6. OPERATION

Before use, please make sure the voltage and power of the appliance are
accord with the labeled power and specification of the unit to avoid any damage.
Please connect the appliance before turning on the unit. Switch on appliance
after you make sure the unit is working normally with output voltage.
When connecting the electrical appliance with motor or compressor, such
as drill, air-conditioner and so on, to the automatic voltage regulator,
please make sure that the power rating of the automatic voltage regulator
is at least 3 times of the power rating of the electrical appliance, so that it
can work smoothly, because the starting up power is much beyond of the
power rating of the electrical appliance.
Output Delay: Delay time 6 seconds (DEFAULTED) and 120 seconds
(MANUAL SWITCH) are alternative.
A U T O M A T IC V O LT
A G E R E G U L A TO R
IN P U T
O U TP U T
NOTE:
DELAY only takes effect when the system is restarted into normal.
WO RK ING
DE LA YIN G
UN US UA L
DE LA Y
UN DE LAY
M C D -1 0 0 0
V A
HOME MAIN SOCKET
5