InisBofin Insert Boiler Multi-fuel Stove Congratulations on the purchase of dwelling that a carbon monoxide your new InisBofin insert boiler alarm MUST be fitted in the same stove. We here at Inis Stoves room as the appliance. Inis Stoves truly love building high quality also recommend that a fire alarm stoves for our customers.
InisBofin Insert Boiler Multi-fuel Stove Fire Brigade immediately. After a chimney fire, the chimney must be examined by a chimney expert before using the stove again. Stove Features Figure 1 below shows how to use the hand tool faces downward at 45 the stove door handle.
InisBofin Insert Boiler Multi-fuel Stove Figure 3 below shows the stove Paint Curing damper controls. Please adhere to the curing procedure described below as over- firing the stove before the paint has cured will lead to fading of the paint and this is not covered by your warranty.
InisBofin Insert Boiler Multi-fuel Stove General Points Ideally, empty the ash pan when the ashes are cold. 8. Inis Stoves is dedicated to 1. Never use liquid fuels in the the principal of using stove renewable fuels in all our 2.
InisBofin Insert Boiler Multi-fuel Stove burn brightly and have a very low Examples of these fuels are ash content usually less than 1%. “Calco” and “Superblend”. If possible, always use light dry Using any fuel containing kindling when lighting the stove.
InisBofin Insert Boiler Multi-fuel Stove get heat to the room as early as adjusted down to an appropriate possible. setting. Continuous burning Light the fire and with the door lock engaged but the door slightly ajar let the fire light up. After...
InisBofin Insert Boiler Multi-fuel Stove up in the chimney when the stove regular basis the condition of the is operated this way. door seal and if found to be worn replace it immediately. Ash clearance Only clean the stove when it is fully cold.
Page 10
InisBofin Insert Boiler Multi-fuel Stove 2. Remove 3-4 riddler bars reverse of dis-assembly. starting at the second from the back and working forward. To remove the riddler bars for airway cleaning first lift the front of each firebox side plate and swing toward the stove centre.
InisBofin Insert Boiler Multi-fuel Stove changed if needed. Also check the 2 Fuel load too small for damper setting. seal on the door glass for 3 Door seals are worn. tightness and seal integrity. 4 Adjust the damper to a lower Shutdown: setting for proper fire control.
InisBofin Insert Boiler Multi-fuel Stove required radiators and that the to, blackening of the glass should radiators don’t require bleeding. always burn off after a period of full output. A poor draught and or 4 Ask the installer to check that...
InisBofin Insert Boiler Multi-fuel Stove If at any time the Co (Carbon monoxide) alarm sounds, open all windows and doors, close down the stoves and leave the room. After it has been deemed safe to re-enter the room only after the fire has...
InisBofin Insert Boiler Multi-fuel Stove Stove installation Manual achieved using Smokeless coal (MSF) over a 2 hour refuelling Specification period. Output Kw 13.5-16.9 Health and Safety Water 12.0-14.0 precautions Room 1.5-5.0 Flue Diameter 153mm 6” Please ensure that the Flue Gas Temperature...
InisBofin Insert Boiler Multi-fuel Stove Air requirements outside or debris like leaf litter etc. A larger vent is required if there Proper air supply must be insured is an appliance like an extractor to the room into which the stove fan or tumble drier in an is to be installed.
InisBofin Insert Boiler Multi-fuel Stove It MUST be checked if using the Façade removal: external air provision that the The facade is removed (See Fig 8) base plate if fitted so that the by unscrewing of the two screws on front air grill on the front both sides of the façade at floor...
Page 17
InisBofin Insert Boiler Multi-fuel Stove must be at least 150mm diameter or 150mmx150mm square. The chimney must be in good condition, be cleaned and free from cracks and blockages. The chimney must not have too great a cross sectional area (200mm diameter maximum) and...
InisBofin Insert Boiler Multi-fuel Stove work on the chimney structure hearth of at least 12mm in depth before the liner and infill are that is flat and level. The stove used. Any flue sections used in positioning and hearth size are the installation must not have 90º...
InisBofin Insert Boiler Multi-fuel Stove Fig 10 The minimum depth of the recess for the stove from the front face should be 390mm. In most cases this will require that the removal of the fireback and the removal of loose material. The distance from the face of the fireplace to the Method 1.
Page 20
InisBofin Insert Boiler Multi-fuel Stove correct position, fire cement the end of the extension pipe and should be used to make a tapered when fully sealed, push the flue seal between the clay liner and collar up into position and bolt the adaptor to ensure any into place.
Page 21
InisBofin Insert Boiler Multi-fuel Stove flexible liner at the top of the Once the liner is fully fitted to chimney as per the manufacturer’s the stove, vermiculite infill can instructions. The stove can now be be used to fill in around the plumbed as per the section below liner down to the stove.
InisBofin Insert Boiler Multi-fuel Stove Method 2 Central Heating the Domestic hot water tank is hot. This radiator must be at System least 1kw in capacity. If there isn’t a domestic water The plumbing of the stove must be tank in the system, an unvalved...
Page 25
InisBofin Insert Boiler Multi-fuel Stove Typical 4-pipe connection piping layout Piping connections to the stove: Each flow and return on any particular circuit MUST be cross connected for the stove to operate correctly. Even when using all four connections to pipe the stove.
InisBofin Insert Boiler Multi-fuel Stove short and vertical as possible, pull stove. The main issue with using just any piping bends if at all possible one stat is that the water coming back and only use 28mm piping. If there are...
InisBofin Insert Boiler Multi-fuel Stove control the boiler temperature. It is First Firing & always an advantage to have a radiator in the same room as the stove to aid Commissioning the room heating. A small fire can now be started in the stove.
Need help?
Do you have a question about the InisBofin and is the answer not in the manual?
Questions and answers