RS-232 Connection
Connect to RS-232 using the RJ45 jack on the front Base module, using the supplied
RJ45 male to serial (DB9 female) cable. Note: RTS is reserved for use by the
configuration software only. Asserting RTS during normal operation will result in a
communication failure. Disable RTS if your hardware supports it.

Power Supply Requirements

Zlinx 485 systems can be powered from 10 to 30 VDC power sources. No supply is
included since the power rating of the supply will depend on the total power requirements
of all modules used in the system.

Mounting Hardware

Zlinx 485 modules can be DIN rail mounted. The DIN mounting clip and spring is
included on each module.
Figure 10.
No jumpers are required to bridge the transmit and receive lines in two-wire mode.
Note: A standard RJ45 to serial (DB9) cable will not work, use only the one supplied
Appendix A contains a listing of power requirements for all Zlinx 485 modules.
RS-485 Two-Wire Connection
Manual Documentation Number: Zlinx485m-1808
Hardware
www.bb-elec.com