Instruction Manual Control and Switch Panel LT 500
Tank level switch
5.12.1
5.12.2
5.12.3
5.12.4
10
5.11
Switching the waste water tank heater on and off
The waste water tank heater still works when the control and switch panel is
switched off. To switch the waste water tank heater on and off, the control and
switch panel must be switched on.
Press the right side of the tank level switch for more than 3 seconds:
The waste water tank heater is switched on. The yellow indicator lamp
lights up.
Press the right side of the tank level switch again for more than 3 seconds:
The waste water tank heater is switched off. The yellow indicator lamp
does not light up.
5.12
Additional messages
Charge request "CHARGE !"
The red "CHARGE !" warning lamp flashes as soon as the battery voltage is
insufficient. The system shuts down after approx. 5 minutes. This alarm mes-
sage still appears, even if the control and switch panel is switched off. The
batteries must now be recharged.
For more information see section 5.5 as well as the instruction manual of the
Electrobloc.
The control and switch panel can only be switched on, if the living area battery
voltage is above 11.0 V. If the voltage is insufficient, the 12 V indicator lamp
and the "V" symbol flash if an attempt is made to switch on the control and
switch panel.
Battery capacity alarm
If the residual capacity of the living area battery voltage is insufficient (below
approx. 15%), the red "CHARGE !" warning lamp lights up. Charge the bat-
teries. The battery capacity alarm is not active when the 12 V main switch is
switched off.
Battery capacity unclear
If the battery capacity is checked and the system is not able to determine a
clear value, the red "CHARGE !" warning lamp and the red "?" warning lamp
flash. This can for example happen after starting up the system or after
changing batteries.
Fully charge the battery using the 230 V power supply, a defined charge sta-
tus is then restored. When the charging process is completed, both warning
lamps go out.
Mains alarm
The yellow 230 V indicator lamp flashes when the vehicle's engine is started
and if at the same time the input of the Electrobloc is live.