Fasteners

SP FASTENERS

Application Chart

Power load and power fastener application information.
For fastening this
Two by fours
Furring strips
Electrical
junction boxes
Conduit clips
Shelf brackets
1/4" Plywood or
pegboard
Power load listings are recommendations only. If you are in doubt, try a test
fastening using the next lightest power load.
Wood or Non-Metals
482-78
Fasten wood or nonmetals to concrete or steel.
to this
Concrete
Cement block
Steel (3/16" to 3/8" thick)
Concrete
Cement block
Steel (3/16" to 3/8" thick)
Concrete
Cement block
Steel (3/16" to 3/8" thick)
Concrete
Cement block
Steel (3/16" to 3/8" thick)
Concrete
Cement block
Concrete
Cement block
Steel (3/16" to 3/8" thick)
482-79
To Steel
power fastener
24
Wood or Non-Metals
To Concrete
power load
length
2 1/2"
2 1/2"
2"
1 1/2"
1 1/2"
2"
1"
1"
3/4"
1"
1"
3/4"
1"
1"
1 1/4"
1 1/4"
1"
482-81a
482-80
color
Yellow
Green
Yellow/Red
Yellow
Green
Yellow/Red
Yellow
Green
Yellow/Red
Yellow
Green
Yellow/Red
Yellow
Green
Yellow
Green
Yellow/Red
099494