Air Heater
PLANAR 9D
Operating Manual
ADVR.216.00.00.000 RE
(25.01.2018)

Advertisement

Table of Contents
loading

Summary of Contents for Planar PLANAR-9D-12

  • Page 1 Air Heater PLANAR 9D Operating Manual ADVR.216.00.00.000 RE (25.01.2018)
  • Page 2: Table Of Contents

    Sales department ADVERS LLC Russia, Service support 443068, Samara, Novo- Autoterm LLC Autoterm LLC Trikatas street 4, Riga, Latvia Trikatas street 4, Riga, Latvia Sadovaya street, 106 +371 20110229 +371 25529999 +7(846)263-07-97 Е-mail: E-mail: sales@autoterm- service@autoterm- www.autoterm.ru europe.com europe.com www.autoterm- To find nearest service point: europe.com https://autoterm-...
  • Page 3: Introduction

    1 Introduction This operation manual is intended to familiarize the User with salient features, operation, assembly and operating procedures for PLANAR–9D-12, PLANAR–9D-24, (hereinafter called «the heater») intended for regulated heating of various compartments of a motorized vehicles at atmospheric temperatures as low as -45°С (-113F).
  • Page 4: Safety Measures

    Table 1 3 Safety Measures 3.1 The installation of the heater and its fittings shall be performed by authorized organizations only. 3.2 The heater may only be used for the purposes specified herein. 3.3 The fuel supply line shall not be installed inside the passenger compartment or cabin of a motor vehicle.
  • Page 5: Description Of Heater Structure And Operation

    4 Description of Heater Structure and Operation The heater operates independently from the vehicle engine. The fuel and electric power supply is provided by the vehicle. See figure 4.1 for the heater wiring diagram. The heater is a self-contained heating device comprising the following: - heating device (see figure 4.2 for basic components thereof);...
  • Page 6: Heater Control Unit

    5 Heater control unit The control unit and the control panel control the heater. The control unit performs the following functions: а) initial diagnostics (serviceability check) of heater fittings during ignition, b) diagnostic of heater elements throughout operation, c) heater activation/deactivation by command from control panel; d) combustion process control;...
  • Page 7 1. View of connector (XS1, XS3, XS7, XP1, XP3, XP7) is shown from contact side (not from wires side). 2. *color of a tag on wires 3. **to buy in addition 1. Figure. 4.1- Wiring diagram...
  • Page 8 Figure 4.2 – Basic heater components...
  • Page 9: Scope Of Supply

    7 Scope of Supply See figure 7.1 for scope of supply and connection diagram of basic heater components PLANAR-9D-12, PLANAR-9D-24. Figure 7.1 – Connection diagram of basic heater components...
  • Page 10: Installation Requirements

    Installation requirements 8.1 Heater installation Install the heater according to figure 8.1. Peace of installation for the heater should be flat. Position the heater’s inlet vent in such a way to prevent absorption of vehicle/heater exhaust gas in normal operating conditions. The distance between the walls/partitions and the edge of the inlet vent shall be at least 100 mm (see figure 8.1).
  • Page 11 At installation of the heater check that its case had no contact both with a floor and with other parts of a cabin or a manned compartment. Non-performance of this requirement can lead to deformation of the heater case, jamming of the air fan and a possible overheat.
  • Page 12 Attention! At installation of a heater into the volume of vans (isothermal boxes, minibuses, etc.) the arrangement of an exhaust pipe and an air inlet on opposite boards is inadmissible. Installation of exhaust and air intake pipes through one board is correct. The distance between them has to exclude repeated absorption of exhaust gases through an air inlet (not less 200mm).
  • Page 13 Heaters of PLANAR-9D-12, PLANAR-9D-24 it is completed with the fuel pump for which mounted position has to be correspond to fig. 8.4a, i.e. ± 5 ˚ from horizontal position.
  • Page 14 Attention!!! While manufacturing a hole in a regular fuel tank of the car it is necessary to fulfill safety requirements for works with tank which was filled with combustible and explosive fuel. 1- fuel supply intake 4- washer 8 2- nut M8 5- special washer 3- washer 8 6- gasket...
  • Page 15 8.4.3 Fuel intake from return fuel pipe with T-connector Allowed fuel intake from the return fuel pipe (unloading fuel from the engine to the tank) with T-connector. Return fuel pipe should be free of pressure and goes at the bottom of the fuel tank.
  • Page 16: Post-Installation Testing

    8.5 Installation of heater electric circuit Heater wire harnesses shall be installed in compliance with the heater wiring system as shown in figure 4.1. When installing, do not allow the wire harnesses to become overheated, deformed or dislodged during vehicle use. Attach the harnesses to the vehicle fittings using plastic clamps.
  • Page 17: Recommendations

    ATTENTION! 1. When performing initial ignition following installation, the fuel supply line should be filled with fuel using a fuel pumping device until the fuel level reaches the inlet plug of the heater. If there is no pumping device, restart the heater as many times as necessary to fill the fuel supply line.
  • Page 18: Possible Malfunctions During Operations And Remedial Procedure For Heater Ignition Problems

    To fix breakdowns, proceed to the following steps: 1) remove the fuel supply pump from the vehicle; using a wrench (F/A 17), fix the pump in place, unscrew the pipe stub and remove the filter (see figure 10). Do fix the pump in place using surfaces other than surface A when removing and installing the pipe stub;...
  • Page 19: Transportation & Storage

    12 Transportation & storage 12.1 The heaters are safe to transport and may be transported by any means of transport, including air and rail transport providing the packed products are protected from atmospheric precipitations and climatic factors as per requirements specified in section 5 of GOST 15150-69 and mechanical effects as per requirements specified in category C of GOST 23216-78.