Eonboom AHD-FD series User's Installation And Operation Manual

Hide thumbs Also See for AHD-FD series:

Advertisement

User's
User's
User's
User's installation
Important
Important
Safeguards
Safeguards
Important Safeguards
Important
Safeguards and
Do not place heavy objects on the DVR.
Do not let any solid or liquid fall into or infiltrate the DVR
Please brush printed circuit boards,connectors,fans,machine box and so on regularly.Before the dust
cleaning please switch off the power and unplug it.
Do not disassemble or repair the DVR by yourself.Do not replace the components by yourself.
Environment
Environment
Environment
Environment
Please place and use the DVR between 0℃ and 40℃.Avoid direct sunlight.Stay away from heat source.
Do not install the DVR in the damp environment.
Do not use the DVR in smoky or dusty environment.
Avoid collision or strong fall.
Please insure the DVR level installation in a stable workplace.
Please install in ventilated place.Keep the vent clean.
Use within the rating input and output scope.
1 Production Introduction........................................................................................................................................ 4
1.1 Product overview....................................................................................................................................... 4
1.2 Main functions............................................................................................................................................ 4
2 Open-package check and cable connections...................................................................................................5
2.1 Open-package check................................................................................................................................ 5
2.2 Hard disk installation................................................................................................................................. 7
2.3 Frame installation...................................................................................................................................... 7
2.4 Front panel............................................................................................................................................... 10
2.5 Rear panel................................................................................................................................................ 10
2.6 Audion and video inprut and output connections................................................................................17
2.6.1 Video input connections.............................................................................................................. 17
2.6.2 Video output connctions asn options........................................................................................ 17
2.6.3 SDI video input............................................................................................................................. 18
2.6.4 Audion signal input.......................................................................................................................18
2.6.5 Audion signal output.................................................................................................................... 18
2.7 Alarm input and output connections..................................................................................................... 18
2.7.1 Alarm input port specification..................................................................................................... 20
2.7.2 Alarm output port specification................................................................................................... 21
installation
installation
installation and
and
and
Warding
Warding
and Warding
Warding
and
and
operation
operation
and operation
operation Manual
Directory
Directory
Directory
Directory
第 1页
Manual
Manual
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AHD-FD series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eonboom AHD-FD series

  • Page 1 User's User's installation installation operation operation Manual Manual User's User's installation installation and and operation operation Manual Manual Important Important Safeguards Safeguards Warding Warding Important Important Safeguards Safeguards and and Warding Warding Do not place heavy objects on the DVR. Do not let any solid or liquid fall into or infiltrate the DVR Please brush printed circuit boards,connectors,fans,machine box and so on regularly.Before the dust cleaning please switch off the power and unplug it.
  • Page 2: Table Of Contents

    2.7.3 Alarm output port relay parameters................... 21 2.8 Speed dome connections........................21 3 Basic operation..............................22 3.1 Turn on..............................22 3.2 Turn off..............................23 3.3 System login.............................23 3.4 Preview..............................24 3.5 Desktop shortcut menu...........................24 3.5.1 Main menu.............................25 3.5.2 Playback............................26 3.5.3 Record control..........................27 3.5.4 Alarm output..........................28 3.5.5 PTZ comtrol...........................29 3.5.6 Color setting..........................34...
  • Page 3 4.5.2 Account............................82 4.5.3 Online user............................85 4.5.4 Output adjust..........................86 4.5.5 Auto maintain..........................86 4.5.6 Restore............................86 4.5.7 Upgrade............................87 4.5.8 Device Info............................ 87 4.5.9 Import/Output..........................87 4.6 Info................................88 4.6.1 HDD info............................88 4.6.2 BPS..............................89 4.6.3 Log..............................89 4.6.4 Version............................90 4.7 Shut down system...........................
  • Page 4 1 1 1 1 Production Production Production Introduction Introduction Production Introduction Introduction Product Product overview overview 1.1 Product Product overview overview The series DVR is designed specially for security and defence field which is an outstanding digital surveillance product. It introduces embedded LINUX operating system which is more stable. It introduces standard H.264mp video compressed format and G.711A audio compressed format which insures the high quality image, low error coding ratio and single frame playing.
  • Page 5: Open-Package Check

    ·individual real-time video recording as well as searching, playback, network surveillance, recording check, downloading and so on ·multi-playback mode ·zoom at arbitrary region Net operating operating operating operating ·through net tele-surveillance in the real time ·tele-PTZ control ·tele-recording check and real-time playback Alarm linka Alarm...
  • Page 6: Front Panel

    ♦ The key function specification in the front panel and the interface specification in the real panel are in the specification. ♦ Please check the product type in the front panel whether is accordant with the product type you order. label label label in in in in the...
  • Page 7: Rear Panel

    2.4 Rear panel T T T T h h h h e e e e r r r r e e e e a a a a r r r r p p p p a a a a n n n n e e e e l l l l o o o o f f f f T T T T s s s s e e e e r r r r i i i i e e e e s s s s Video Input Video Audio Output...
  • Page 8 rear panel panel of of of of A A A A series series The rear rear rear panel panel series series Video Input Video Output Audio Output Audio Input Network RS485 Power 第 8页...
  • Page 9 The rear rear rear rear panel panel panel panel of of of of C C C C series series series series Video Input Video Output Audio Input Audio Network Output RS485 Power Video Input Video 12V Output Output Audio Input * * * * 第9页...
  • Page 10 The rear rear rear rear panel panel panel panel of of of of E E E E series series series series 第10页...
  • Page 11 5004E-S Video Output Audio Input Network External Interface Power Supply Switch Video Output Audio Output 12V Input * * * * rear rear panel panel panel of of of of F F F F series series series The rear rear panel series 第11页...
  • Page 12 Video Input Audio Input Network External Interface Power Supply Switch Video Output Audio Output rear panel panel of of of of K K K K series series The rear rear rear panel panel series series Power Switch Power Supply Video Input Network External External...
  • Page 13 Video Input Audio Input HDMI Network External Power Supply Interface Power Switch Video Audio Output Output Video Input Video HDMI Output Network External Power Power Switch Interface Supply Audio Input Audio Output * * * * this this series products have same rear...
  • Page 14 2.6 Audio Audio Audio Audio and and video video video video input input input input and and output output output output connections connections connections connections 2.6.1 2.6.1 Video Video input input connections connections 2.6.1 2.6.1 Video Video input input connections connections The video input port is BNC connector plug.
  • Page 15 configuration). When replace the monitor by the computer display, there are some issues to notice 1、Do not stay in the turn-on state for a long time. 2、Keep the computer display normal working by demagnetizing regularly. 3、Stay away from the electro magnetic Interference. TV is not a credible replacement as a video output.
  • Page 16 * * * * note:T note:T note:T note:T series series series series have have have have no no alarm alarm alarm alarm input/output input/output input/output input/output functions. functions. functions. functions. 1..Alarm Alarm Alarm Alarm input input input input Alarm input is grounding alarm input.
  • Page 17 (1) alarm input 1,2,3,4 (2) ground (3) RS232 (4) RS485 (5) alarm input 5,6,7,8 (6) ground (7) alarm output sixteen sixteen sixteen sixteen external external external external alarm alarm alarm alarm interface interface interface interface ①⑥⑧alarm input ②⑦ground ③alarm output ⑤RS485 ④RS232 Parameter...
  • Page 18: Alarm Output Port Relay Parameters

    supply) . The grounding of the alarm and the DVR should be shared. The NC port of the alarm sensor must be connected with the DVR alarm input port. The grounding of the power supply and the alarm sensor must be shared when used in external power supply.
  • Page 19: Basic Operation

    the 485 interface of eight external alarm the 485 interface of sixteen external alarm 2.Connect the video line with the DVR video input. 3.Electrify the speed dome 3 3 3 3 Basic Basic Basic operation operation Basic operation operation Note: The button in gray display indicates nonsupport. 3.1 Turn Turn Turn...
  • Page 20: Turn Off

    Suggest using the UPS to protect the power supply under allowable conditions. Turn Turn 3.1 Turn Turn off There are two methods to turn off the DVR. Entering [main menu] and choosing [turn off] in the [turn off the system] option is called soft switch. Pressing the power supply switch is called hard switch. Illumination: 1、Auto resume after power failure If the DVR is shut down abnormally, it can automatically backup video and resume previous...
  • Page 21: Preview

    Picture 3.1 System Login Password Password Password Password protection: protection: protection: protection: If If If If the the password password password password is is is is continuous continuous continuous continuous wrong wrong wrong wrong three three three three times, times, times, times, the the alarm...
  • Page 22: Main Menu

    Shortcut menu in full analog(DVR)/Hybrid(HVR) mode 3.5.1 3.5.1 3.5.1 3.5.1 Main Main Main Main menu menu menu menu When you login, the system main menu is shown as below. 第 25页...
  • Page 23: Playback

    Picture3.3 Main Menu 3.5.2 3.5.2 3.5.2 3.5.2 Playback Playback Playback Playback There are two methods for you to play the video files in the hard disk. 1、 In the desktop shortcut menu. 2、 Main menu>Record->Playback Note: hard disk that saves video files must...
  • Page 24: Record Control

    【Playback control】See detail in below chart Function Function Function Function Function Function Function Function Play/Pause Backward play Slow forward Fast forward Previous frame Next frame Previous file Next file Round play Full screen Stop Picture 3.5 Playback control key Note: Note: Note: Note: play...
  • Page 25: Alarm Output

    Picture 3.8 Record Mode 【Schedule】Record according to the configuration. 【Manual】Click the all button and the according channel is recording no matter the channel in any state. 【Stop】Click the stop button and the according channel stops recording no matter the channel in any state.
  • Page 26: Ptz Comtrol

    3.5.5 3.5.5 control control 3.5.5 3.5.5 PTZ PTZ control control *T *T *T *T series series series function function series no no PTZ PTZ function function *PTZ *PTZ *PTZ *PTZ control control control control is is is is a a a a little little little little different...
  • Page 27 【Set】Enter the function operation menu. 【Page switch】Switch between different pages. Special Special functions functions Special Special functions functions: 1 1 1 1 、Preset Preset Preset Preset Set a location for the preset, calls the preset points, PTZ automatically turns to the setting position 1)Preset option Set a location for the preset, procedure is as follows:...
  • Page 28 Value input blank Picture 3.12 PTZ Control 2 2 2 2 、Cruise Cruise Cruise between between Points Points Cruise between between Points Points Multiple preset points connected cruise lines, call cruise between points, the PTZ run around on the line 1)Cruise Between Points Settings Cruise lines is connected by multiple preset points, setting procedure is as follows: Step1: In Picture 3.10, the Direction key will turn PTZ to designated location , click Settings...
  • Page 29 Preset Points Blank Cruise Button Time interval Cruise Line Blank Picture 3.13 Cruise Between Points Settings 2)The Calls of Cruise between Points In Picture 3.10, click Page Shift button, enter PTZ control menu as shown in Picture 3.12. Please input the number of cruise in the value blank, then click Cruise between Points button, PTZ begins to work on the cruise line.
  • Page 30 2)Scan Calls In Picture 3.10, click Page Shift button, then enter PTZ control menu as shown in Picture 3.12. Please input the number of scan in the value blank , then click Scan button,PTZ begins to work on the scan line . Click Stop button to stop. 4 4 4 4 、Boundary Boundary Boundary...
  • Page 31: Color Setting

    5 5 5 5 、Horizontal Horizontal Horizontal Rotating Rotating Horizontal Rotating Rotating Click Horizontally Rotating button, PTZ begins to rotate horizontally (relative to the original position of the camera). Click the Stop button to stop. 6 6 6 6 、Rotate Rotate Rotate Rotate...
  • Page 32: Output Adjust

    parameters include: tonality, brightness, contrast, saturation. You can set different parameters at different time sections. Picture 3.18 Color Setting 3.5.7 Output Adjust 3.5.7 3.5.7 3.5.7 Output Output Output Adjust Adjust Adjust *Hybrid *Hybrid mode mode mode is is is is with with with black...
  • Page 33: Window Switch

    menu]. Picture 3.20 Logout/Shutdown/Reboot the system 【logout】Quit the menu. Offer password next entrance. 【shut down】Quit the system. Turn off the power supply. When press the shut down button, there is schedule hint. After three seconds, the system is shut down. Cancel midway is of no effect. 【reboot】Quit the system.
  • Page 34 Preview in single window/four windows/sixteen windows according to your choice. Note Note Note Note:Different Different Different Different video video video video input input input input number number number number have have have have different different different different preview preview preview preview screen.
  • Page 35: Main Menu

    4 4 4 4 Main Main Main menu menu Main menu menu Main Main menu menu navigation navigation 4.1 Main Main menu menu navigation navigation Main Main Main Main menu menu menu menu Sub menu menu menu menu Function Function Function Function Config...
  • Page 36 Set algorithm rule: trajectory display、sensitivity、minimum pixel、alert Intelligent mode, and setting linkage parameters:period、 alarm output、 the screen prompt、record、PTZ、tour、buzzer、EMAIL、FTP upload. analysis Note Note: : : : 6000 6000 series support this function Note Note 6000 6000 series series series support support support this this this function function...
  • Page 37 Set channel mode, check channel status and configure the digital Digital channel, etc. Note Note Note Note:only only only only HVR HVR and and 6000 6000 6000 6000 series series series series support support support support Hard disk Set appointed hard disk as read-write disc, read-only disc or redundant management disc, clear data, resume date and so on User...
  • Page 38: Record

    Note Note Note:T T T T series series series have have shut shut down down Logout, shut down or reboot Note series have have no no shut shut down down Shut down function function function function Record Record 4.2 Record Record Operations related...
  • Page 39: Playback

    Manual: Manual: Manual: Manual:Click the button and the according channel is recording no matter the channel in any state. Stop: Stop: Stop: Stop:Click the stop button and the according channel stops recording no matter the channel in any state. 【Period】Set the time section of common recording, The recording will start only in the set range. 【Record type】Set recording type: regular, detection or alarm.
  • Page 40 Picture 4.2 Backup 【Detect】Detect the storage connected with the DVR such as hard disk or universal disk. 【Backup】Click backup button and the dialog box is popped up. You can choose the backup file according to the type, channel and time. Backup R R R R e e e e m m m m o o o o v v v v e e e e :Clear the file information.
  • Page 41: Snapshot

    Backup format Backup Backup Backup format format format:configurate the backup file format,according to require,can choose Start/pause Start/pause Start/pause Start/pause:Click the play button to start the backup and click the pause button to stop the backup. Note Note Note Note:During backup you can exit the page layout to carry out other functions. 【Burning】the file will be burned synchronously after click it.
  • Page 42: Alarm

    Schedule Schedule Schedule Schedule:Realise snapshot according to record type(regular,detect and alarm)and period Manual Manual Manual Manual:No matter what the present channel is in a state,once choose"manual"button,it will have snapshot at related channels. Stop Stop Stop Stop:No matter what the present channel is in a state,once choose "stop"button,it will stop snapshot at related channels.
  • Page 43 Video detect in Hybrid mode 【Channel】Choose the set motion detect channel. 【Enable】■ means that the motion detect function is on. 第 46页...
  • Page 44 【Sensitivity】Choose in the six options according to the sensitivity. Note: Note: Note: Note: Only Only Only Only the the motion motion motion motion detect detect detect detect under under under under hybrid hybrid hybrid hybrid mode mode mode mode/ / / / full full full full analog...
  • Page 45 【Interval】Only one alarm signal is turned on even there are several motion detect signals in the set interval. 【Alarm output】 Start the external equipment of corresponding linkage alarm when the motion detect alarm is turned on. 【Delay】Delay a few moments and stop when the alarm state is turned off. The range is 10~300 seconds.
  • Page 46: Video Blind

    Note Note Note Note:FTP upload need be set at [Netservice] 【Buzz】When alarm happens, device will come out with buzz. 4.3.2 4.3.2 Video Video Blind Blind 4.3.2 4.3.2 Video Video Blind Blind When the video image is influenced by the environment such as bad brightness or reaching the set sensitivity parameter, the camera mask function is turned on and the linkage function is turned on.
  • Page 47: Video Loss

    4.3.3 4.3.3 Video Video Loss Loss 4.3.3 4.3.3 Video Video Loss Loss When the equipment can not obtain the channel video signal, the video loss alarm is turned on and the linkage function is turned on. * Same * Same motion motion detect...
  • Page 48: Alarm Input

    Video loss in Hybrid(HVR) mode Pic 4.9 Video loss Set method: refer to chapter 4.3.1. Motion detect 4.3.4 4.3.4 4.3.4 4.3.4 Alarm Alarm Alarm Alarm input input input input When the equipment obtains the external alarm signal, the alarm function is turned on. 第...
  • Page 49 *Alarm *Alarm input input input is is is is the same same between between hybrid hybrid mode mode mode & & & & full full full digital digital mode, mode, function function enable, enable, when when when it it it it *Alarm *Alarm input the same...
  • Page 50: Alarm Output

    Set method: refer to chapter 4.3.1. Motion detect 4.3.5 4.3.5 4.3.5 4.3.5 Alarm Alarm Alarm Alarm output output output output Refer to chapter 3.5.4. 4.3.6 4.3.6 4.3.6 4.3.6 Abnormal Abnormal Abnormal Abnormal Analysing and inspecting current software and hardware of the device: When some abnormal events happen,the device will make a relative answer such as show message and buzzer.
  • Page 51 this this function function function is is is is enabled, enabled, enabled, then then video video blind blind blind is is is is invalid. invalid. invalid. this this function enabled, then then video video blind invalid. Pic 4.12 Intelligent analysis setting page 【Channel No.】only shows by “1”,at present, only the 1 channel with maximum resolution of 1080P in the full analog(DVR) mode and hybrid(HVR) mode...
  • Page 52 enter and leave, when the moving object meet preset warning area rules, alarm will be triggered. � � � � Rules Rules Rules Rules click setting setting setting setting, enter rule setting page, right click mouse, choose add, use mouse to fix two or more point, and then connect them to form a line or a irregular region, after that a box of prohibited direction options will come out, choose one of them, right click mouse, click Yes, return to previous page, click Yes, alarm rules setting is finished.
  • Page 53 previous page, click Yes, alarm rule setting if finished. Pic 4.14 rule setting - items care Video Video diagnosis diagnosis diagnosis: : : : Video Video diagnosis � Sensitivity Sensitivity Sensitivity Sensitivity , base on different requirement, there are 3 options in the drop-down box type: there are 8 kinds of detection type: Brightness anomaly detection 、...
  • Page 54: System

    example example For example example: enable video analysis function, algorithm rules is PEA PEA, the alert way in the rule is Cordon Cordon Cordon Cordon, prohibited direction is bidirectional, when a moving object across this warning line, alarm is triggered, see below pic4.16 Pic 4.16 the alarm image regarding one of the video analysis Video Teaching http://v.youku.com/v_show/id_XNDY5Mjc0OTcy.html...
  • Page 55 4.4.1 4.4.1 General General 4.4.1 4.4.1 General General Picture 4.17 General setup 【System time】Set the system data and time. 【Date format】Choose the data format: YMD, MDY, DMY. 【Date Separator】Choose list separator of the data format. 【Time Format】Choose time format: 24-hour or 12-hour. 【Language】support 29 language at present: Arabic,Czech,English,Finnish,Greek,Indonesian,Italian,,Japanese,Portuguese,Russian,Thai,T-Chin...
  • Page 56: Encode

    Picture 4.18 DST (week) Picture 4.19 DST (date) 4.4.2 Encode setup 4.4.2 4.4.2 4.4.2 Encode Encode Encode setup setup setup * * * * only only only 6000 6000 series series (other (other products products only only have have analog analog channel) channel)
  • Page 57 Picture 4.20 Encode setup Independent channel code setting 【Channel】Choose the channel number. 【Compression】Standard H.264 main profile. 【Resolution】Resolution type:1080P/720P/960H/D1/ HD1/CIF / QCIF. 【Frame Rate】P:1 frame/s~25 frame/s; N: 1 frame/s~30 frame/s 【Bit Rate Type】 You can choose limited code stream or variable code stream. When you choose the variable code stream there are six image quality options.under the limited code stream,you can choose the code stream manually;...
  • Page 58: Network

    4.4.3 4.4.3 Network Network setup setup 4.4.3 4.4.3 Network Network setup setup Picture4.21 Network 【Net Card】You can choose cable network card or wireless network card. 【DHCP Enable】Obtain IP address automatically(not suggested) Note Note Note Note:DHCP server is preinstalled. 【IP address】Set the IP address. Default: 192.168.1.10. 【Subnet mask】Set the subnet mask code.
  • Page 59: Netsevice

    4.4.4 4.4.4 NetService NetService 4.4.4 4.4.4 NetService NetService Choose the network service option and click the set button to configure the advanced network functions or double click the service button to configure the parameters. Picture 4.22 NetService 【PPPoE setup】 Picture4.23 PPPOE Enable:Reverse■...
  • Page 60 【NTP setup】 Picture 4.24 NTP The NTP server must be installed in the PC. Enable Enable Enable Enable:Reverse■mean choose,setting can become effective. Host Host Host Host computer computer computer computer IP: IP:Input the IP address installed NTP server. Port: Port: Port: Port:Default: 123.
  • Page 61 Picture 4.25 EMAIL SMTP server: SMTP SMTP SMTP server: server: server:Email server address. It could be an IP address or domain name. Domain name can be translated only it is the correct DNS configuration. Port: Port: Port: Port:Email server port number. SSL: SSL: SSL:...
  • Page 62 Picture 4.26 IP FILTER 【DDNS】 Picture 4.27 DDNS setup It is the abbreviation of dynamic domain name server. Local Local Local Local domain domain domain domain name name name name:Provide the domain name registered by DDNS. User User name name User User name name:Provide the account registered by DDNS.
  • Page 63 Picture 4.28 FTP setup 【Enable】Click Enable,then all settings will be available 【Server IP】 IP address for FTP server 【Port】 Domain Port of FTP,default 21 【User Name】User name of FTP 【Password】Password of user 【Anonymous】 :enable anonymous,no need setting user name and password 【Max File Length】Max length for upload files at every packed,default 128M 【Dir Name】...
  • Page 64 [Type] choose "DNS" [Enable]: ■ means it is chosen [Sever IP]: IP address of DDNS server [Port]: Port No. of device, related DDNS server listen port [User name] the user name that device can log in DDNS server [Password] the password related to the user name. [Refresh cycle]:Time interval between device and DDNS when chynchronously.
  • Page 65 Picture 4.31 Wireless Config 【Enable】Choose Enable to make all settings available 【Type】Dial type,default AUTO 【Wireless AP】3G access point 【Dial Number】3G Dial Number 【User Name】User name of 3G 【Password】Password of dial user 【IP Address】IP address,got from dial Note Note Note Note:parts parts parts parts of of of of A A A A series...
  • Page 66 it by mobile 【UPNP】 UPNP protocol is to realize auto port forwarding on router, precondition of using this function is to make sure the UPNP function of router is enabled. Picture 4.33 UPNP 【Enable】Choose Enable to make sure all UPNP settings available 【HTTP】Route will automatically distribute HTTP port for the device,when IE viewing,it need this port 【TCP】Router will automatically distribute TCP port for the device,when monitoring via CMS,it need...
  • Page 67 Pic 4.34 WIFI configure 【Search】 :click【search】to search all the available wireless device in current range. 【enable】 :tick it to enable firstly, then go for further setting. 【auto obtain IP address】 :tick it to enable, device will auto obtain a WIFI IP. 【SSID】...
  • Page 68: Gui Display

    4.4.5 4.4.5 Display Display 4.4.5 4.4.5 GUI GUI Display Display Configure the video output parameters including the front output mode and encode output mode. Front output:In the local preview mode include: channel title, time display, channel display, record status, alarm status, transparency and region cover. Encode output:In the network surveillance and video file mode include: channel title, time display, channel display, record status, alarm status, transparency and region cover.
  • Page 69: Ptz/Rs485

    Pic 4.36 output mode 【Channel Title】Click the channel name modify button and enter the channel name menu. Modify the channel name. The 16 Chinese characters and 25 letters are supportive. 【 Time Display 】 means the selective state. Display the system data and time in the surveillance window.
  • Page 70 Pic 4.37 PTZ configure 【Channel】Choose the dome camera input channel. 【Protocol】Choose the corresponding dome protocol. (PELCOD as an example) 【 Address 】 Set as the corresponding dome address. Default: 1. ( Note : The address must be consistent with the dome address.) 【Baudrate】...
  • Page 71: Rs232

    4.38 RS485 device 【Protocol】choose related protocol of brand model( for example: DaHua); 【Address】set with corresponding address, default is 1; 【Baud rate】choose bard rate that related device use, default is 115200; 【Data bits】including 5-8 options,default is 8; 【Stop bits】including 2 options, default is 1; 【Parity】Include odd check, even check, sign check, blank check.
  • Page 72: Tour

    Pic 4.39 serial port setting 【Serial Port Function】Common serial port is used to debug and update program or set up specific serial port. 【Baud rate】Choose the corresponding baud rate length. 【Data bits】Include 5-8 options. 【Stop bits】Include 2 options. 【Parity】Include odd, even, mark, space, default is none. 4.4.8 4.4.8 4.4.8...
  • Page 73: Spot Set

    Pic 4.40 tour configure 【interval】Set the patrol switch interval. The set range is 5-120 seconds. 【alarm tour】set the interval to shift alarm tour, range is 5-120 seconds, choose return when alarm ends, when alarm link to tour, system will auto shift to six-view after alarm finished. Remark Remark Remark...
  • Page 74 Channel manage page under all analog(DVR) mode Digital Digital channel: channel: Digital Digital channel: channel: 第 77页...
  • Page 75 Single link page of digital channel Multi-linkage page of Digital channel Pic 4.43 digital channel interface 【Channel】select channel title 【Enable】Open digital channel, tick enable, then can do related settings 【Time Synchronization】Tick it means the time of this channel and device is the same. 【Connection Mode】can be singe connect or multi-ink, multi-link modes can connect to several devices, device will be tour displayed one by one, tour interval can be set, no less then 10s;...
  • Page 76 Pic 4.44 remote channel configure page 【Configure Name】device is with default configure title, user can revise it if necessary; 【Device Type】3 types: IPC、DVR、HVR,user can choose as what you like, default is IPC; 【Protocol】Default is TCP 【 Remote channel 】 User can input remote channel title from the device that you want to connect remotely 【Stream】Default is main stream, do not support extra-stream at present;...
  • Page 77 Channel Channel Status Status Status: : : : Channel Channel Status channel status is to show the status of all the digital channel When there is what existing, status including Max Resolution, This Resolution, Connection Status. For example: The channel status for 4+2 mode is as below: When a channel is added with device but it is not enable, you will see as below: Channel status interface under full digital(NVR) mode (One of the channel without device) 第...
  • Page 78 Remark: when current resolution resolution is is is is over over resolution that channel supported, then Remark: Remark: Remark: when when when the the current current current resolution resolution over over the the max max resolution resolution resolution that that that the the channel channel...
  • Page 79: Advanced

    Advanced Advanced 4.5 Advanced Advanced Manage tools menu including: HDD manage, account manage, online user, output adjust, auto maintain, upgrade. 4.5.1 4.5.1 4.5.1 4.5.1 HDD HDD Manage Manage Manage Manage Configure and manage the hard disk. The menu displays current hard disk information: hard disk number, input port, type, status and overall capability.
  • Page 80 2. There is no limit in the user and user group. You can add or delete the user group according to user definition. The factory setup include: user\admin. You can set the team as you wish. The user can appoint the purview in the group. 3.
  • Page 81 Pic 4.48 modify password 【Add user】Add a user in the group and set the user purview. Enter the menu interface and input the user name and password. Choose the team and choose whether cover using the user. Cover using means that the account can be used by multiple users at the same time. Once choose the team the user purview is the subclass of the team.
  • Page 82: Online User

    Pic 4.50 add group 【Delete User】Delete the current user. Choose the user and click delete user button. 【Delete Group】Delete the current group. Choose the group and click delete group button. Pic 4.51 Delete Group 4.5.3 Online user 4.5.3 4.5.3 4.5.3 Online Online Online user user...
  • Page 83: Output Adjust

    4.5.4 4.5.4 adjust adjust 4.5.4 4.5.4 TV TV adjust adjust Refer to chapter 3.5.7 . 4.5.5 4.5.5 4.5.5 4.5.5 Auto Auto Auto Auto Maintain Maintain Maintain Maintain The user can set the time to auto reboot and auto delete file. Picture 4.39 Auto maintain 4.5.6 4.5.6...
  • Page 84: Upgrade

    4.5.7 4.5.7 Upgrade Upgrade 4.5.7 4.5.7 Upgrade Upgrade Upgrade Pic 4.55 【Upgrade】choose choose choose interface. interface. choose USB USB interface. interface. 【Upgrade file】choose choose upgrade file. choose choose the the upgrade upgrade upgrade file. file. file. 4.5.8 4.5.8 4.5.8 4.5.8 Device Device Device Device Info...
  • Page 85: Info

    4.57 Import / Export interface Info Info 4.6 Info Info Display the hard disk information, including HDD info, code stream statistic, log info, version info 4.6.1 info 4.6.1 4.6.1 4.6.1 HDD HDD info info info Display the hard disk state: hard disk type, overall capability, residual capability, the recording time and so on.
  • Page 86: Bps

    Pic 4.58 HDD info Tips Tips Tips Tips:○ means that the hard disk is normal. X means that the hard disk is broken-down.- means that there is no hard disk. If the user need to change the damaged hard disk, you must shut down the DVR and take up all the damaged hard disks,then install a new one.
  • Page 87: Version

    Pic: 4.60 Log information 4.6.4 4.6.4 4.6.4 4.6.4 Version Version Version Version Display the basic information such as hardware information, software version, issue date, serial number , NAT status and so on. Pic 4.61 version information Shut down system 4.7 Shut Shut Shut down down...
  • Page 88: Xm Cloud Basic Operation

    Chapter Chapter Chapter Chapter 5: 5: 5: 5: Cloud Cloud Cloud Cloud Technology Technology Technology Technology Basic Basic Basic Basic Operation Operation Operation Operation Cloud Cloud Cloud Cloud technology technology technology technology monitor monitor monitor monitor Cloud technology make the device one step on net, greatly bring convenience for customer to monitor via wide area network, this technology is using the serial no to visit device.
  • Page 89 � � � � Log in in in in by by user user user user Customer use their registered user name and password to log in, will see below interface Pic 5.3 cloud technology operation interface Device Device manage manage Device Device manage manage...
  • Page 90 Pic 5.4 device manage interface Pic 5.5 add interface at device manage *Remark *Remark *Remark *Remark:in in in in pic pic 5.5, 5.5, 5.5, 5.5, the the user user user user name name name name means means means means the the user user user...
  • Page 91 Pic 5.6 monitor page - log in by user *Remark *Remark icon icon icon of of of of“ “ “ “ ” ” ” ” means means means offline, offline, device device connect connect connect to to to to server server server successfully.
  • Page 92 Pic 5.7 interface of log in by device Input the serial number of device and the verify code to monitor and control the device directly. Pic: 5.8 monitor page - log in by device 第 95页...
  • Page 93: Faq And Maintenance

    6 6 6 6 FAQ maintenance maintenance FAQ and and maintenance maintenance 6 6 6 6 .1 .1 .1 .1 FAQ If the problems are not listed, please contact the local service or call the HQ service. We are willing to offer the service.
  • Page 94 4、 There There There There are are no no video video video video outputs outputs outputs outputs in in in in single single single single channel, channel, channel, channel, multiple multiple multiple multiple channels channels channels channels and and all all channels.
  • Page 95 Possible reasons are as followed: It is not an active tone arm. It is not an active sound box. The audio lines are damaged. The hardware of the DVR is damaged. There There There is is is is audio audio audio signal signal...
  • Page 96 The motion detect area set is not correct. The sensitivity is too low. Limited by some hardware edition. I I I I can login login web or or or or CMS. CMS. CMS. 13、 can not not login login via via web CMS.
  • Page 97 The rewritable machine and the hard disk are shared the same data lines. The data is too much. Please stop recording and backup. The data exceeds the backup storage. The backup equipment is not compatible. The backup equipment is damaged. keyboard keyboard control...
  • Page 98 21、 The storage storage storage storage time time time time is is is is not not enough. enough. enough. enough. Possible reasons are as followed: Front vidicon quality is bad. The lens is too dirty. The vidicon is in backlighting installation. The hard disk capability is not enough.
  • Page 99: Maintenance

    snapshot snapshot snapshot at at at at alarm alarm alarm function function enable, enable, catch catch picture picture 26、 The snapshot alarm function function was was enable, enable, why why not not catch catch picture picture Possible reasons are as followed: 1 HDD manage without partition for snapshot.
  • Page 100: Appendix 1.Remote Controller Operation

    Appendix Appendix 1.Remote 1.Remote controller controller operation operation Appendix Appendix 1.Remote 1.Remote controller controller operation operation Serial Serial Serial Serial Name Name Function Function Name Name Function Function number number number number 1 1 1 1 POWER Power ON/OFF MENU Access main menu 2 2 2 2 Exit operation or enter upper menu...
  • Page 101: Appendix 2.Mouse Operation

    Digital input Corresponding; 0~9 10+ Channel is magnified in full screen under preview state Short cut Switching of 1/4/8/9/16/24/32Preview mode Alarm reset ALARM Clear alarm CLEAR Device Selection Mute allowed/prohibited Appendix 2.Mouse operation Appendix Appendix Appendix 2.Mouse 2.Mouse 2.Mouse operation operation operation * Take...
  • Page 102: Appendix 3.Hard Disk Capacity Calculation

    Appendix Appendix 3.Hard 3.Hard disk disk capability capability calculation calculation Appendix Appendix 3.Hard 3.Hard disk disk capability capability calculation calculation Make sure the hard disk installed to the DVR for the first time. Pay attention to the IDE hard disk lines connection.

This manual is also suitable for:

Ahd-gd series

Table of Contents