Display of Slow Pulse Rates  NEMA 4X, IP65 Front  Universal 85-265 VAC, or 12/24 VDC Input Power Models ...
  • Page 2: Limited Warranty

    Anyone using this product for such applications does so at his/her own risk. Yokogawa Corporation of America shall not be held liable for damages resulting from such improper use.
  • Page 3: Table Of Contents

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Table of Contents INTRODUCTION ------------------------------------------------------------- 7 ORDERING INFORMATION ---------------------------------------------- 8 SPECIFICATIONS ----------------------------------------------------------- 9 General ------------------------------------------------------------------------------- 9 Rate Input ------------------------------------------------------------------------- 10 Rate/Totalizer -------------------------------------------------------------------- 11 Relays ------------------------------------------------------------------------------ 12 Isolated 4-20 mA Transmitter Output ------------------------------------ 13 ®...
  • Page 4 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting Up the Rate/Totalizer Meter (setup) --------------------------- 37 Setting the Input Signal (Input) ------------------------------------------ 38 Setting the Totalizer Features (total) ---------------------------------- 38 Setting the Decimal Point (dEc pt) -------------------------------------- 38 Programming the Rate/Totalizer (prog) -------------------------------- 39 K-Factor Calibration (Factor) ----------------------------------------- 40 Multi-Point Calibration &...
  • Page 5 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Scaling the 4-20 mA Analog Output (Aout) ---------------------------- 66 Setting Up the Password (pass) ------------------------------------------- 67 Protecting or Locking the Meter ------------------------------------------- 67 Total Reset Password & Non-Resettable Total ----------------------- 68 Making Changes to a Password Protected Meter -------------------- 69...
  • Page 6 Figure 4: Jumper Configuration for 12/24 VDC Power ..... 19 Figure 5: Transmitter Supply Voltage Selection ....... 20 Figure 6: Connector Labeling for Fully Loaded YPP6300 ....21 Figure 7: Power Connections ............. 21 Figure 8: Flowmeter Powered by Internal Power Supply ....22 Figure 9: Flowmeter Powered by External Supply ......
  • Page 7: Introduction

    24 VDC power supply is included with the 4-20 mA output option. A fully loaded YPP6300 pulse rate/totalizer meter has the following: four SPDT relays, 4-20 mA output, and two 24 VDC power supplies. The YPP6300 capabilities may be enhanced by adding the following external expansion modules: four SPST relays (creating an eight-relay rate/totalizer), two digital I/O modules with four inputs and four outputs each, and RS-232 or RS-485 communication adapters.
  • Page 8: Ordering Information

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual ORDERING INFORMATION Standard Models 85-265 VAC 12/24 VDC Options Installed Model Model YPP6300-6R0 YPP6300-7R0 No options YPP 6300-6R2 YPP6300-7R2 2 relays YPP 6300-6R3 YPP6300-7R3 4-20 mA output YPP 6300-6R4 YPP6300-7R4 4 relays YPP 6300-6R5 YPP6300-7R5 2 relays &...
  • Page 9: Specifications

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual SPECIFICATIONS Except where noted all specifications apply to operation at +25°C. General DISPLAY Main display: 0.6" (15 mm) high, red LEDs Second display: 0.46" (12 mm) high, red LEDs 6 digits: each (-99999 to 999999), with lead zero blanking.
  • Page 10: Rate Input

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual OVERVOLTAGE Installation Overvoltage Category II: CATEGORY Local level with smaller transient overvoltages than Installation Overvoltage Category III. ENVIRONMENTAL Operating temperature range: -40 to 65°C Storage temperature range: -40 to 85°C Relative humidity: 0 to 90% non-condensing...
  • Page 11: Rate/Totalizer

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual DECIMAL POINT Up to five decimal places or none: d. d dddd, d. d ddd, d. d dd, d. d d, d. d , dddddd CALIBRATION May be calibrated using K-factor, internal calibration, or by applying an external calibration signal.
  • Page 12: Relays

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual TOTAL Program total reset for automatic with 0.1 second delay and OVERFLOW set point 1 for 999,999 OVERRIDE TOTALIZER Up to eight, user selectable under setup menu. Any set PRESETS point can be assigned to total and may be programmed anywhere in the range of the meter for total alarm indication.
  • Page 13: Isolated 4-20 Ma Transmitter Output

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual RELAY RESET User selectable via front panel buttons, digital inputs, or PC Automatic reset only (non-latching), when the input passes the reset point or total is reset to zero. Automatic + manual reset at any time (non-latching)
  • Page 14: Modbus ® Rtu Serial Communications

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual ® Modbus RTU Serial Communications SLAVE ID 1 – 247 (Meter address) BAUD RATE 300 - 19,200 bps TRANSMIT Programmable between 0 and 199 ms TIME DELAY DATA 8 bit (1 start bit, 1 or 2 stop bits)
  • Page 15: Compliance Information

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual COMPLIANCE INFORMATION Safety UL & c-UL LISTED USA & Canada UL 508 Industrial Control Equipment UL FILE NUMBER E348677 FRONT PANEL UL Type 4X, NEMA 4X, IP65; panel gasket provided LOW VOLTAGE EN 61010-1:2001...
  • Page 16: Safety Information

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Note: Testing was conducted on YPP6300 meters installed through the covers of grounded metal enclosures with cable shields grounded at the point of entry representing installations designed to optimize EMC performance. Declaration of Conformity available at www.yokogawa-usa.com...
  • Page 17: Installation

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual INSTALLATION There is no need to remove the meter from its case to complete the installation, wiring, and setup of the meter for most applications. Instructions are provided for setting up a 12/24 VDC powered meter to operate from 12 VDC and for changing the transmitter power supply to output 5 or 10 VDC instead of 24 VDC, see page 19.
  • Page 18: Figure 2: Meter Dimensions - Side View

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Dimensions Figure 2: Meter Dimensions - Side View Figure 3: Meter Dimensions - Top View...
  • Page 19: Configuration For 12 Or 24 Vdc Power Option

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Configuration for 12 or 24 VDC Power Option Do not exceed voltage rating of the selected configuration. Warning! Meters equipped with the 12/24 VDC power option are shipped from the factory ready to operate from 24 VDC.
  • Page 20: Transmitter Supply Voltage Selection (P+, P-)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Transmitter Supply Voltage Selection (P+, P-) All meters, including models equipped with the 12/24 VDC power option, are shipped from the factory configured to provide 24 VDC power for the transmitter or sensor.
  • Page 21: Connectors Labeling

    M-LINK connector. Otherwise damage will occur to the Warning! equipment and the meter. Figure 6: Connector Labeling for Fully Loaded YPP6300 Power Connections Power connections are made to a two-terminal connector labeled POWER on Figure 6. The meter will operate regardless of DC polarity connection.
  • Page 22: Signal Connections

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Signal Connections Signal connections are made to a five-terminal connector labeled SIGNAL on Figure 6. The COM (common) terminal is the return for the input signals. The following figures show examples of signal connections.
  • Page 23 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual INPUT SIGNAL +5 V 4.7 k-ohm Internal pull-up PNP NPN LEVEL TYPE SENSOR Figure 11: NPN open Collector Input INPUT SIGNAL 4.7 k-ohm Internal pull-down PNP NPN LEVEL TYPE SENSOR Figure 12: PNP Sensor Powered by Internal Supply...
  • Page 24: Modbus Rtu Serial Communications

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Modbus RTU Serial Communications Serial communications connection is made to an RJ45 connector labeled M-LINK on Figure 6. For interfacing to the PROPLUS use the YPPA1232 for RS-232, the YPPA1485 for RS-485, or the YPPA8008 for USB. The same port is used for interfacing with all expansion modules (e.g.
  • Page 25: Switching Inductive Loads

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Switching Inductive Loads The use of suppressors (snubbers) is strongly recommended when switching inductive loads to prevent disrupting the microprocessor’s operation. The suppressors also prolong the life of the relay contacts. Suppression can be obtained with resistor-capacitor (RC) networks assembled by the user or purchased as complete assemblies.
  • Page 26: 4-20 Ma Output Connections

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual 4-20 mA Output Connections Connections for the 4-20 mA transmitter output are made to the connector terminals labeled MA OUT. The 4-20 mA output may be powered internally or from an external power supply.
  • Page 27: External Relay & Digital I/O Connections

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual External Relay & Digital I/O Connections The relay and digital I/O expansion modules YPPA1004 & YPPA1044 are connected to the meter using the CAT5 cable provided with each module. The two RJ45 connectors on the expansion modules are identical and interchangeable;...
  • Page 28: Interlock Relay Feature

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual DI 1-4 DO 1-4 5 VDC Figure 17: Digital I/O Module Connections Interlock Relay Feature As the name implies, the interlock relay feature reassigns one, or more, alarm/control relays for use as interlock relay(s). Interlock contact(s) are wired to digital input(s) and trigger the interlock relay.
  • Page 29: Setup And Programming

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual SETUP AND PROGRAMMING  The meter has been factory calibrated to read input frequency in Hz (pulses/sec). The calibration equipment is certified to NIST standards.  Use the K-Factor menu to match the rate/totalizer with a flowmeter’s k-factor (pulse/unit of measure).
  • Page 30: Front Panel Buttons And Status Led Indicators

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Front Panel Buttons and Status LED Indicators Button Description Status Symbol Menu Alarm 1 – 8 indicator Right arrow/F1 Rate indicator Up arrow/F2 Total Enter/F3 Grand Total indicator Note: Total overflow ▲ indicator...
  • Page 31: Display Functions And Messages

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Functions and Messages The meter displays various functions and messages during setup, programming, and operation. The following table shows the main menu functions and messages in the order they appear in the menu.
  • Page 32 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Input 2 Calibrate input 2 signal or program input 2 Inp 2 value (up to 32 points) Display 2 Program display 2 value (up to 32 points) Dis 2...
  • Page 33 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Sampling Set relay for sampling operation Sanmpl Disable relay and front panel status LED (Select Off to enable Interlock feature) Set 1 Program set point 1 Set 1 Reset 1...
  • Page 34 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Grand total Program grand total time base GT tb time base Grand total Program grand total conversion factor GT CF conversion factor Program grand total reset mode: auto or...
  • Page 35: Main Menu

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Main Menu The main menu consists of the most commonly used functions: Reset, Control, Setup , and Password .  Press Menu button to enter Programming Mode then press the Up arrow button to scroll through the main menu.
  • Page 36: Setting Numeric Values

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting Numeric Values The numeric values are set using the Right and Up arrow buttons. Press Right arrow to select next digit and Up arrow to increment digit value. The digit being changed is displayed brighter than the rest.
  • Page 37: Model Ypp6300 Pulse Input Rate/Totalizer Instruction Manual

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting Up the Rate/Totalizer Meter (setup) The Setup menu is used to select: Enable or disable totalizer features Decimal point position Display parameter and intensity Relay operation 4-20 mA analog output scaling Press the Enter button to access any menu or press Up arrow button to scroll through choices.
  • Page 38: Setting The Input Signal (Input)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting the Input Signal (Input) There are two switches, located to the right of the input connector, which must be configured according to the input level and type. Jumper J4 located inside the meter, behind the input signal connector, is used to select the excitation voltage (24 V*, 10 V or 5 V) which is supplied to the P+ and P- wiring terminals.
  • Page 39: Programming The Rate/Totalizer (Prog)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Programming the Rate/Totalizer (prog) It is very important that one reads the following information before programming the meter:  The meter has been factory calibrated to read input frequency in Hz (pulses/sec). The calibration equipment is certified to NIST standards.
  • Page 40: K-Factor Calibration (Factor)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual K-Factor Calibration (Factor) The meter may be calibrated using the K-Factor function. Most flowmeter manufacturers provide this information with the device. Enter the K-Factor ( Factor ) menu and select the decimal point with highest resolution possible and program the k-factor value ( i.e.
  • Page 41: Proplus Software

    PROPLUS Software PROPLUS The meter can also be programmed using the PC-based software available for free download at www.yokogawa-usa.com. PROPLUS Data logging for one meter at the time is available with software. More advanced data acquisition may be accomplished by using any Modbus RTU compliant software.
  • Page 42: Scaling The Meter (Scale)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Scaling the Meter (SCALE) The pulse inputs can be scaled to display the process variable in engineering units. A signal source is not needed to scale the meter; simply program the inputs and corresponding display values.
  • Page 43: Gate Function (Gate)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Error Message (Error) An error message indicates that the calibration or scaling process was not successful. After the error message is displayed, the meter reverts to input 2 during calibration or scaling, allowing the appropriate input signal to be applied or programmed.
  • Page 44: Contact De-Bounce Filter (Filter)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Gate Settings Slow Pulse Rate Low Gate* (sec) High Gate (sec) Min Freq** (Hz) 0.5000 10.0 0.1000 20.0 0.0500 100.0 0.0100 200.0 0.0050 400.0 0.0025 800.0 0.0012 999.9 0.0010 *The low gate setting corresponds to the display update rate and is used to stabilize the display reading with a fluctuating signal.
  • Page 45: Time Base, Total Conversion Factor & Total Reset

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Time Base, Total Conversion Factor & Total Reset The time base, total conversion factor, and total reset menus are located in the Program menu. The total and grand total have their own independent settings. This...
  • Page 46: Calibrating The Meter With External Source (Cal)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Calibrating the Meter with External Source (Cal) To scale the meter without a signal source refer to K-Factor Calibration ( Factor ) on page 40 or Scaling the Meter ( SCALE ) on page 42...
  • Page 47: Setting The Display Parameter & Intensity (Dsplay)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting the Display Parameter & Intensity (dsplay) The main display ( Big ) can be programmed to display: Rate value Total or grand total Relay set points Max & min values Modbus input...
  • Page 48: Display Setup Menu

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Setup Menu After setting up the input and the display, press the Menu button to exit programming and skip the rest of the setup menu. Press the Menu button again and the Up arrow to reach the Program menu and complete...
  • Page 49: Character Set For Engineering Units Display (D Unit)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Character Set for Engineering Units Display (d unit) The small display can be programmed to show engineering units or custom legends using the following 7-segment character set: Display Character Display Character Space Degree *Degree symbol (special non-ASCII character used) The letters “m”...
  • Page 50: Setting The Relay Operation (Relay)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting the Relay Operation (relay) This menu is used to set up the operation of the relays. CAUTION! During setup, the relays do not follow the input and they will remain in the state found prior to entering the Relay menu.
  • Page 51: Relay Assignment (Assign)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual relay setup Assign Failsf delay relay relay relay relay Asign1 A s s i g n r l y 1 F a i l s f delay rly 1 F l s 1...
  • Page 52: Setting The Relay Action

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting the Relay Action Operation of the relays is programmed in the Action menu. The relays may be set up for any of the following modes of operation: Automatic reset (non-latching) Automatic + manual reset at any time (non-latching)
  • Page 53: Programming Set And Reset Points

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Programming Set and Reset Points High alarm indication: program set point above reset point. Low alarm indication: program set point below reset point. The deadband is determined by the difference between set and reset points.
  • Page 54: Relay And Alarm Operation Diagrams

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Relay and Alarm Operation Diagrams The following graphs illustrate the operation of the relays, status LEDs, and ACK button. High Alarm Operation (Set > Reset) Input Reset de-energized energized Relay Automatic (non-latching) Relay...
  • Page 55: Low Alarm Operation (Set < Reset)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Low Alarm Operation (Set < Reset) Input Reset de-energized energized Relay Automatic (non-latching) Relay pressed Automatic or Manual (non-latching) Relay pressed Manual (latching) Relay pressed Manual only after passing above Reset (latching with clear) For Manual reset mode, ACK can be pressed anytime to turn "off"...
  • Page 56: High Alarm With Fail-Safe Operation (Set > Reset)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual High Alarm with Fail-Safe Operation (Set > Reset) Input Reset de-energized energized Relay Automatic (non-latching) Relay pressed Automatic or Manual (non-latching) Relay pressed Manual (latching) Relay pressed Manual only after passing below Reset (latching with clear) Note: Relay coil is energized in non-alarm condition.
  • Page 57: Low Alarm With Fail-Safe Operation (Set < Reset)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Low Alarm with Fail-Safe Operation (Set < Reset) Input Reset de-energized energized Relay Automatic (non-latching) Relay pressed Automatic or Manual (non-latching) Relay pressed Manual (latching) Relay pressed Manual only after passing above Reset (latching with clear) Note: Relay coil is energized in non-alarm condition.
  • Page 58: Alternation Control Operation

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual...
  • Page 59: Rate Relay Sampling Operation

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Rate Relay Sampling Operation Input Reset Sample Sample Sample Time Time Time Relay When the signal crosses the set point, the relay trips and the sample time starts. After the sample time has elapsed, the relay resets. The cycle repeats every time the set point is crossed, going up for high alarms and going down for low alarms.
  • Page 60: Time Delay Operation

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Time Delay Operation The following graphs show the operation of the time delay function. Input Reset <Tdelay <Tdelay >=Tdelay Relay On Time Delay Input Reset <Tdelay <Tdelay >=Tdelay Relay Off Time Delay When the signal crosses the set point, the On time delay timer starts and the relay trips when the time delay has elapsed.
  • Page 61: Relay Operation Details

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Relay Operation Details Overview The relay capabilities of the meter expand its usefulness beyond simple indication to provide users with alarm and control functions. These capabilities include front panel alarm status LEDs as well as either 2 or 4 optional internal relays and/or 4 external relays expansion module.
  • Page 62: Front Panel Leds

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Front Panel LEDs The LEDs on the front panel provide status indication for the following: Status Status Alarm 1 Alarm 5 Alarm 2 Alarm 6 Alarm 3 Alarm 7 Alarm 4 Alarm 8 The meter is supplied with four alarm points that include front panel LEDs to indicate alarm conditions.
  • Page 63: Non-Latching Relay (Auto)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Non-Latching Relay (Auto) Automatic reset only Condition Relay Normal Alarm Ack (No effect) Normal In this application, the meter is set up for automatic reset (non-latching relay). Acknowledging the alarm while it is still present has no effect on either the LED or the relay.
  • Page 64: Latching Relay (Lt-Clr)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Latching Relay (Lt-Clr) Manual reset only after alarm condition has cleared Condition Relay Normal Alarm Ack (No effect) Normal In this application, the meter is set up for manual reset only after the signal passes the reset point (alarm condition has cleared).
  • Page 65: Setting Up The Interlock Relay (Force On) Feature

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting Up the Interlock Relay (Force On) Feature Relays 1-4 can be set up as interlock relays. To set up the relays for the interlock feature: 1. Access the Setup – Relay – Action menu and set the action to off.
  • Page 66: Scaling The 4-20 Ma Analog Output (Aout)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Scaling the 4-20 mA Analog Output (Aout) The 4-20 mA analog output can be scaled to provide a 4-20 mA signal for any display range selected. No equipment is needed to scale the analog output; simply program the display values to the corresponding mA output signal.
  • Page 67: Setting Up The Password (Pass)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Setting Up the Password (pass) The Password menu is used for programming three levels of security to prevent unauthorized changes to the programmed parameter settings and to program the non-resettable totalizer. Pass 1: Allows use of function keys and digital inputs Pass 2: Allows use of function keys, digital inputs and editing set/reset points Pass 3: Restricts all programming, function keys, and digital inputs.
  • Page 68: Total Reset Password & Non-Resettable Total

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Total Reset Password & Non-Resettable Total The total and the grand total can be password-protected to prevent unauthorized total resets. The grand total can be programmed as a non-resettable total by entering the password “050873”.
  • Page 69: Making Changes To A Password Protected Meter

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Making Changes to a Password Protected Meter If the meter is password protected, the meter will display the message Locd ( Locked ) when the Menu button is pressed. Press the Enter button while the message is being displayed and enter the correct password to gain access the menu.
  • Page 70: Advanced Features Menu

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Advanced Features Menu To simplify the setup process, functions not needed for most applications are located in the Advanced Features menu. Press and hold the Menu button for three seconds to access the advanced features of the meter.
  • Page 71: Advanced Features Menu & Display Messages

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Advanced Features Menu & Display Messages The following table shows the functions and messages of the Advanced Features menu in the order they appear in the menu. Display Parameter Action/Setting Enter Gate function menu...
  • Page 72 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting u-rang Underrange Program mA output for display underrange Program maximum mA output allowed Maximum Minimum Program minimum mA output allowed Calibrate 4-20 mA output (internal Calib Calibrate reference source used for scaling the...
  • Page 73 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Cutoff Cutoff Cutoff value Set time period T tb Total time base Total Set conversion factor T CF conversion factor Total reset Set reset method T rst Grand total Set grand total time period...
  • Page 74: Modbus Rtu Serial Communications (Serial)

    0 and 199 ms. The parity can be set to even, odd, or none with 1 or 2 stop bits. The YPP6300 can also be connected to another YPP6300 with a special YPPA1200 cable, allowing the user to copy all the settings from one...
  • Page 75: Select Menu (Select)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Select Menu (SElEct) The Select menu is used to select the signal input conditioner applied to the input (linear), low-flow cutoff, and analog output programming. The multi-point linearization is part of the linear function selection.
  • Page 76: Multi-Point Linearization (Linear)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Multi-Point Linearization (Linear) Meters are set up at the factory for linear function with 2-point linearization. Up to 32 linearization points can be selected under the linear function. The multi-point linearization can be used to linearize the display for non-linear signals.
  • Page 77: Low-Flow Cutoff (Cutoff)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Low-Flow Cutoff (CutofF) The low-flow cutoff feature allows the meter to be programmed so that the often-unsteady output from a differential pressure transmitter, at low flow rates, always displays zero on the meter.
  • Page 78: Programmable Function Keys User Menu (User)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Programmable Function Keys User Menu (user) The User menu allows the user to assign the front panel function keys F1, F2, F3 and up to eight digital inputs to access most of the menus or to activate functions immediately (e.g.
  • Page 79: Meter Copy Function (Copy)

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Meter Copy Function (Copy) The Copy function is used to copy (or clone) all the settings from one meter to other meters requiring exactly the same setup and programming ( i.e . type of input, scaling, decimal point, filter, gate, etc.).
  • Page 80 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Meter Copy or Cloning Instructions Do not connect the two meters to the same signal source while cloning. Internal calibration may Caution! be affected. Connect two meters using a YPPA1200 meter copy cable.
  • Page 81: Meter Operation

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual METER OPERATION The meter accepts pulses (e.g. ±40mV to ± 8V), square wave (0-5, 0- 12V, or 0-24V), open collector NPN, PNP, TTL, or switch contact signals and displays these signals in engineering units from -99999 to 999999.
  • Page 82: Maximum/Minimum Readings

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Maximum/Minimum Readings The max & min readings (peak & valley) reached by the process can be displayed either continuously or momentarily: Display briefly by assigning to the F1-F3 function keys or to the digital inputs in the User menu.
  • Page 83: Troubleshooting

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual TROUBLESHOOTING The rugged design and the user-friendly interface of the meter should make it unusual for the installer or operator to refer to this section of the manual. However, due to the many features and functions of the meter, it’s possible that the setup of the meter does not agree with what an...
  • Page 84: Reset Meter To Factory Defaults

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Reset Meter to Factory Defaults When the parameters have been changed in a way that is difficult to determine what’s happening, it might be better to start the setup process from the factory defaults.
  • Page 85: Factory Defaults & User Settings

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Factory Defaults & User Settings The following table shows the factory setting for most of the programmable parameters on the meter. Next to the factory setting, the user may record the new setting for the particular application.
  • Page 86 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Parameter Display Default Setting User Setting Relay 3 assignment Rate Asign3 Relay 4 assignment Rate Asign4 Relay 1 action Automatic Act 1 Relay 1 set point 100.0 Set 1 Relay 1 reset point 000.0...
  • Page 87 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Parameter Display Default Setting User Setting Source analog output Rate/process Source Overrange output 21.000 mA O-rang Underrange output u-rang 3.000 mA Maximum output 23.000 mA Minimum output 0.000 mA Slave ID (Address) Slave Id...
  • Page 88: Troubleshooting Tips

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Troubleshooting Tips Symptom Check/Action Check power at power connector No display at all Meter is password-protected, enter Not able to change setup or correct six-digit password to unlock programming, Locd is displayed Check:...
  • Page 89: Alphabetical List Of Display Functions & Messages

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Alphabetical List of Display Functions & Messages Display Parameter Action/Setting Description Enter mA output value read by milliamp 20 mA 20 mA output meter with at least 0.001 mA resolution 4 mA output...
  • Page 90 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Calibrate Calibrate 4-20 mA output (internal Calib reference source used for scaling the output) Enter Control menu Control Contrl Copy Enter copy function Copy Cutoff Cutoff value Cutoff Display high...
  • Page 91 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Digital Assign digital output 1 – 8, if expansion dO 1 modules are connected output 1 done Done Copy function completed Display set 1 Select to display set point 1 (1-8)
  • Page 92 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Input 2 Calibrate input 2 signal or program input 2 Inp 2 value (up to 32 points) Input Input Input selection Latching Set relay for latching operation (relays LatCH...
  • Page 93 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Disable relay and front panel status LED, turn relays off, program off time delay OFF 1 Disable relay and front panel status LED, turn relays off, program off time delay...
  • Page 94 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Display Parameter Action/Setting Description Reset To reset grand total Rst Gt grand total Reset high Press Enter to reset max display Rst Hi Reset Press Enter to reset max & min displays Rst HL high &...
  • Page 95: Figure 21: 1/8 Din Panel Cutout Template

    Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual Figure 21: 1/8 DIN Panel Cutout Template...
  • Page 96 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual...
  • Page 97 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual NOTES...
  • Page 98 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual NOTES...
  • Page 99 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual NOTES...
  • Page 100 Model YPP6300 Pulse Input Rate/Totalizer Instruction Manual LIM6300YK_A SFT039 Ver 2.200 & up 11/11...

Table of Contents