FreshWell3000
Problem
Cause
Water enters the
The condensation water drainage open-
vehicle
ings are clogged up.
The seals are damaged.
No supply voltage (230 Vw) connected. ➤ Check the power supply.
Under-bench air
conditioner does
The voltage is too low (under 200 Vw).
not switch on.
The voltage converter is defective.
The defective thermal protection is
defective.
The electrical fuse of the power supply is
too low.
Under-bench air
The air filter is obstructed.
conditioner stops
The voltage is too low (under 200 Vw).
working.
The voltage converter is defective.
The defective thermal protection is
defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
One of the temperature sensors is
conditioner does
defective.
not switch off.
9

Disposal

Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and control the
influence that their activities (manufacturing, products, services, etc.) have on the
environment.
The procedures to be followed to identify significant environmental impact must take
the following factors into account:
• use of raw materials and natural resources
• atmospheric emissions
• discharge of liquids
EN
Remedy
➤ Clean the drainage openings for
condensation water.
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
➤ Check the electrical fuse of the
power supply.
➤ Clean the air filter.
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
Disposal