Drieaz LGR 7000XLi Owner's Manual

Hide thumbs Also See for LGR 7000XLi:

Advertisement

Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 www.legendbrandseurope.com
Dri-Eaz® dehumidifiers reduce humidity in enclosed environments by removing water vapor
from the air. This unit is rugged, durable and highly portable, making it ideal for water damage
restoration, structural drying, construction, and other applications requiring temporary, high-
performance dehumidification.
SAFETY INSTRUCTIONS
WARNING
WARNING! Do not alter or modify your dehumidifier
in any way. Use only replacement parts authorized
by Dri-Eaz Products, Inc. Modifications or use of
unapproved parts could create a hazard and will
void your warranty. Contact your authorized
distributor for assistance.
WARNING! Electric shock hazard, rotating fan
hazard and hot surface hazards.
 Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
 Must be earthed. Insert three-prong plug on power
cord into a matching electrically earthed outlet. Do
not use adapter. Never cut off third prong. Do not
use an extension cord.
 The unit must be operated on a 230V or 110V outlet
(as appropriate) circuit protected by a Residual
Current Device device.
 Keep motor and wiring dry.
 Always unplug unit before cleaning or servicing.
 Do not attempt to repair the unit. For service, contact
your local distributor.
FIRE HAZARD
 Keep away from open flames and heat sources.
 Do not use or store where vapors from gasoline,
solvents, thinners or other flammable materials may
be present.
07-01802H F412-230V EU F412-110V UK
Owner's Manual
LGR 7000XLi Dehumidifier
Original Instructions
Models F412-230V EU & F412-110V UK
LEGEND BRANDS HOLDINGS LTD.
22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS
Patents: http://www.LBpatents.com
R E A D T H E S E I N S T R U C T I O N S
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by
country/market. Contact your local distributor for
assistance. Registration allows us to better assist you
with using, maintaining or servicing your equipment and
to contact you in case we have important safety
information concerning your Dri-Eaz product. If you
determine service is required, have your equipment
model, serial number and original proof of purchase
available and ask for assistance with obtaining a return
material authorization (RMA).
GROUNDING INSTRUCTIONS
This unit's plug must be inserted into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs
provided with the appliance – if the plugs do not fit
the outlets, have proper outlets installed by a
qualified electrician.
This equipment is for use on circuits with a nominal
rating of no more than 230V or 110V (as appropriate).
Handle the unit carefully
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough
treatment can damage the unit, and may create a
hazardous condition or void the warranty.
This unit intended for household and commercial use.
1
Legend Brands Holdings, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LGR 7000XLi and is the answer not in the manual?

Questions and answers

Summary of Contents for Drieaz LGR 7000XLi

  • Page 1 Owner’s Manual LGR 7000XLi Dehumidifier Original Instructions Models F412-230V EU & F412-110V UK LEGEND BRANDS HOLDINGS LTD. 22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 www.legendbrandseurope.com Dri-Eaz® dehumidifiers reduce humidity in enclosed environments by removing water vapor from the air.
  • Page 2: Parts Identification

    CONTROLS AND OPERATING your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out INSTRUCTIONS of the unit. For more information about creating an optimum drying environment, contact your local Set unit upright distributor.
  • Page 3: Control Panel

    NOTICE: Uncoil and straighten the entire drain hose. Do Once the compressor delay countdown and self- not leave any part of the hose coiled and do not place diagnostics are complete, the display will switch to the end of the hose higher than 6 m above the bottom of normal display mode.
  • Page 4 Changing settings and viewing system information value. Press DISPLAY MENU again to accept the setting and re-start the display cycle Display setting changes and system information can be accessed by pressing DISPLAY MENU. Each press Note that only menu items followed by a greater-than of the key will display the next parameter (see list symbol ( >...
  • Page 5: User Settings

    USER SETTINGS Only menu items followed by a greater-than symbol (>) may be adjusted. If no keys are selected for 5 minutes on screens: INLET OUTLET, GRAIN DPR (INLET-OUTLET for 230V models), the display will return to normal display mode. In all the other menu items, the display with return to the normal display mode after 20 seconds.
  • Page 6: Transportation And Storage

    Normal Display: AT THE END OF THE JOB UNIT ON 00 HRS INLET XX° C To reduce the possibility of drips when moving the unit, follow these additional steps to ensure that all Wait until the control shows the normal display before water is removed from the unit.
  • Page 7 NOTICE: The unit is fitted with sensitive electronic soft cloth to remove any debris. Take care not to sensors. Protect the sensors and their lead wires from damage any interior components. damage and do not expose them to water or cleaning To maintain appearance, wipe interior and exterior solution.
  • Page 8: System Messages

    SYSTEM MESSAGES The Control Panel will display the following messages based on system performance and environmental conditions. User action, if any is required, is indicated in the third column. C O N T R O L P A N E L E X P L A N A T I O N U S E R A C T I O N M E S S A G E...
  • Page 9: Error Messages

    ERROR MESSAGES If the control system detects an error, it will produce an error (“ER”) message. If this occurs, first unplug the unit and then plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the error message reappears, refer to the explanations and solutions shown below.
  • Page 10: Specifications

    SPECIFICATIONS LGR 7000XLi LGR 7000XLi Model F412-230V EU F412-110V UK Weight (with cord and hose) 49 kg 49 kg Dimensions (H × D × W) 85 × 51 × 51 cm 85 × 51 × 51 cm Amperage 4.0A 8.0A...
  • Page 11: Electrical Schematic

    ELECTRICAL SCHEMATIC 07-01802H F412-230V EU F412-110V UK Legend Brands Holdings, Inc.

Table of Contents