I/O Control Feature Descriptions - Genie Nano-CL M2450 User Manual

Nano-cl series camera link cmos area scan camera
Table of Contents

Advertisement

I/O Control Feature Descriptions

The following table describes these features along with their view attribute and minimum camera
firmware version required. Additionally the Device Version column will indicate which parameter is
a member of the DALSA Features Naming Convention (indicated by DFNC), versus the GenICam
Standard Features Naming Convention (SFNC tag is not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie Nano capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
Display Name
Trigger Selector
Single Frame Trigger(Start)
MultiFrame Trigger(Start)
Trigger Mode
Off
On
Trigger Frames Count
Software Trigger
Trigger Source
CC1
Software
Timer1End Event
Counter1End Event
Trigger Input Line Activation
Rising Edge
Falling Edge
Any Edge
Level High
Genie Nano-CL Series™
for easy identification.
Feature & Values
TriggerSelector
FrameStart
FrameBurstStart
TriggerMode
triggerFrameCount
TriggerSoftware
TriggerSource
Software
Timer1End
Counter1End
TriggerActivation
RisingEdge
FallingEdge
AnyEdge
LevelHigh
Description
Selects which type of trigger to configure with the
various Trigger features.
Selects a trigger starting the capture of a single
frame. Frame size is determined by image format
feature "Height".
Selects a trigger to capture multiple frames. The
number of frames is specified by the
"triggerFrameCount" feature.
Controls the enable state of the selected trigger.
Off
The selected trigger is turned off.
On
The selected trigger is turned active.
Sets the total number of frames to acquire when a
valid trigger is received. This feature is available
when Trigger Selector = MultiFrame Trigger(Start).
Generate a software command internal trigger
immediately no matter what the TriggerSource
feature is set to.
Specifies the internal signal or physical input line to
use as the trigger source. The selected trigger
must have its TriggerMode set to ON.
CC1
Select CC1 (and associated I/O control block) to
use as the external trigger source. See
LineSelector feature for complete list.
The trigger command source is only generated by
software using the Trigger Software command.
Select the TimerEnd Event as the internal trigger
source.
Select the CounterEnd Event as the internal trigger
source.
Select the activation mode for the selected Input
Line trigger source. This is applicable only for
external line inputs.
The trigger is considered valid on the rising edge of
the line source signal (after any processing by the
line inverter module).
The trigger is considered valid on the falling edge
of the line source signal (after any processing by
the line inverter module).
The trigger is considered valid on any edge of the
line source signal (after any processing by the line
inverter module).
The trigger is considered valid on the high level of
the line source signal.
Operational Reference
Device
Version
& View
1.00
Beginner
1.00
Beginner
1.00
DFNC
Beginner
1.00
Beginner
1.00
Beginner
1.00
Beginner
45

Advertisement

Table of Contents
loading