Mitsubishi Electric GT1020-LBD General Description

Mitsubishi Electric GT1020-LBD General Description

Gt10/got1000 series

Advertisement

Quick Links

JY997D22901R
Side
JAPANESE
A
Side
ENGLISH
B
GT1020-LD(W)/LD(W)2/LL(W)
GT10 General Description
Manual Number
JY997D22901R
Date
Oct. 2016
This manual describes the specifications of the product. Before use, read this
manual and manuals of relevant products fully to acquire proficiency in handling
and operating the product. Make sure to learn all the product information, safety
information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective Oct. 2016
Specifications are subject to change without notice.
2008 MITSUBISHI ELECTRIC CORPORATION
Safety Precaution
(Read these precautions before using.)
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by "CAUTION" may also be
linked to serious results.
In any case, it is important to follow the directions for usage.
DESIGN PRECAUTIONS
 Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
 If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
 Do not use the GOT as the warning device that may cause a serious
accident. An independent and redundant hardware or mechanical interlock is
required to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
 Incorrect operation of the touch switch(s) may lead to a serious accident if the
GOT backlight is gone out. When the GOT backlight goes out, causes the
monitor screen to appear blank, while the input of the touch switch(s) remains
active. This may confuse an operator in thinking that the GOT is in
"screensaver" mode, who then tries to release the GOT from this mode by
touching the display section, which may cause a touch switch to operate.
DESIGN PRECAUTIONS
 Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.
 Do not press the GOT display section with a pointed material as a pen or
driver. Doing so can result in a damage or failure of the display section.
 Before connecting to GOT, turn ON the controller to enable the
communication. When the communication of controller is not available, a
communication error may occur in GOT.
Side
B
MOUNTING PRECAUTIONS
 Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT to/from the panel.
Not doing so can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
 Use the GOT in the environment that satisfies the general specifications
described in this manual. Not doing so can cause an electric shock, fire,
malfunction or product damage or deterioration.
 When mounting the GOT to the control panel, tighten the mounting screws in the
specified torque range. Undertightening can cause the GOT to drop, short circuit
or malfunction, and deteriorate the waterproof effect and oilproof effect.
Overtightening can cause a drop, short circuit or malfunction due to the damage
of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect
due to distortion of the protective cover for oil, GOT or panel.
 When using the GOT in the environment of oil or chemicals, use the protective
cover for oil. Failure to do so may cause failure or malfunction due to the oil or
chemical entering into the GOT.
WIRING PRECAUTIONS
 Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may result in an electric shock, product damage or
malfunctions.
 Please make sure to ground FG terminal of the GOT power supply section by
applying 100 or less which is used exclusively for the GOT. Not doing so may
cause an electric shock or malfunction.
 Correctly wire the GOT power supply section after confirming the rated voltage
and terminal arrangement of the product. Not doing so can cause a fire or failure.
 Tighten the terminal screws of the GOT power supply section in the specified
torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the
screws or the GOT.
 Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT. Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
 Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction. Overtightening can
cause a short circuit or malfunction due to the damage of the screws or unit.
TEST OPERATION
PRECAUTIONS
 Before performing the test operations of the user creation monitor screen (such as
turning ON or OFF bit device, changing the word device current value, changing
the settings or current values of the timer or counter), read through the manual
carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system. False output or malfunction can
cause an accident.
STARTUP/MAINTENANCE
PRECAUTIONS
 When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
 Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can cause
a unit failure or malfunction. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction due to the
damage of the screws or unit.
STARTUP/MAINTENANCE
PRECAUTIONS
 Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
 Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
 The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
 When unplugging the cable connected to the unit, do not hold and pull the cable
portion. Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
 Before touching the unit, always touch grounded metal, etc. to discharge static
electricity from human body, etc.
Not doing so can cause the unit to fail malfunction.
DISPOSAL PRECAUTIONS
 When disposing of the product, handle it as industrial waste.
TOUCH PANEL
PRECAUTIONS
 For the analog-resistive film type touch panels, normally the adjustment is not
required. However, the difference between a touched position and the object
position may occur as the period of use elapses. When any difference between
a touched position and the object position occurs, execute the touch panel
calibration.
 When any difference between a touched position and the object position occurs,
other object may be activated. This may cause an unexpected operation due to
incorrect output or malfunction.
TRANSPORTATION
PRECAUTIONS
 Make sure to transport the GOT main unit and/or relevant unit(s) in the manner
they will not be exposed to the impact exceeding the impact resistance
described in the general specifications of this manual, as they are precision
devices. Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive for the entire mechanical module should be checked by
the user / manufacturer. For more details please contact the local Mitsubishi Electric
sales site.
Attention
 This product is designed for use in industrial applications.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (to the
identified standards) and design analysis (forming a technical construction file) to the
European Directive for Electromagnetic Compatibility (2004/108/EC) when used as
directed by the appropriate documentation.
Type :Programmable Controller (Open Type Equipment)
Standard
Remark
Compliance with all relevant aspects of the
EMI
standard. (Radiated Emissions)
EN61131-2 : 2007
Programmable
Compliance with all relevant aspects of the
controllers-
standard.
Equipment,
EMS
(ESD,RF electromagnetic field, EFTB, Surge, RF
requirement and tests
conducted disturbances and Power frequency
magnetic field)
For more details please contact the local Mitsubishi Electric sales site.
Notes for compliance to EMC regulation
1) General notes on the use of communication cables
Any device which utilizes a data communication function is susceptible to the
wider effects of local EMC noise. Therefore, when installing any communication
cables care should always be taken with the routing and location of those cables.
The GOT units identified on the previous chapter are compliant with the EMC
requirement when the following communication cables are used.
GOT Unit
Existing Cables
G T 1 0 2 0 - L B D / LW D , G T 1 0 2 0 - L B L / LW L ,
GT10-C30R4-8P (For Melsec
GT1020-LBDW/LWDW, GT1020-LBLW/LWLW
FX series PLC)
GT1020-LBD2/LWD2, GT1020-LBDW2/
GT10-C30R2-6P (For Melsec
LWDW2
Q series PLC)
2) General notes on the use of the power cable
The GT1020-LBD/LWD/LBD2/LWD2/LBDW/LWDW/LBDW2/LWDW2 unit
demand that the cable for the power supply is 10m or less.
Associated Manuals
Manual Number
Manual name
Contents
(Model Code)
Describes the GT10 hardware-relevant
G T 1 0 U s e r ' s
c o n t e n t s u c h a s pa r t n a m e s , e x t e r n a l
Manual
JY997D24701
dimensions, mounting, power supply wiring,
( s o l d
specifications, and introduction to option
separately)
devices
Manual name
Contents
G O T 1 0 0 0
S e r i e s
Describes system configurations
Connection Manual 1/3,
o f t h e c o n n e c t i o n m e t h o d
2/3, 3/3
applicable to GOT1000 series and
(sold separately)
*1
cable creation method
GT Designer2 Version2
Describes methods of the GT
Basic Operation/Data
Designer2 installation operation,
Transfer Manual (For
basic operation for drawing and
GOT1000 Series)
transmitting data to GOT1000
(sold separately)
*1
series
GT Designer2 Version2
Screen Design Manual
D es c ri be s sp e ci f ic a ti on s an d
(For GOT1000 Series) 1/
settings of the object functions
3, 2/3, 3/3
used in GT Designer2
(sold separately)
*1
GT Designer3
Version1 Screen
Describes methods of the GT
Design Manual
Designer3 installation operation,
(For GOT1000 Series)
basic operation for drawing and
(Fundamentals)
transmitting data to GOT1000
1/2, 2/2
series
(sold separately)
*1
GT Designer3
Version1 Screen Design
Manual
D es c ri be s sp e ci f ic a ti on s an d
(For GOT1000
settings of the object functions
Series)
used in GT Designer3
(Functions) 1/2, 2/2
(sold separately)
*1
*1 Stored in the GT Works2/GT Designer2/GT Works3/GT Designer3 in PDF format.
For details of a PLC to be connected, refer to the PLC user's manual respectively.
Bundled Items
Model Name
GT1020-LBD/LWD
GT1020-LBD2/LWD2
GOT main unit
GT1020-LBL/LWL
(The maintenance supplies below are packed with the
GT1020-LBDW/LWDW
product.)
GT1020-LBDW2/LWDW2
GT1020-LBLW/LWLW
Maintenance Supplies
PLC Communication Connector
Panel Mounting Bracket (with M4  20 screws)
Panel Mounting Packing
GT10 General Description (This manual)
「电器电子产品有害物质限制使用标识要求」 的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称, 含有量, 含有部品
 本产品中所含有的有害 6 物质的名称, 含有量, 含有部品如下表所
示。
产品中有害物质的名称及含量
有害物质
部件名称
(Pb)
(Hg)
(Cd)
(Cr(VI))
显 示 器
外壳
GOT
印刷基板
×
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
(09R819)
规定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
Manual Number
(Model Code)
SH-080532ENG
(1D7M26)
SH-080529ENG
(1D7M24)
SH-080530ENG
SH-080531ENG
(1D7M25)
SH-080866ENG
(1D7MB9)
SH-080867ENG
(1D7MC1)
Remark
Quantity
1
4
1
1
多溴
六价铬
多溴联苯
二苯醚
(PBB)
(PBDE)

Advertisement

loading

Summary of Contents for Mitsubishi Electric GT1020-LBD

  • Page 1 (Functions) 1/2, 2/2  cause an electric shock or malfunction. the user / manufacturer. For more details please contact the local Mitsubishi Electric 2008 MITSUBISHI ELECTRIC CORPORATION (sold separately)  Correctly wire the GOT power supply section after confirming the rated voltage sales site.
  • Page 2 300 [cd/m ] (in white) voltage drop, while it automatically resumes operation as soon as the power is kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation restored. cannot be held responsible for any problems involving industrial property rights Life Approx.
  • Page 3  2008 MITSUBISHI ELECTRIC CORPORATION the user / manufacturer. For more details please contact the local Mitsubishi Electric (sold separately)  Correctly wire the GOT power supply section after confirming the rated voltage sales site.

This manual is also suitable for:

Gt1020-lwdGt1020-lbd2Gt1020-lblGt1020-lwd2Gt1020-lbdwGt1020-lwl ... Show all