8-3/4"
MAX.
Cutout depth
PK7500Df
23-1/2" MIN
Junction box
Profile
Series 27" Built-In Double Convection Wall Oven
™
location
Dimensions anD installation information (in inches)
Most 30" Wall Cabinets Can be used
With this unit.
44" to
note: These ovens are not approved for
bottom of
stackable installations. Cabinets installed
junction box
adjacent to wall ovens must have an adhesion
F
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face.
Conduit
Cabinets and drawers on adjacent 45° and 90°
40"
walls should be placed to avoid interference
with the handle.
Electric wall ovens are not approved for
E
installation with a plug and receptacle.
They must be hard wired in accordance
with installation instructions.
22"
installation inforMation:
Before installing, consult installation
instructions packed with product for
D
current dimensional data.
Side-by-side installations require at
least 2" between cutouts.
2 x 4 or
equivalent runners
KW rating
level with bottom of cutout
and ush with sides of cutout
or solid bottom oor.
240V 7.2
208V 5.4
breaKer size
240V 30 Amps
208V 30 Amps
Cutout width
25" MIN.
25-1/4" MAX.
8-3/4"
MAX.
B
Cutout width
Cutout depth
23-1/2" MIN
25-1/4" MAX.
Junction box
location
B
44" to
bottom of
junction box
27''
Cabinet
A – Overlap of oven at top of cutout
Cabinet
A – Overlap of oven at top of cutout
B – Overlap of oven over side of edges of cutout
B – Overlap of oven over side of edges of cutout
C – Overlap of oven at bottom of cutout
C – Overlap of oven at bottom of cutout
Oven
Oven
D – Install depth
D – Install depth
E – Overall height with trim
E – Overall height with trim
F – Overall width
F – Overall width
For answers to your Monogram,
or GE
®
at geappliances.com or call GE Answer Center
service, 800.626.2000.
A
25" MIN.
Cutout height
49-11/16" MIN.
50-1/8" MAX.
A
Cutout height
C
49-11/16" MIN.
Recommended
50-1/8" MAX.
minimum
cutout location
from the oor
C
Recommended
13-1/4"
minimum
cutout location
from the oor
13-1/4"
27''
CK7500
PK7500
JK5500
CK7500
PK7500
PK7500
JK3500
JK5500
27"
JK3500
1"
27"
1"
1"
1"
1"
1"
23-1/2"
23-1/2"
51-1/8"
51-1/8"
26-3/4"
26-3/4"
GE Profile
®
™
appliance questions, visit our website
®
F
Conduit
E
22"
23" minimum
door opening
23" minimum
door opening
allowance
allowance
C L
2 x 4 or
equivalent runners
C L
level with bottom of cutout
and ush with sides of cutout
or solid bottom oor.
Suitable
bracing
(must support 375 lbs.)
to support
runners
Suitable
bracing
(must support 375 lbs.)
to support
runners
F
8-3/4"
MAX.
Cutout depth
Conduit
23-1/2" MIN
40"
Junction box
location
40"
E
44" to
bottom of
junction box
22"
D
D
2 x 4 or
equivalent runners
level with bottom of cutout
and ush with sides of cutout
or solid bottom oor.
Listed by
Underwriters
Laboratories
Specification Revised 5/15
B
Ca
A
B
C
Ov
D
E
F
Need help?
Do you have a question about the PK7500DF and is the answer not in the manual?
Questions and answers