Troubleshooting - MasterCool ADA51 Installation & Operation Manual

Single inlet evaporative coolers
Table of Contents

Advertisement

Available languages

Available languages

WEIGHT (lbs)
MODELS
DRY
51 Series
177
5112 Series
190
71 Series
213
7112 Series
233
*Includes motor weight
MODELS
H.P
MOTOR PN
1/3
110445
1/2
110447
1/2
110475
51 & 5112
3/4
110449
Series
3/4
110480
1/2
110447
1/2
110475
71 & 7112
3/4
110449
Series
3/4
110480
1
110471
1
110458
* Amperage shown is from National Electrical Code for high speed.
PROBLEM
Failure to start or no air delivery
Inadequate air delivery with cooler running
Water draining onto roof
Musty or unpleasant odor
Motor cycles on and off
Noisy
Inadequate cooling
Excessive humidity in house
110498-2
GENERAL SPECIFICATIONS
CABINET DIMENSIONS (in.)
OPERATING
HEIGHT
227
28
257
28
263
34-5/8
300
34-5/8
MOTOR SPECIFICATIONS
SPEED
VOLTS
*AMPS
2
115
7.2
2
115
9.8
2
230
4.9
2
115
13.8
2
230
16.9
2
115
9.8
2
230
4.9
2
115
13.8
2
230
6.9
2
115
16
2
230
8
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
1. No electrical power to unit
Blown Fuse or Tripped Circuit Breaker
Electrical cord damage
2. Belt too loose or too tight
3. Motor overheated
Belt too tight
Blower bearings dry
Motor pulley diameter too large
4. Motor locked
1. Insuffi cient air exhaust
2. Belt too loose
3. Pads plugged/dirty
4. Motor underloaded
1. Float arm not adjusted properly
2. Overfl ow assembly leaking
1. Stale or stagnate water in cooler
1. Low voltage
2. Excessive belt tension
3. Blower shaft and tight or locked
4. Bearings dry
5. Motor pulley diameter too large ,
causing motor overload
1. Bearings dry
2. Wheel rubbing blower housing
3. Loose parts
1. Inadequate exhaust in house
2. Pads not wet
Pads clogged
Distribution tube holes clogged
Pump not working properly
1. Insuffi cent air exhaust
WEIGHT
DEPTH
42
45
42
49
42
48
42
52
MOTOR PULLEY P/N
WEIGHT (LBS)
17
110279-002
18
110279-004
15
110279-004
22
110279-004
21
110279-004
18
110279-002
15
110279-002
22
110279-004
21
110279-004
29
110279-003
29
110279-003
1. Check Power
• Replace fuse or reset breaker
• Replace Cord
2. Adjust belt tension
3. Determine cause of overheating
Adjust pulley tension
Oil blower bearings
Adjust pulley to correct diameter
4. Replace motor
1. Open doors or widows to increase air fl ow
2. Adjust belt tension or replace if needed
3. Clean pads
4. Adjust pulley
1. Adjust fl oat
2. Tighten nut and overfl ow pipe
1. Drain pan and clean pads
1. Check voltage
2. Adjust belt tension
3. Unplug unit and oil or replace bearings
4. Oil bearings
5. Adjust pulley so full load ampere
rating of motor is not exceeded.
1. Oil bearings
2. Unplug unit, inspect and realign
3. Tighten loose parts
1. Open windows or doors to increase air fl ow
2. Check water distribution system
Clean pads
Clean tube holes
Unplug and replace or clean pump
1. Open doors or windows
7
DUCT OPENING (in.)
WIDTH
HEIGHT
17-3/4
17-3/4
17-3/4
17-3/4
19-3/8
19-3/4
19-3/4
19-3/4
MODEL
DRIVE BELT P/N
110208 (4L-520)
ADA51 &
ADA5112
110229 (4L-530) -3/4 HP
ASA51 &
110212 (4L-570)
ASA5112
AUA51 &
110222 (4L-510)
AUA5112
ADA71 &
110230 (4L-640)
ADA7112
ASA71 &
110213 (4L-670)
ASA7112
AUA71 &
110213 (4L-670)
AUA7112
REMEDY

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents