Inis Oirr MK2 Multifuel Boiler stove Congratulations on the purchase of your new Inis Oirr MK2 Boiler stove. We here at Inis Stoves truly love building high quality stoves for our customers. The stove we produced for you was not just an appliance to us.
Your that they have ignited a small fire in Inis Oirr MK2 boiler stove has a manual the stove and it is operating correctly. ”Easy Start” damper fitted to the...
Inis Oirr MK2 Multifuel Boiler stove around the stove that will refuelling should only be needed every interfere with the proper heat 90 minutes (when burning wood) at full convection and air supply to the output and the stove will operate most stove.
The stove has two ash pans designed for Continuous burning ease of handling. The ash pans should be Your Inis Oirr MK2 boier stove is capable emptied before it is over filled to of continuous burning making overnight protect the grate from overheating burning possible at a reduced output.
Page 6
Inis Oirr MK2 Multifuel Boiler stove removed. Next the upper centre plate can the grate side plates are removed by be removed by pushing upwards at the moving the front end of the plate up. front of the plate and then lifting the...
Inis Oirr MK2 Multifuel Boiler stove excess heat loss through the stove up the Some/all radiators not heating chimney. After a prolonged period being Check that the fire is burning at unused, inspect the chimney before use to full output ensure no blockage has occurred.
Inis Oirr MK2 Multifuel Boiler stove Chimney fire If further help is needed please If the stove and chimney are kept contact the retailer of the clean, no fire should occur. If stove. We take pride in choosing however it does happen, close the...
Inis Oirr MK2 Multifuel Boiler stove Installation Manual Specification Output Water Flue Dia Flue Gas Temperature Fuel Wood, eco fuels, peat dried, smokeless coal Min distance to combustibles Rear Sides CO @ 13%O2 0.14 Stove Mass Max Hearth Temp Installation Instructions...
Inis Oirr MK2 Multifuel Boiler stove When deciding on where to place a vent, which will help to balance high and the installer must ensure that the low pressure zones due to wind position will not cause undue air conditions. The flexible aluminium...
Inis Oirr MK2 Multifuel Boiler stove unless adjacent fireproofing fitted. The solid fuel. All chimneys and or flues stove positioning and hearth size are used must be sealed for the best governed by building regulations for possible performance. class 1 appliances. The hearth must...
Inis Oirr MK2 Multifuel Boiler stove Horizontal sections of flue should be The stove is designed for open vent avoided or at least kept to a minimum. central heating systems and a gravity Horizontal flue sections from the stove feed circuit usually to the domestic hot or on any part of the flue pipe should water should be present.
Inis Oirr MK2 Multifuel Boiler stove The “Easy start” manual damper must be Initial firing closed once the stove is fully alight if the heating controls are automated. The first fire should be quite small to Please check the user manual for proper ensure prompt extinguishing of the fire operation.
Page 14
Inis Oirr MK2 Multifuel Boiler stove Item # Description Item# Description Riddler bar Damper box cover plate “Easy start” damper push rod brace Door glass Door glass clip Thermostatic damper Left Brick (part of set) Thermostatic damper drive “Easy Start” damper push rod bushing Rear Brick (part of set) “Easy Start”...
Need help?
Do you have a question about the Oirr MK2 and is the answer not in the manual?
Questions and answers