Page 6
Table 1 Document Versions....................5 Table 2 Related Manuals....................5 Table 3 Specifications for a Third Party Power Supply..........11 Table 4 Symbols Used in AP10 Product Markings............ 16 Table 5 Troubleshooting Table..................36 Table 6 Wireless........................ 39 Table 7 Operating Environment..................39 Table 8 Inputs and Outputs...................
M211860EN-A May 2018 First version. 1.2 Related Manuals Table 2 Related Manuals Document Code Name M211821EN AP10 Access Point Quick Guide M211820EN viewLinc Monitoring System Setup Guide M211975EN viewLinc Enterprise Server User Guide M211822EN RFL100 Data Logger Quick Guide M211861EN RFL100 Data Logger User Guide 1.3 Documentation Conventions...
Lists tools needed to perform the task. Indicates that you need to take some notes during the task. 1.4 Trademarks Vaisalaâis a registered trademark of Vaisala Oyj. The LoRa ™ name and associated logo are trademarks of Semtech Corporation or its subsidiaries.
AC/DC adapter. If both power sources are connected, the AC/DC adapter is utilized to power the device. AP10 is IP22 rated, and is suitable for indoor industrial applications. For best wireless coverage, install the AP10 at eye height or on the ceiling.
Power supply connector (10 ... 30 VDC). Service port (micro-USB). USB port for hardware expansion (USB type A). Reset button. Push to restart, push and hold to revert AP10 to factory settings. RJ-45 Ethernet port. Can be powered by Power over Ethernet (PoE).
Housing screws. Do not remove. 2.3 VaiNet Devices in viewLinc Monitoring System VaiNet access points create links between Ethernet and Vaisala devices using the VaiNet protocol. Wireless device registration is handled by viewLinc Enterprise Server. Whenever a new data logger is added to the system, it is automatically identified by an access point, which forwards the data logger’s information to the server.
AP10 User Guide M211860EN-A VaiNet wireless devices are not limited to using a single access point. If multiple access points are available, VaiNet devices can switch access points to maintain their connection to the viewLinc Monitoring System. The strength of the wireless signal is used to determine the optimum network data path.
AP10 has a supercapacitor as a backup power source for its realtime clock. If AP10 is left without power for more than a day, the realtime clock will lose its time. If this happens AP10 will have to synchronize its clock with the NTP servers before it can operate its radio. This is typically the case when an AP10 is installed - it needs to synchronize its clock before it can start to connect VaiNet data loggers.
• Approved for use in your country 2.7 Remote Management AP10 has a web interface for remote management. Additionally, some settings can be remotely managed using viewLinc Enterprise Server software. Remote management operations can be performed directly from the Sites Manager > Hosts and Devices tree.
Figure 6 AP10 Properties in viewLinc Select Sites Manager > Show hosts to see the IP addresses of all connected hosts. Select the IP address of any AP10 to open its web interface in your browser. 2.8 Regulatory Compliance 2.8.1 FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
съответствие може да се намери на следния интернет адрес: www.vaisala.com/ declarationofconformity CS: Tímto Vaisala Oyj prohlašuje, že typ rádiového zařízení AP10 je v souladu se směrnicí 2014/53/EU. Úplné znění EU prohlášení o shodě je k dispozici na této internetové adrese: www.vaisala.com/declarationofconformity DA: Hermed erklærer Vaisala Oyj , at radioudstyrstypen AP10 er i overensstemmelse med...
Page 17
Az EU-megfelelőségi nyilatkozat teljes szövege elérhető a következő internetes címen: www.vaisala.com/declarationofconformity IT: Il fabbricante, Vaisala Oyj , dichiara che il tipo di apparecchiatura radio AP10 è conforme alla direttiva 2014/53/UE. Il testo completo della dichiarazione di conformità UE è disponibile al seguente indirizzo Internet: www.vaisala.com/declarationofconformity...
Internet: www.vaisala.com/ declarationofconformity RO: Prin prezenta, Vaisala Oyj declară că tipul de echipamente radio AP10 este în conformitate cu Directiva 2014/53/UE. Textul integral al declarației UE de conformitate este disponibil la următoarea adresă internet: www.vaisala.com/declarationofconformity...
2.11 ESD Protection Electrostatic Discharge (ESD) can cause immediate or latent damage to electronic circuits. Vaisala products are adequately protected against ESD for their intended use. However, it is possible to damage the product by delivering an electrostatic discharge when touching, removing or inserting any objects inside the equipment housing.
3. Installation 3.1 AP10 Installation Location and Range In a typical indoor space, the wireless range of AP10 is at least 100 m (328 ft). In an open space without many interfering structures, the range may be significantly higher. Walls and ceilings are good locations for AP10. Line of sight is not required. If possible, place AP10 in the same floor as the data loggers.
Cable from DC power supply. 1. Connect the Ethernet cable to Ethernet port of AP10. If possible, connect to the same network where the viewLinc Enterprise Server is, so that you can verify the connection when doing the setup.
AP10 User Guide M211860EN-A 3. A setup wizard starts when AP10 is first powered up. Use the touch interface to complete the wizard: a. Select a language for the touchscreen display. b. Configure the network settings so that AP10 can join the network.
3. Connect the Ethernet cable. 4. If the Ethernet cable does not provide power, connect the DC power supply: a. Connect the plug to the power supply connector of AP10. Make sure the plug is oriented correctly and goes in all the way.
4. Touchscreen Interface 4.1 Accessing the Touchscreen Interface The display on AP10 is a capacitive touchscreen. The touchscreen interface may be locked by a PIN code. 1. Touch the screen to start using the interface. Do not wear gloves when using the touchscreen.
AP10 User Guide M211860EN-A • Middle: access point IP address and status. Touch the symbol to open the Settings screen. • Bottom: status of viewLinc Enterprise Server connection. Connected Data Loggers Figure 10 Touch Interface Data Logger Information Screen Data logger information screen shows connection and battery level status of each data logger that is connected to this access point.
1. Verify the IP address of the access point from the touchscreen interface. 2. Open a web browser. 3. In the address field of the web browser, enter https:// and the IP address of the AP10. For example: https://192.168.10.47 4. The default user interface language is English. If you want to use another language for this session, select it from the drop-down menu.
AP10 User Guide M211860EN-A Figure 19 Web Interface Display and LED Settings Screen AP10 Maintenance Figure 20 Web Interface Backup and Restore Screen...
This is convenient for testing settings, and copying the same settings to several access points. However, make sure to use a different VaiNet channel on each access point in one location. Figure 21 Web Interface Firmware Update Screen For firmware update procedure, see Updating AP10 Firmware (page 34).
AP10 User Guide M211860EN-A Figure 22 Web Interface Restart and Reset Screen Restart and Reset screen can be used to restart the access point, or reset all or some of its settings. If you reset all settings, the installation wizard starts when the access point boots up.
Chapter 5 – Web Interface Figure 23 Web Interface Support Screen Screen If Vaisala support requests a diagnostic data package from your AP10, you can retrieve it from the Support screen.
Accessing the Web Interface (page 25). b. Select > AP10 Maintenance > Restart and Reset > Restart > Restart. 2. Wait for the restart to complete and log in again to the web interface. 3. Select AP10 Maintenance > Firmware Update.
Page 37
Verify that the access point is still properly configured for your system. New settings may be available, and old settings may have changed. If the update appears to be stuck, restart the AP10 and repeat the update. If the update still gets stuck: 1.
LEDs on the Ethernet connector are flashing. Contact your local IT support. The following message is AP10 has just started up and it Wait for AP10 to synchronize shown on the display: has lost accurate time during time with the NTP (Network power off.
1. Connect the Ethernet cable. 2. If the Ethernet cable does not provide power, connect the DC power supply: a. Connect the plug to the power supply connector of AP10. Make sure the plug is oriented correctly and goes in all the way.
They will automatically rejoin the system, but their connection to viewLinc Enterprise Server will be temporarily interrupted. 1. If the AP10 is not on, power it up using the DC power supply and wait for it to complete the startup.
Technical Support Contact Vaisala technical support at helpdesk@vaisala.com. Provide at least the following supporting information: • Product name, model, and serial number • Name and location of the installation site • Name and contact information of a technical person who can provide further information on the problem For more information, see www.vaisala.com/support.
Need help?
Do you have a question about the AP10 and is the answer not in the manual?
Questions and answers