Figure 9. Memory screens
Taking Measurements
(Refer to Figure 10)
The measurement options and screen details will vary, depending on the instrument
type you are using.
The instrument must be in the Measurement Stop mode (with red bars at the top and
bottom of the screen) before you can start a measurement.
Press the Run/Stop key ( ) to start making measurements. The screen shows green
D
bars at the top and bottom.
Figure 10. Example Stop and Run screens
Note: A Record Notes screen will appear prior to starting a measurement if Audio
Notes have been activated. Refer to User Manual for more details.
Run Screens
The Play symbol
is displayed at the top left-hand corner of the screen, and the
Pause symbol
is displayed at the bottom left-hand corner of the screen. The left-
hand soft key ( ) is the Pause/Run control and toggles between these two modes
A
when operated.
The screen displays PAUSED! when measurements are paused. The incremental
run number and its duration are displayed at the top right-hand corner of the screen. If
the Run Duration Timer is set, an icon that shows a stopwatch is displayed next to the
countdown timer. To enable or disabled the Run Duration Timer, use the Settings
screens (refer to Figure 6). If the Run Duration Timer is not set, the digital timer clock
counts up until you stop the measurement run manually (by pressing the Run/Stop
key ).
D
Figure 11. Graph and Main screens
For instruments that include this option, the broadband values can be viewed as a
bargraph or as a graphical time history on the Graph screen. Press the View key ( )
B
to toggle between the Graph and the Main screens.
Certain instrument types provide two additional Octave (or 1/3 Octave) screens (refer
to Figure 12). Use the View key ( ) to toggle the screens. Use the left/right navigation
B
keys ( ) to move across the frequency bands in the Graph view. Use the up/down
C
navigation keys to toggle between showing L and L functions
max
eq
Each bar in the graph represents an octave band measured in Hz or kHz. To view a
table of the octave values, press the View key ( ).
B
In 1/3 Octave mode, use the up/down navigation keys to change the displayed
frequencies on the table.
Some instruments in the CEL-63x range can display all the screens shown in
Figure 11 and Figure 12.
The Marker screen allows you to tag noise data and record audio, for example noise
Figure 12.
1/3 Octave
graph and list views
from a road vehicle, with a specific identity using one of four markers.
When the measurement run has finished, press the Run/Stop key ( ). A screen is
D
displayed asking you to confirm the action - press Yes to end the run.
Storage
Switch the CEL-63x instrument off when you are not using it to record measurements,
and remove the batteries if the instrument will not be used for extended periods of
time.
Always protect the instrument from physical damage and from water.
To protect the microphone, you should always keep the windshield fitted.
More information
For more information about any of the topics summarised in this Quick Start guide and
additional functions, refer to the User Manual.
Instrument types
Table 1 below lists the instrument types and shows the capabilities of each
instrument in the range. Please remember that the features that are available to you
and the screens that you can see depend on the type of instrument you are using.
Application
Model number
Cumulative Results
Period Results
Profile Results
Statistical Parameters (Ln%)
Audio Notes
Marker Events
Level Events
External Events
SLM Mode
ONLINE Mode
NNR Mode
Timers
Table 1. CEL-63x instrument types, applications and capabilities
CASELLA MEASUREMENT
Regent House, Wolseley Road, Kempston, Bedford, MK42 7JY, U.K.
Phone: +44 (0) 1234 844 100
Fax: +44 (0) 1234 841 490
E-mail for technical support: techsupport@casellacel.com
For online Technical Support: http://supportdesk.casellacel.com
Document number FG40-04
© 2011 Casella Measurement
www.casellameasurement.com
Field Guide
CEL-63x Series Sound Level Meters
1
2
3
4
B
5
7
A
6
1. Windshield (covering the removable microphone)
2. Removable amplifier
5. Soft keys and
A
B
3. On/Off key
6. Navigation keys
4. Display
7. Run/Stop key
Figure 1. The CEL-63x series
Introduction
This Quick Start guide helps you to familiarise yourself with the CEL-63x instrument
quickly, so that you can begin to use it without delay.
The guide assumes this is the first time you have used the instrument. It therefore
includes instructions to install the batteries, switch ON and set up the instrument to be
ready for use, calibrate it, take measurements, and store it safely.
We want you to get the best possible performance from the CEL-63x instrument, and
we recommend you refer to the Operator's Manual for detailed information.
Think Environment. Think Casella.

Advertisement

loading

Summary of Contents for CASELLA CEL CEL-630

  • Page 1 Note: A Record Notes screen will appear prior to starting a measurement if Audio Instrument types Notes have been activated. Refer to User Manual for more details. Table 1 below lists the instrument types and shows the capabilities of each instrument in the range.
  • Page 2 Fit the batteries Set language (Refer to Figure 2) Measurement control (Refer to Figure 6) Select Settings and press to continue. Use navigation keys to select the Select Settings and use the navigation keys to select the Measurement control The CEL-63x instrument requires three AA batteries. Language symbol .

This manual is also suitable for:

Cel-632Cel-633Cel-631