Appendix B: Technical Specifications; Environmental Specifications; Dc Power Requirements; Current Requirements - Intel RES3FV288 Hardware User's Manual

Raid expander card
Table of Contents

Advertisement

Appendix B:

Environmental Specifications

Note: Your RAID Expander requires adequate airflow to operate reliably. The recommended airflow is 200 LFM
(linear feet per minute), minimum to avoid operating above the maximum ambient temperature. Forced airflow is
required.
The thermal and atmospheric characteristics are:
Ambient temperature with forced airflow
Relative humidity
Altitude
The storage and transit environment conditions are:
Ambient temperature with forced airflow
Relative humidity
Mean Operating Time Between Failures number (MTBF):
electrical components
Note: Ambient temperature is measured 1" from the expander processor.

DC Power Requirements

Current Requirements

RAID Expander RES3FV288
17
Intel® RAID Expander Card RES3FV288 Hardware User's Guide
Technical Specifications
Bus Type
Description
PCIe
Ripple and noise
Product
0°C to 55°C
20% to 80%, non-condensing
Up to 3,000 meters
-30°C to 80°C (dry bulb)
5% to 90%, non-condensing
TBD hours at 40°C
RAID Expander
12V: TBD mV peak-to-peak (max)
Typical Current
All power is supplied to the RES3FV288 French Valley
RAID Expander Card through the standard PCI Express
connector's 12 V rails, or a remote RA 4-pin 12V power
connector. The +12 V rail is used to generate the other
required voltage rails of 3.3V, 1.8V, 1.005V, and 0.925V
and +1.8 V.
The max operation power is TBD W.
Requirements

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents