INDEX System information Assembly Use with a monitor - Remote control - Remote control pairing - TEK-SCOPE live streaming - How to set your monitor Use with a PC - TEK-SCOPE software - Toolbar - System set up - Measuring...
• Measurement & drawing capabilities TEK-SCOPE can be connected to any monitor with a DVI / HDMI port. When used with a computer you can install the included TEK-SCOPE Software and make measurement, drawing and much more. ASSEMBLY TEK-SCOPE package includes the following items: •...
Remote control pairing Hold the remote control on the back of the TEK-SCOPE while the power is on, then press the OK button on the remote control for 5 seconds. When a red light start flashing, the pairing procedure is complete.
The Device cannot work properly if connected to a PC and a Monitor at the same time. How to set your monitor 1. To pair TEK-SCOPE with the screen you are using: press MODE button on the remote for a couple of seconds to get into the menu.
Switzerland 2. USE WITH A PC TEK-SCOPE software Operating System: Windows 10. After installing the Software, you can access TEK-SCOPE functions: Toolbar Zoom in Freeze Brightness Focus Adjust IR Cut Draw/Measure Zoom out Save live Picture Autofocus ON/OFF Cross Stop Digital...
Switzerland System set up Example of system setup when TEK-SCOPE Software is used: DO NOT CONNECT THE DEVICE BOTH TO A MONITOR AND PC TOGETHER. If the computer and the monitor are used together, like extended or dual, the algorithm for magnification/ measuring will be effected.
If the +4 lens is used (with tilt table) do as follows: start the program, right click in the live image and choose lens, change to lens +4. Done. Next time the software will be started, it will remember this setting. If lens it changed time to time, user needs to change the lens setting. www.ideal-tek.com...
= choose the name of the image and the index will be added. Example = MyBoard_1, MyBoard_2 …. Reset index = the value after the name will be set to 1 again, Name will remain until user changes it. www.ideal-tek.com...
Available on the installation under folder \encoder. Run the setup . Then go to Encode settings, ( program Xvid) Verify that there is a folder named “\ Focus” under \\my pictures. If not, make a new folder and name it Focus. www.ideal-tek.com...
Portable XY ESD safe table for easy control of magnified object. Horizontal Movement: 190mm; Vertical Movement 235 mm; Table Dimension: 420x410 mm; Weight= 4.5 kg TEK-DBOX Image capture box When using TEK-SCOPE without a computer you can save images directly on USB Pen, using the Image capture box. www.ideal-tek.com...
TEK-DBOX installation Connect the unit as showed below. Check the IN and OUT label on the box. IN: connect the HDMI cable OUT: connect the HDMI to TEK-SCOPE cable to the monitor Connect MINI USB OUT: Connect your USB power cable...
If the product is moved from cold to warm, condensation may occur. Wait about 30 minutes before using the product. Use TEK-SCOPE only on stable work surface, with at least 45 cm depth. If normal functions can’t be reset after troubleshooting, turn power off and contact your local supplier.