Nominal Data; Technical Description; Mounting Data; Storage Conditions - Ebmpapst S4D300-AP28-30 Operating Instructions Manual

Table of Contents

Advertisement

S4D300-AP28-30

3.2 Nominal data

Motor
M4D068-CF
Phase
3~
Nominal voltage [V]
230
Connection
D
Frequency [Hz]
50
Type of data definition
rfa
Valid for approval /
CE
standard
Speed [min
-1
]
1370
Power input [W]
60
Current draw [A]
0.29
Max. back pressure [Pa]
90
Max. ambient
45
temperature [°C]
ml = max. load · me = max. efficiency · rfa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations

3.3 Technical description

Leackage current
< 0,75 mA
Size
300 mm
Operation mode
S1
Direction of rotation
Counter-clockwise, seen on rotor
Mounting position
Shaft horizontal or rotor on bottom; rotor on
top on request
Humidity class
F1-2
Direction of air flow
"V"
Insulation class
"B"
Cable exit
Axial
Condensate discharge
Rotor-side
holes
Bearing motor
Ball bearing
Mass
2.4 kg
Material of blades
Sheet steel, coated in black
Material of guard grille
Steel, phosphated and coated in black
plastic
Product conforming to
EN 60335-1
standard
Surface of rotor
Coated in black
Number of blades
5
Type of protection
IP 44
Protection class
I
Approval
CCC

3.4 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products
⇒ Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
8.8
mounting screws
You can obtain additional mounting data from the product drawing if
necessary.
Item no.: 10561-5-9970 · Revision status: KM68158 · Print-out on 27.04.10 · Created by Y. Uhlmann (VM-TDO) · Page 5 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
Operating instructions
3~
3~
3~
230
400
400
D
Y
Y
60
50
60
rfa
rfa
rfa
CE
CE
CE
1540
1370
1540
75
60
75
0.26
0.17
0.15
60
90
60
40
45
40

3.5 Storage conditions

⇒ Use the device in accordance with its protection type.
Max. permissible
+ 80 °C
ambient motor temp.
(transp./ storage)
Min. permissible
- 40 °C
ambient motor temp.
(transp./storage)

Advertisement