Download Print this page

AMX IRIS Installation Manual page 2

Ir/serial data capture device
Hide thumbs Also See for IRIS:

Advertisement

3.
Simultaneously press and release the
mode setting On and Off. The display then shows an On or Off message indicating the
new P mode setting and then immediately exits the P mode. You can activate multiple
P modes to capture an HC function; refer to the Default Mode Settings table for the P
mode default settings when you connect power to the IRIS unit.
4.
Repeat the Capturing HC functions in default mode steps 3 through 6, to capture the
HC function.
Display Characters and P Mode Settings .
Display Characters and P Modes
Characters Description
[ ]
HC function is captured, analyzed, stored, and verified.
Er
Error: HC function did not verify correctly.
Nd
No Device. Communication device error detected, or the IREdit program is
not staged to receive HC functions.
NO
Normal Operation. Ready to capture HC.
OF
P mode is off.
On
P mode is on.
So
Send OK. HC function sent without errors to a PC running IREdit.
SP
Special Function. Special mode to capture unusual HC functions.
P1-P2
Not used.
P3
Sends HC functions to a PC running IREdit automatically after the VERIFY
operation.
P4
Disables the VERIFY operation to capture HC functions.
Default mode requires the VERIFY operation.
P5
Loose-timing mode to capture JVC (PQ10956) HC functions.
P6
Glitch-detection mode to capture Kinderman and some Mitsubishi HC func-
tions.
P7
Disables glitch-detection mode to capture non-carrier HC functions.
P8
Strict-timing mode
Baud Rate Settings
The default communication setting for the IRIS unit is 9600 baud. You can change the baud
rate with the
,
, and
pushbuttons. You must set the IRIS unit's baud rate to
UP
DOWN
SEND
match the baud rate of the PC running the IREdit software program to store HC functions.
Note: The IRIS unit automatically sets the baud rate to 9600 when you connect power. If you
reset the baud to any other setting and disconnect power, the previous baud rate setting is
lost and the IRIS unit will default back to 9600 baud.
To set the baud rate:
1.
Disconnect the power supply from the IRIS unit.
2.
Press and hold the
,
, and
UP
DOWN
release the pushbuttons.
3.
The two digits that appear in the display represent the current baud rate setting. The
following table lists the RS-232 baud rates and corresponding display digits:
Baud Rate and Display Digits
Baud Rate
Display Digits
300
600
1200
2400
4800
9600
4.
Press the
or
pushbuttons to reset the baud rate.
UP
DOWN
5.
Press and hold the
,
, and
UP
DOWN
The
lights to indicate the IRIS unit is ready to capture an HC function.
READY LED
HC IR Functions
HC IR Functions - Standard Order
Function Description
1
Play >
2
Stop [ ]
3
Pause | | or still
4
Ffwd >> (AMS/skip track/
chapter)
5
Rewind << (AMS/skip track/
chapter)
6
Search fwd >>| (AMS/scan)
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2012 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
,
, and
pushbuttons to toggle the P
UP
DOWN
SEND
pushbuttons. Reconnect the power supply and
SEND
03
06
12
24
48
96
pushbuttons again to set the new baud rate.
SEND
Function Description
22
Channel up or +
23
Channel down or -
24
Volume up or +
25
Volume down or -
26
Mute
27
On (power typically)
3/12
AMX reserves the right to alter specifications without notice at any time.
HC IR Functions - Standard Order (Cont.)
Function Description
7
Search rev |<< (AMS/scan)
8
Record
9
Power or on/off
10
'0' or '10'
11
'1' (channel digits or tracks
for CD)
12
'2'
13
'3'
14
'4'
15
'5'
16
'6'
17
'7'
18
'8'
19
'9'
20
'+10' or '+100'
21
Enter (typically used in
conjunction with number)
Cables and Adapters
Depending on your IREdit programming configuration, one or more cables may be required.
Connectors are shown from the wiring side.
FIG. 2 shows a computer-to-Control System (DB-25 to DB-9) wiring diagram;
2
3
7
25-pin PC serial-port connector
FIG. 2
Computer-to-Axcess Control System (DB-25 to DB-9) wiring diagram
FIG. 3 shows a computer-to-Central Controller (DB-9-to-DB-9) wiring diagram.
2
3
5
9-pin PC serial-port connector
FIG. 3
Computer-to-Axcess Control System (DB-25 to DB-9) wiring diagram
Troubleshooting
E1 or ER messages
The Er/E1 message appears when there is a communication problem with the PC and not an
error in capturing the IR functions.
E1 or Er Messages
Problem
A Hand Control can't seem to capture
the codes.
The AXB-IRIS is able to verify the
codes, but when the Send Command
is pressed, an Er appears on the
unit's display.
Function Description
28
Off (power typically)
29
TV/Video or TV/VCR or TV/LDP
(one button source selection)
30
TV
31
Video1, Line A, VCR1, VDP, or
input +
32
Video2, Line B, VCR2, or input -
33
Video3
34
RGB1 or Tape1
35
RGB2 or Tape2
36
CD
37
Tuner
38
Phono
39
Aux
40
AM/FM
41
Play < (play reverse)
42
A/B
5
3
2
9-pin Control System
or IRIS connector
5
3
2
9-pin Control System
or IRIS connector
Solution:
• Using NetLinx Studio: Go into the Device
Manager dialog box and change the COM port
settings. Verify that the new settings are as
follows: 9600, No Parity, 8 data bits, 1 stop bit,
and Flow Control is set to None.
• Using IREdit: This program is recommended for
use with this product and can also be used if the
Studio application changes (mentioned above)
do not work.
93-5448-01