4-696-255-11(1)

Network Camera

Installation Manual
Before operating the unit, please read this manual thoroughly and
retain it for future reference.
SNC-VM642R/EM642R
© 2017 Sony Corporation
A
B
C
D
b
Cable holder
LAN cable holder
(supplied)
c-1
Guides
Guides
E
85.7 (3
3
/
)
8
46 (1
/
)
13
16
F
1
Wrench
Screw (4 positions)
2
Ceiling
3, 4
About the Manuals
Safety Regulations (included)
The Safety Regulations describes notes for the secure usage of camera. Be sure
to read it.
Installation Manual (this document)
Describes the names and functions of parts and controls of the Network Camera,
gives connection examples and explains how to set up the camera. Be sure to
read the Installation Manual before operating.
The illustration of SNC-VM642R is used for example purpose.
An I/O cable or power input cable is not supplied for SNC-EM642R.
Electronic Instruction Manual (Web)
ˎ
How to control the camera via a web browser
ˎ
How to setup the camera
Operate the camera referring to the guide above after having installed and
connected the camera properly based on the Installation Manual.
Assigning the IP address
1
Download the installer for "SNC toolbox" to a folder from the download
site.
2
Install the SNC toolbox.
Unzip the ZIP file of the downloaded installer.
Double-click "SncToolbox_Setup.exe. " For details on installing and use refer to
the Application Guide.
3
Assign an IP address.
Assign an IP address using the installed SNC toolbox. For details, see "Using
SNC toolbox" – "Assign an IP address" in the Application Guide.
Tip
SNC toolbox stands for Sony Network Camera toolbox.
Location and Function of Part
LAN port
The figure shows the camera without the dome casing.
Side
 Audio cable
The connector with the longer cable (SP) is used for the line output connector,
and the shorter cable (MIC) is used for the microphone/line input connector.
ˎ
SP terminal (minijack, monaural)
Connect a commercially available speaker system with a built-in amplifier.
ˎ
MIC terminal (minijack, monaural)
Connect a commercially available microphone. This jack supports plugin-
power microphones (rated voltage: 2.5 V DC).
 I/O (Input/Output) cable (SNC-VM642R only)
c-2
This cable is provided with two sensor inputs and two alarm outputs.
The wires of the cable control the following signals.
Color of wire
Red
White
Black
Yellow
Brown
Green
Blue
For details on each function and required settings, see the User's Guide.
For wiring, see "Connecting the I/O Cable" (P2).
 Wiring slit
Feed the wire rope through this.
For details, see "Installing the Camera."
 Base (PAN)
 Camera block
 Lens
 LAN cable (RJ-45)
Connect a commercially available network cable (UTP, category 5) to
communicate with a network or PoE/PoE+* system.
For details on connection, see the Instruction Manual of the power supply equipment.
Hole for
(*PoE/PoE+ stands for Power over Ethernet. It is pursuant to IEEE802.3at.)
connecting
cables
 Power input cable (SNC-VM642R only)
ø73 (2
7
/
)
8
Connect this cable to a 24 V AC or 12 V DC power supply system.
Horizontal
You can screw an extension cable in the connector tip attached at the end of the
marker
cable. Connect GND to the FG terminal (center of 3-pin connector). See
Hole for
illustration .
installing
 BNC cable
the bracket
Outputs a composite video signal.
 Side conduit hole (
3
/
inches NPT or M27 (2.0 mm (
4
hole diameter ø27 mm (
Vertical marker
Connect a pipe to this hole. There is a conduit hole on the side of the camera
unit. The conduit hole cover is installed in the side conduit hole at the factory.
Unit: mm (inches)
Remove the cover as needed and connect the pipe to the hole.
An M25 cable gland can be connected to the hole by removing the nut inside
the camera unit.
Note
Take care not to trap the cables between the camera and the ceiling or the wall. If
the cable is trapped, it may cause a fire or electric shock due to breaking.
 Camera head
Inside
The cables below are connected when the unit comes from the factory.
SNC-VM642R: , , , , 
SNC-EM642R: , , 
 Camera unit
 ZOOM/FOCUS switch
Use this switch to adjust lens' zoom and focus. Slide the switch lever to select the
desired function.
[W] WIDE: Zoom out
[T] TELE: Zoom in
[N] NEAR: Focus on a nearby subject
[F] FAR: Focus on a distant subject
Hold down the center of the ZOOM/FOCUS switch for a moment to focus automatically.
 Camera unit mounting screws (four positions)
Make sure to tighten the screws securely when installing the camera.
 AC / DC IN (power input) connector (SNC-VM642R only)
Connect the power input cable.
 MONITOR output jack
Connect this jack to a video input connector of a video monitor. You can adjust
the camera or lens while looking at the image on the video monitor. After
adjusting the camera or lens, disconnect the cable.
Bracket (supplied)
 Camera block fixing screws (tilt) (two positions)
Firstly, loosen the screws and point the camera block in the desired direction,
then tighten the screws to secure in place.
 Nut (
/
inches NPT or M27 (2.0 mm (
3
Commercially-available
4
screw (4)
 Safety cord
This cord prevents the dome casing from falling off the unit.
  TOP mark
Indicates the image direction.
Locating pin
 LAN network port (RJ-45)
Connect the LAN cable (RJ-45).
 Dome casing
Groove
The dome cover is made of polycarbonate. A waterproof rubber gasket is
provided on the joint surface to the unit.
 SD card slot
Wire rope
This slot is used for optional SD memory cards.
(supplied)
Image data in the camera can be recorded to a memory card by inserting it into
the slot.
Gently insert an SD card in (see illustration) until it clicks into place.
This unit is only compatible with SD and SDHC memory cards.
Note
ScrewM4×8
For inquiries regarding verified SD memory cards, contact your authorized Sony
(supplied)
dealer.
 POWER indicator (Green)
Holder
When the power is supplied to the camera, the camera starts checking the
system. If the system is normal, this indicator lights up.
 HEATER indicator (Green)
The indicator lights up in green when the built-in heater is working normally.
Camera unit mounting
 NETWORK indicator (Green/Orange)
screw (supplied) (4)
The indicator lights up or flashes when the camera is connected to the network.
The indicator is off when the camera is not connected to the network.
 Reset switch
To reset the camera to the factory default settings, hold down this switch with a
point and supply the power to the camera.
 Mode setting DIP switches
DIP switch function/settings
SNC-VM642R
Switch No.
Up (ON)
Down (OFF)
1 VIDEO (NTSC/PAL) switch (Initial setting: NTSC)
Switches the video output.
After setting the switch, reboot the camera unit.
2 POWER (PoE+, AC, DC/PoE) switch (Initial setting: PoE+, AC, DC)
Switch PoE+, AC, DC/PoE, depending on the power source you are using.
Note
When power is supplied by IEEE802.3af (PoE) equipment, if the switch is set to
PoE+, the camera will not work properly.
When the power is supplied via power supply equipment that complies with
IEEE802.3at (PoE+), an AC power adaptor, or a DC power adaptor, the heater will
not work if the switch is set to PoE. Please note that the camera may not work in
a cold environment.
SNC-EM642R
Switch No.
Up (ON)
Down (OFF)
1 VIDEO (NTSC/PAL) switch (Initial setting: NTSC)
Switches the video output.
After setting the switch, reboot the camera unit.
2 PoE PWR switch (Initial setting: PoE)
Switch between PoE+/PoE based on your PoE hub.
Note
When power is supplied by IEEE802.3at (PoE+) equipment, if the switch is set to
PoE, the range of activation and operating temperature is limited.
When power is supplied by IEEE802.3af (PoE) equipment, if the switch is set to
PoE+, the camera will not work properly.
 EXT CTRL (external control input/output) connector (SNC-VM642R
only)
Connect the I/O (Input/Output) cable.
 AUDIO connector
Connect the audio cable.
 VIDEO OUT (video output) connector
Connect the BNC cable.
Bottom
 Cable holder
Packing for waterproofing the cables.
Name
 Holder plate
Sensor In 1+
Fixes the cable holder.
Sensor In 2+
Sensor In – (GND)
 GND
Alarm Out 1+
Ground the camera when you install it.
Alarm Out 1–
Note
Alarm Out 2+
Use the supplied Screws  (M4 × 8)
Alarm Out 2–
 Holder plate fixing screws (three positions)
Fixes the holder plate.
 Rating label
Shows the name of this camera and its electric rating.
Preparations
Change connections and cable wiring
To change connections and cable wiring to suit your requirements, perform the
following steps.
When you route the cables from the side of the camera unit, see "Connecting to the
side conduit hole".
a) If you use the camera with its factory setting
The preparation is completed.
b) If you use the LAN cable only
1
Loosen the four screws of the dome casing using the supplied wrench and
remove the dome casing.
2
Loosen the three holder plate fixing screws on the bottom to remove the
holder plate and cable holder.
3
Disconnect all the cables from the connectors and remove them from the
cable holder.
4
Insert the LAN cable through the hole of the LAN cable holder (replace the
3
/
inches)-pitched,
32
cable holder with the LAN cable holder).
inches)))
1
1
/
8
5
Insert the LAN cable through the bottom hole and adjust the length of the
LAN cable from the hole to the LAN port.
6
Connect the LAN cable to the LAN port.
7
Attach the removed holder plate to the bottom hole with the three holder
plate fixing screws.
c) For other cases
1
Loosen the four screws of the dome casing using the supplied wrench and
remove the dome casing.
2
Loosen the three holder plate fixing screws to remove the holder plate and
cable holder.
3
Remove all the cables from the cable holder and disconnect unnecessary
cables from the connectors.
Notes
For case b), if you use your own LAN cable, keep its diameter
ˎ
inches) - ø6.0 mm (
For case c), if you need to waterproof the camera, see "Important precautions"
ˎ
(P2).
Do not pull on any cables forcefully, as a connection may become loose.
ˎ
If the cables are removed from the guides, pass the cables through the guides
ˎ
and secure them again.
For case c), do not attach the cable plate and cable holder.
ˎ
d) Connecting to the side conduit hole
All the cables are connected to the camera through the bottom hole at the
factory. If you want to use the side conduit hole, perform the following steps:
1
Remove the conduit hole cover.
2
Loosen the three holder plate fixing screws on the bottom to remove the
holder plate and cable holder.
3
Disconnect all the cables from the connectors, and pull them out through the
bottom hole.
4
Insert the necessary cables through the pipe, then through the supplied
cable holder (for conduit), and finally through the side conduit hole. (-c-2)
5
Connect the cables to the connectors.
6
Secure the cables through the guides. (-c-1)
7
Screw the removed conduit hole cover into the bottom hole.
Notes
/
inches)-pitched))
3
32
ˎ
If the bottom hole is dirty, the conduit hole cover cannot be fixed firmly. In this
case, moisture may leak into the casing and this may cause a malfunction.
Wipe off the dust with a soft cloth, and fix the conduit hole cover firmly.
ˎ
Cover the joint part of the pipe/cover with silicon sealant, etc. to prevent
moisture from getting inside the casing.
ˎ
The holder plate and the cable holder are not necessary when you attach the
conduit hole cover to the bottom hole.
ˎ
Be careful not to drop the conduit hole cover and nut (
removing the camera.
ˎ
For details on using the supplied cable holder (for Conduit), see "Important
precautions" (P2).
Installation
WARNING
If you attach the camera in the height such as the wall or the ceiling, etc.,
ˎ
entrust the installation to an experienced contractor or installer.
ˎ
If you install the camera at a height, ensure that the installation location and
its material are strong enough to withstand a weight of 15 kg (33 lb 11 oz) or
more, and then install the camera securely. If the ceiling is not strong enough,
the camera may fall and cause serious injury.
ˎ
To prevent the camera from falling, make sure to attach the supplied wire rope.
ˎ
If you attach the camera to the ceiling, check periodically, at least once a year,
to ensure that the connection has not loosened. If conditions warrant, make
this periodic check more frequently.
Deciding the Installation Location of the Camera 
After deciding the direction in which the camera will shoot, make the required
hole (ø73 mm (2
template. Then decide the four mounting hole positions to install the bracket.
Mounting screws
The supplied bracket is provided with eight ø4.5 mm (
holes. Install the bracket on a ceiling or wall with screws through four mounting
holes: two 83.5 mm (3
pitched holes. The required mounting screws differ depending on the installation
location and its material. Use commercially-available screws.
Steel wall or ceiling: Use M4 bolts and nuts.
1
2
Wooden wall or ceiling: Use M4 tapping screws. The panel thickness must be
15 mm (
VIDEO
POWER
Concrete wall: Use anchors, bolts and plugs suitable for concrete walls.
PAL
PoE+, AC, DC
Junction box: Use screws to match the holes on the junction box.
NTSC
PoE
WARNING
The required mounting screws differ depending on the installation location and
its material. If you do not secure the camera with the appropriate mounting
screws, the camera may fall off.
Installing the Camera
1
Remove the dome casing.
 Loosen the screws with the wrench (supplied).
 Pull up and remove the dome casing. When the screw catches on the
screw hole, pull up the screw.
2
Install the supplied bracket on the ceiling or wall.
Refer to "Mounting screws" for screws to be used.
3
Fix the supplied wire rope to the camera unit and the ceiling or wall.
 Fix the wire rope with the supplied Screw  M4
1
2
wire rope on the bottom of the camera unit.
 Fix the wire rope to the ceiling or wall.
VIDEO
PoE PWR
PoE+ (at) –40°C to +50°C
When you install the camera on a wall, feed the cables through one of the
PAL
(–40°F to +122°F)
wiring slits. (-3)
4
PoE (af ) –30°C to +50°C
Attach the camera unit to the bracket with the supplied four camera unit
NTSC
(–22°F to +122°F)
mounting screws.
The screws have a fall-prevention mechanism. The screws inserted into the
screw holes of the camera unit do not fall even if you turn the camera unit
upside down.
Insert the two holders to any two of the four grooves on the bracket.
Turn the camera clockwise until the locating pins snap to the holes on the
holders. Then the four camera installation holes will align the projections on
the bracket accordingly. There are four projections with an angle of
90 degrees, so you can select one of four directions.
Then tighten the four camera unit mounting screws to attach the camera unit
to the bracket through the camera installation holes.
Note
If you cannot use screws on a ceiling or wall, or if you want to make the camera
less conspicuous, use the YT-ICB45 in-ceiling bracket (optional) with which you
can mount the camera on the ceiling.
For this model, install the camera to the  position on the side brackets of
YT-ICB45. Refer to the Installation Instructions of YT-ICB45 for detail information.
ø5.0 mm (
/
7
32
/
inches). Otherwise, waterproof the bottom hole.
1
4
-7) when installing or
7
/
inches)) for the connecting cables using the supplied
8
3
/
inches) mounting
16
9
/
inches)-pitched holes or four 85.7 mm (3
3
/
inches)-
32
8
5
/
inches) or more.
8
8 to the hole for the
×

Advertisement

loading

Summary of Contents for Sony SNC-VM642R

  • Page 1: Network Camera

    Make sure to tighten the screws securely when installing the camera. Loosen the three holder plate fixing screws on the bottom to remove the Ceiling  AC / DC IN (power input) connector (SNC-VM642R only) holder plate and cable holder. Connect the power input cable.
  • Page 2 –40°C to +50°C (–40°F to +122°F) (PoE+) –30°C to +50°C (–22°F to +122°F) (PoE) Connecting to 12 V DC or 24 V AC source (SNC-VM642R) You can adjust all tilt and rotation positions. There is no screw for rotation and Storage temperature –20°C to +60°C (–4°F to +140°F)

This manual is also suitable for:

Snc-em642r