Download Print this page

Mitsubishi Electric MELSEC iQ-F FX5 Hardware Manual page 2

Simple motion module
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

1.3 Power and Status LED
: OFF, : ON, : Flashing
(Flashing interval ON: 200 ms/OFF: 200 ms)
LED display
Description
FX5-40SSC-S:
AX1, AX2, AX3, AX4
Power of Simple
POWER LED is OFF
FX5-80SSC-S: AX1-8
Motion module is OFF
POWER, RUN, ERROR
FX5-40SSC-S:
RUN LED is ON
*1
AX1, AX2, AX3, AX4
The axes stopped
ERROR LED is OFF
*2
FX5-80SSC-S: AX1-8
The axes on standby
AX LED is OFF
POWER, RUN, ERROR
FX5-40SSC-S:
*3
AX1, AX2, AX3, AX4
AX LED is ON
The axis in operation
*4
FX5-80SSC-S: AX1-8
POWER, RUN, ERROR
FX5-40SSC-S:
*5
AX1, AX2, AX3, AX
ERROR LED is ON
Minor error
*6
FX5-80SSC-S: AX1-8
AX LED is Flashing
POWER, RUN, ERROR
FX5-40SSC-S:
AX1, AX2, AX3, AX4
ERROR LED is
Moderate error
FX5-80SSC-S: AX1-8
Flashing
Watchdog timer error
POWER, RUN, ERROR
*1 The stop or standby AX LED is OFF.
*2 When all axes are stopped or on standby, the AX LED turns OFF.
*3 The operating AX LED is ON.
*4 When any of the axes is in operation, the AX LED turns ON.
*5 The AX LED in which error occurred is flashing.
*6 When an error occurs in any of the axes, the AX LED is flashing.
1.4 Signal Layout for External Input Connection Connector
For further information on the input wiring and input cable, refer to the following
manual.
MELSEC iQ-F FX5 Simple Motion Module User's Manual (Startup)
26
13
12
25
11
24
23
10
9
22
8
21
7
20
6
19
18
5
4
17
3
16
15
2
1
14
Front view
of the module
Pin No.
Signal name
Pin No.
Signal name
1
No connect
14
No connect
2
SG
15
SG
Signal ground
Signal ground
Manual pulse
Manual pulse
g e n e r a t o r /
g e n e r a t o r /
Incremental
Incremental
3
HA
16
HB
s y n c h r o n o u s
s y n c h r o n o u s
encoder
encoder
*1
A-phase/PULSE
B-phase/SIGN
Manual pulse
Manual pulse
4
HAH
17
HBH
g e n e r a t o r /
g e n e r a t o r /
Incremental
Incremental
s y n c h r o n o u s
s y n c h r o n o u s
encoder
encoder
5
HAL
18
HBL
*2
A-phase/PULSE
B-phase/SIGN
6 to 9
No connect
19 to 22
No connect
Forced stop input
E M I .
Forced stop input
10
EMI
23
signal
COM
signal common
11
DI1
24
DI2
E x t e r n a l
External command/
command/
Switching signal
12
DI3
25
DI4
Switching signal
13
COM
Common (COM)
26
COM
Common (COM)
*1 Voltage-output/open-collector type
*2 Differential-output type
1.5 Power supply connector
For further information on the power supply wiring and power cable, refer to the
following manual.
MELSEC iQ-F FX5 Simple Motion Module User's Manual (Startup)
3 Grounding
(Green)
2
(Black)
1
(Red)
2. Installation
INSTALLATION
PRECAUTIONS
 Completely turn off the externally supplied power used in the system before
installing or removing the module. Not doing so could result in electric shocks, an
operation failure or damage to the module.
INSTALLATION
PRECAUTIONS
 Never try to disassemble or modify the modules. It may cause product failure,
operation failure, injury or fire.
 Use the programmable controller in an environment that meets the general
specifications in the manual supplied with the CPU module. Using the
programmable controller in an environment outside the range could result in
electric shock, fire, operation failure, and damage to or deterioration of the
product.
 Do not directly touch the module's conductive parts and electronic components.
Doing so may could cause an operation failure or give damage to the module.
 Lock the control panel and prevent access to those who are not certified to handle
or install electric equipment.
2.1 Arrangements
The product connects on the right side of CPU module or extension module.
For further information of installation arrangements, refer to the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
2.2 Mounting
The product is mounted by the following method.
 Direct mounting (Mounting screw: M4 screw)
 DIN rail mounting
For further information on mounting, refer to the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
3. Specification
DISPOSAL
PRECAUTIONS
 Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
 The product is a precision instrument. During transportation, avoid any impacts.
Failure to do so may cause failures in the product.
3.1 Applicable PLC
*1
Model name
Applicability
FX5-40SSC-S: Ver. 1.000 or later (from first
FX5U PLC
production)
FX5-80SSC-S: Ver. 1.014 or later
FX5-40SSC-S: Ver. 1.000 or later (from first
FX5UC PLC
production)
*2
FX5-80SSC-S: Ver. 1.014 or later
3.2 General Specifications
The items other than the following are equivalent to those of the CPU module.
For the general specification, refer to the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
Items
Specifications
O p e r a t i n g
a m b i e n t
0 to 55 °C
temperature
D i e l e c t r i c
w i t h s t a n d
500 V AC for 1 minute
B e tw e e n al l t e r m i n a l s a n d
voltage
ground terminal
I n s u l a t i o n
10 M or higher by 500 V DC
resistance
insulation resistance tester
3.3 Power Supply Specifications
Items
Power supply voltage
24 V DC +20% -15%
Permitted
O p e r a t i o n c o n t i n u e s w h e n t h e
instantaneous
instantaneous power failure is shorter
Ex ternal power
power failure time
than 5 ms.
supply
Power consumption
6 W
Power fuse
1 A
I n t e r n a l p o w e r
PLC power supply
Not used.
supply
3.4 Performance Specifications
Items
Number of control axes
Operation cycle
External wiring connection system
Applicable wire size
External input wiring connector
*2
MR-J3BUS_M
SSCNETIII
*2
MR-J3BUS_M-A
cable
*2*3
MR-J3BUS_M-B
Flash memory (Flash ROM)
write count
No. of occupied I/O points
2
*1 AWG24 (0.2 mm
) is recommended.
*2 _ = Cable length (015: 0.15 m (0.49 ft.), 03: 0.3 m (0.98 ft.), 05: 0.5 m (1.64
ft.), 1: 1 m (3.28 ft.), 3: 3 m (9.84 ft.), 5: 5 m (16.40 ft.), 10: 10 m (32.81 ft.),
20: 20 m (65.62 ft.), 30: 30 m (98.43 ft.), 40: 40 m (131.23 ft.), 50: 50 m
(164.04 ft.) )
*3 For the cable of less than 30 m (98.43 ft.), contact your nearest Mitsubishi
sales representative.
Specifications
This manual confers no industrial property rights or any rights of any other
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Specifications
FX5-40SSC-S: 4 axes
FX5-80SSC-S: 8 axes
0.888 ms/1.777 ms
26-pin connector
2
*1
AWG30 to 24 (0.05 to 0.2 mm
)
LD77MHIOCON
 FX5SSC
 M R - J 4 ( W ) - B / M R - J E - B ( F ) / M R -
J3(W)-B
 MR-J4(W)-B/MR-JE-B(F)/MR-J3(W)-B
 M R - J 4 ( W ) - B / M R - J E - B ( F ) / M R -
J3(W)-B
 Standard cord for inside panel
0.15 m (0.49 ft.), 0.3 m (0.98 ft.), 0.5 m
(1.64 ft.), 1 m (3.28 ft.), 3 m (9.84 ft.)
 FX5SSC
 M R - J 4 ( W ) - B / M R - J E - B ( F ) / M R -
J3(W)-B
 MR-J4(W)-B/MR-JE-B(F)/MR-J3(W)-B
 M R - J 4 ( W ) - B / M R - J E - B ( F ) / M R -
J3(W)-B
 Standard cable for outside panel
5 m (16.40 ft.), 10 m (32.81 ft.), 20 m
(65.62 ft.)
 FX5SSC
 M R - J 4 ( W ) - B / M R - J E - B ( F ) / M R -
J3(W)-B
 MR-J4(W)-B/MR-JE-B(F)/MR-J3(W)-B
 M R - J 4 ( W ) - B / M R - J E - B ( F ) / M R -
J3(W)-B
 Long distance cable
30 m (98.43 ft.), 40 m (131.23 ft.), 50 m
(164.04 ft.)
Max. 100000 times
8 points
FX5SSC-U-HW

Advertisement

loading