The time on the programmer must be correct. Some types have to be
adjusted in spring and autumn at the changes between Greenwich
Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for
QEG-1
example, 'Override', 'advance', or 'Boost'. These are explained in the
QEG-1S
manufacturer's instructions.
The heating will not work if the room thermostat has switched the
EN
Operating Manual
heating off. and, if you have a hot-water cylinder, the water heating
will not work if the cylinder thermostat detects that the hot water has
reached the correct temperature.
Override
Thu
07 / 02 / 2013
Extra Hour
am
Description of the device
OFF
Your single channel timeswitch provides timing control for your central
AUTO
Mode
ONCE
heating, letting you set ON and OFF periods to suit your own lifestyle.
CONT
EXT HOUR
ON1
+1
• Backlit lcD Display
+2
+3
• Real Time clock
• Up to 3 ON/OFF per day
Holidays
• automatic summertime / wintertime changeover
DAY/
PROG
RUN
TIME
OK
• Daily, weekly
• Different running modes: OFF, aUTO, ONcE, cONTINUOUS and
Select
hOlIDaYS
1)
• Manual override function
• Manual extra hour function
• 3 different pre-programmed profi les, customizable by user
• Boiler service interval indication & actions
Grässlin GmbH
Designated use
• The programmer is used to control central heating zone systems or
Bundesstraße 36
combi boilers
D-78112 St. Georgen
• Suitable for use in dry rooms only!
Germany
• Do not install in the vicinity of devices which generate inductive
Phone: +49 7724 933-0
discharges (motors, transformers, etc.)
Fax: +49 7724 933-240
www.graesslin.de
info@graesslin.de
Technical data
Dimensions h x W x D (mm)
Weight g (approx.)
Power supply
Power consumption
Power reserve
More information on our web page:
Switching capacity
http://qeg.graesslin.de/qrcode/im/qeg1/
Time display
Time setting resolution
– Time of day
– Programmes / min. switching
Programmes
Number of switchings per day
Operating temperature range
Safety Instructions
ambient temperature
humidity range
Danger! Risk of electric shock!
accuracy
Terminal capacity
Installation must be carried out by a
Z
Z
Protection type
WARNING
professional electrician!
European standards
• To avoid injuries, the device must be installed by a skilled
electrician only!
• Before changing the battery, the device must be disconnected
from the power supply!
• Please observe the national regulations and safety instructions.
• Interferences and changes to the device will invalidate the
warranty and guarantee rights.
• Maximum diameter of the conductors lines for the
2
Installation und Montage
Installation and mounting
terminals: 2 x 2,5 mm
Read and observe these instructions to guarantee a perfect function
of the device and a safe operation.
WARNING
General information
Information about the device
What is a programmer?
...an Explanation for householders (as recommended by the Energy
Savings Trust)
Programmers allow you to set 'ON' and 'OFF' time periods. Some
models switch the central heating and domestic hot water on and
off at the same time, while others allow the domestic hot water and
heating to come on and go off at different times.
Set the 'ON' and 'OFF' time periods to suit your own lifestyle. On
some programmers you must also set whether you want the heating
and hot water to run continuously, run under the chosen 'ON' and
'OFF' heating periods, or be permanently off.
1)
Function not available for all products.
80.10.1351.7_manual_QEG1_QEG1S_FERTIG_V02.indd 1
Open/Close housing, Wall mounting
1)
and week-weekend
1)
programming possibility
Wiring diagram
1)
N
L
95 x 148 x 36
285
230 V AC / 50-60 Hz
Quick-start guide – 3 clicks to total control
< 3 W
> 2h
3 a 250 V ~ resistive, cos φ = 1
1.
connect mains power.
3 a 250 V ~ inductive, cos φ = 0.6
2.
Press OK three times.
24 h or 12 h aM/PM format
Z
Z
The default Standard in-built programme runs.
You can control the QEG with the Override, Extra hour or Mode
Z
Z
buttons.
1 min.
1 min.
Selectable (daily , weekly, or
Please read the full instructions if you want to know more.
week-weekend)
3 ON/OFF pairs
(2 ON/OFF pairs selectable)
Operation and confi guration
0°c ... + 45°c
-20°c ... + 55°c
10 to 90% Rh, non condensing
Display / Function keys
Type ± 1 sec./day at +20°c
2 x 2,5 mm
2
IP 30
EN60730-2-7
07 / 02 / 2013
compliant with building regulations
(Part l Uk) (Part J Scotland)
1)
1)
Holidays
OK
Danger! Risk of electric shock!
Day of the week indicator
A
Z
Z
Installation must be carried out by a
current day, month, year
B
professional electrician!
C
central heating operating
mode indicator
D
central heating override
button
central heating extra hour
E
button
F
central heating operating
mode button
G
central heating indicator lamp
H
central heating extra hour
1.5 m
indication
Commissioning
When fi rst using the timer, you have to set programming type,
date and time.
PROG TYPE
DAY
MONTH
YEAR
HOUR
MINUTE
DONE
1.
connect the programmer to power.
Z
Z
Product name and version number are displayed briefl y.
Z
Z
The preset PROGRAMMING TYPE and OK are fl ashing.
Depending on the product you can choose between three different
settings: Daily, Weekly
or Week-Weekend
1)
Daily
all days (Monday - Sunday) are programmed
with the same ON/OFF time schedule
N L 1 2 3 4
Weekly
You can program each day (Monday, Tuesday,
1)
...) with a different ON/OFF time schedule
Week-Weekend
1)
You can program Monday - Friday with a ON/
OFF ON
OFF time schedule and Saturday - Sunday with
output
Mains
a different one.
input
2.
choose your desired programming type (DaIlY, WEEklY
WEEk-WEEkEND
),
or
, and confi rm with
1)
Z
Z
Preset value DATE is fl ashing.
3.
Enter day,
or
, and confi rm with
.
Z
Z
Preset value MONTH is fl ashing.
4.
Enter month,
or
, and confi rm with
Preset value YEAR is fl ashing.
Z
Z
5.
Enter year,
or
, and confi rm with
.
Z
Z
Preset TIME is fl ashing.
6.
Enter hour,
or
, and confi rm with
.
Z
Z
Preset value MINUTE is fl ashing.
7.
Enter minute,
or
, and confi rm with
The date and time are saved.
Z
Z
The programmer goes to RUN mode.
Z
Z
Set date and time
If you wish to change the date or time, follow the instructions below:
DAY/
PROG
RUN
TIME
DAY
Override
Thu
MONTH
am
Extra Hour
YEAR
OFF
AUTO
Mode
HOUR
ONCE
CONT
EXT HOUR
MINUTE
ON1
+1
+2
+3
HOT WATER
HEATING
Override
DONE
Override
Thu
07 / 02 / 2013
Extra Hour
am
Extra Hour
OFF
DAY/
PROG
RUN
OFF
Mode
AUTO
AUTO
Mode
TIME
ONCE
ONCE
CONT
CONT
EXT HOUR
EXT HOUR
ON1
+1
ON1
+1
+2
+2
+3
+3
Select
Holidays
DAY/
DHW
CH
RUN
TIME
OK
1.
Press the SELECT
until menu DAY/TIME is selected.
Select
central heating programming
Select indicator lamp DAY/TIME is ON.
I
Z
Z
period indication
2.
Enter day,
or
, and confi rm with
.
Preset value MONTH is fl ashing.
J
Select indicator lamps
Z
Z
K
Select
3.
Enter month,
or
, and confi rm with
L
Ok button
Z
Z
Preset value YEAR is fl ashing.
M
"-" and "+" button
4.
Enter year,
or
, and confi rm with
.
HOT WATER
HEATING
Override
Override
holiday button
Preset TIME is displayed.
Thu
N
1)
Z
Z
07 / 02 / 2013
Extra Hour
am
Extra Hour
holiday icon
5.
Enter hour,
or
, and confi rm with
.
O
1)
OFF
OFF
Mode
Mode
AUTO
AUTO
Preset value MINUTE is fl ashing.
ONCE
ONCE
P
Information text line
Z
Z
CONT
CONT
ON1
EXT HOUR
+1
EXT HOUR
+2
ON1
+2
+1
+3
+3
Q
analog clock /
6.
Enter minute,
or
, and confi rm with
current time
Z
Z
The date and time are saved.
Holidays
DAY/
DHW
CH
RUN
TIME
OK
R
Warning icon
7.
Press the SELECT
until indicator lamp RUN is ON.
Select
Change AM/PM time display to 24 hour clock
Your programmer can operate on the 12 hour aM/PM or 24 hour clock
formats.
If you wish to change the clock format, follow the instructions below:
10 sec.
INST MENU
DIGI CLOCK
12 24 HRS
1.
Make sure the device is working in RUN mode.
2.
Press and hold
buttons at the same time for 10 seconds.
Z
Z
INST MENU opens and OK is fl ashing.
3.
Confi rm with
.
The menu item DIGI CLOCK is displayed.
Z
Z
4.
Press
to edit settings.
Z
Z
Setting NO is fl ashing.
5.
Press
or
to scroll through the menu. choose YES and
confi rm with
.
.
Setting AM PM is fl ashing.
1)
Z
Z
6.
Press
or
to scroll through the menu. choose AM PM or 24
HRS and confi rm with
.
Z
Z
The chosen setting is saved.
Z
Z
The next menu item BACKLIGHT is displayed.
7.
To save your settings, continue scrolling through the menu options
with
key, until you once again see INST MENU / – OK +, and
fi nally leave the installers menu with
key.
With QEG-1S, continue scrolling through the menu options with
key, until you see CHANGE PIN / – OK +, and fi nally leave the
key.
,
1)
.
Running a built-in programme (default programmes)
With the date and time correct, your timer will now be operating to the
built-in programmes. These have been designed to provide heating at
typical times throughout the day.
.
The built-in programmes give you a starting point that you can
personalise to your own requirements, please see the section "Review/
Edit central heating program" or "Review/Edit domestic hot water
program".
Built-in programme STD (DEFaUlT)
.
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 04:30 pm
OFF1: 08:30 am
OFF2: 12:00 pm*
OFF3: 10:30 pm
Weekly
1)
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
OFF1: 08:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
Weekend
1)
OFF1: 08:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
Built-in programme HOME
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 12:00 pm*
OFF3: 11:00 pm
Weekly
1)
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
Weekend
1)
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
Built-in programme ECO
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 05:30 pm
OFF1: 07:30 am
OFF2: 12:00 pm*
OFF3: 10:00 pm
Weekly
1)
ON1: 08:30 am
ON2: 12:00 pm
ON3: 05:30 pm
.
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:00 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 05:30 pm
Weekend
1)
OFF1: 07:30 am
OFF2: 12:00 pm
OFF3: 10:00 pm
ON1: 08:30 am
ON2: 12:00 pm
ON3: 05:30 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
.
* On/off prgrammes with the same time cancel out - no switching will occur.
The built-in programmes can be selected in the INSTALLERS MENU.
To access to installers menu, the device must be working in RUN mode.
10 sec.
INST MENU
DIGI CLOCK
BACKLIGHT
S W CHANGE
PROG TYPE
1.
Make sure the device is working in RUN mode.
2.
Press and hold
buttons at the same time for 10 seconds.
INST MENU opens and OK is fl ashing.
Z
Z
3.
Confi rm with
.
Z
Z
Installers menu is activated.
4.
Press 3 x
until PROG TYPE is displayed.
5.
Press
to edit settings.
Preset value is fl ashing.
Z
Z
6.
Press
or
to scroll through the menu. choose your desired
setting (DaIlY, WEEklY
1)
, 5-2 DaYS
1)
) and confi rm with
.
Z
Z
The chosen setting is saved.
Z
Z
The next menu item NR PERIODS is displayed.
NR PERIODS
DEFAULT PROG
PUMP GRAVITY
7.
Press
to go to DEFAULT PROG.
8.
Press
to edit settings.
Preset value is fl ashing.
Z
Z
9.
Press
or
to scroll through the menu. choose your desired
setting (STD, HOME or ECO) and confi rm with
.
Z
Z
The chosen setting is saved
Z
Z
The next menu item PUMP GRAVITY is displayed.
10. To save your settings, continue scrolling through the menu
options with
key, until you once again see INST MENU / –
OK +, and fi nally leave the installers menu with
key.
With QEG-1S, continue scrolling through the menu options with
key, until you see CHANGE PIN / – OK +, and fi nally leave
the installers menu with
key.
Review/Edit central heating (CH) program
Depending on the product you can choose between three different
settings: Daily, Weekly
1)
or Week-Weekend (5-2 days)
1)
.
Daily
all days (Monday - Sunday) are programmed
with the same ON/OFF time schedule
Weekly
You can program each day (Monday, Tuesday, ...)
1)
with a different ON/OFF time schedule
Week-Weekend
You can program Monday - Friday with a ON/
1)
OFF time schedule and Saturday - Sunday with
a different one.
You can choose the desired setting in the INSTALLERS MENU.
Every programme has three pairs of ON/OFF switching times
per day. Each time can be set between 3.00 am and 2.50 am
(on the next day).
Mo - Fr
Sa - Su
Example 1: Daily programming CH, built-in programme STD
DAY/
PROG
RUN
TIME
ON1 CH
OFF1 CH
ON2 CH
OFF2 CH
Mo - Fr
ON3 CH
OFF3 CH
Sa - Su
ON1 CH
SAVED
HOT WATER
HEATING
Override
Override
Thu
07 / 02 / 2013
Extra Hour
am
Extra Hour
OFF
OFF
Mode
AUTO
AUTO
Mode
ONCE
ONCE
CONT
CONT
EXT HOUR
EXT HOUR
ON1
+1
ON1
+1
+2
+2
+3
+3
Holidays
DAY/
DHW
CH
RUN
TIME
OK
1.
Press the SELECT
until indicator lamp PROG is ON.
Select
Z
Z
Preset value ON1 (06:30) is fl ashing.
Mo - Fr
Set time:
Sa - Su
• If you make any changes, you must press OK to confi rm ALL
ON/OFF pairs before pressing the select button to return to
the RUN mode, otherwise your changes will be lost.
• Press
or
briefl y to increase/decrease the time in 1
minute steps.
Press and hold
or
longer than 2 seconds to increase/
decrease the time quickly.
Or press OK to confi rm a displayed (fl ashing) value
2.
Enter hour and minute for the new ON1 command,
or
,
and confi rm with
.
Preset value OFF1 (08:30) is fl ashing.
Z
Z
Enter hour and minute for the new OFF1 command,
3.
or
,
and confi rm with
.
Z
Z
Preset value ON2 (12:00) is fl ashing.
4.
Enter hour and minute for the new ON2 command,
or
,
and confi rm with
.
Preset value OFF2 (12:00) is fl ashing.
Z
Z
24.04.2013 11:37:31
Need help?
Do you have a question about the QEG-1 and is the answer not in the manual?
Questions and answers