Dobrý den. Potřebuji poradit. Jak Mám nastavit koncovou polohu pro zavírání a koncovou polohu pro otvírání. Žádné automatické zavírání zakazník nepotřebuje ani rychlost postačí pomalu ale chce jenom polohu zavřeno a polohu otevřeno. Děkuji
1 comments:
Mr. Anderson
February 18, 2025
The end positions for closing and opening on the HATO 400Y are set using the spring limit switches. These switches ensure that the gate stops at the correct position when fully opened or closed. Proper alignment of the limit switch, block, and rack is necessary to meet the required positioning. Ensure that the installation follows the manual's instructions for correct setup and adjustment.
OUTLINE 1. Important safety information………………………3 2. Main technical parameters ………………………3 3. Installation …………………………………………3 4. Connecting …………………………………………7 5. Control ……………………………………………10 6. Check ……………………………………………14 7. Maintenance………………………………………14 8.Troubleshooting …………………………………15...
Page 3
-20ºC~+50ºC 3. Installation The HATO 400 Y rack-driven gate operator operates by forcing a drive rack past a drive gear. The entire configuration is shown in Fig.1. The gate operator must be installed on the inside of the gate. Gate preparation Be sure the gate is properly installed and slides smoothly before installing the DKC400Y sliding gate operator.
Fig.1 Concrete pad The base unit of the gate operator requires a concrete pad in order to maintain proper stability. The concrete pad should be approximately 300mm x 200mm x 200mm deep in order to provide for adequate operation. Anchors You can use the anchors, bolts, washers and nuts that are provided with the operator.
Page 5
Fix the three nuts (in the same package with rack) on the rack element. Lay the first piece of rack on the gear and weld the first nut on the gate. Move the gate manually, checking if the rack is resting on the gear, and weld the second and third nut. ...
Page 6
Rack Fig.5 CONFORMITY DECLARATION: Motor Hato 400Y meets the requirements set out in the following provisions: It’s in accordance with Machine Directive 2006/42/WE and following modify. It’s in accordance with the following directive CE: Electromagnetic compatibility Directive EMC 2014/30/UE and following modify.
Page 7
Controller of Gate Drives for 230Vac 500W Motors USER’S MANUAL...
Page 8
SOFTWARE MARKING NOTES 1.2.0-C-NO HEL11C 11:8.2.2/6.1.0 Before the installation and first use of the controller read the manual carefully and keep it for future reference. According to the Machinery Directive 2006/42/CE, the product must not be put into service until the final machinery into which it is to be incorporated or of which it is to be a subassembly has been declared in conformity with the provisions of directives and relevant regulations which the final machinery must comply with.
Version : HEL11C • – cooperates with Hato’s transmitters operating at a 433.92 MHz frequency and compatible with Keeloq protocol. • – with encoder input • – lamp control by relay Table of contents: OUTLINE ......................................2 Anchors ......................................4 1.
1. Application and functionality of HEL11C The controller is designed for gate drives with 230Vac motors. A perfect choice for continuous operation, the controller can be used in community car parks, private homes and corporate compounds. Applied Microchip rolling code technology prevents from not authorized entrance.
command after powering up is “open”. Press the SBS or programmed transmitter button. If drive works in closing 2.4 Step-By-Step pushbutton connection direction stop the motor, switch off the power supply and Connect the SBS pushbutton using 2x 0,5mm wire which switch motor’s leads connected to the inputs OPEN(10) parameters are according to regulations: CEI 20-22;...
necessitates photocells to ensure user safety (to prevent 4. Transmitters deleting and gate from closing when an obstacle is within its range!). in addition, the photocells will reduce the opening time. The programming controller will detect the passage of a vehicle and will close the gate after 5 seconds.
Page 13
Tab.1.1. Autoclose time setting (e.g.) 1. Press the LEARN button. The LED will light up. Release the button. LEAR LEAR 2. Then, by pressing the same button you can set the delay time. One keystroke corresponds to 15 seconds, (e.g. 4 keystrokes mean 1 minute; the LED dims at each keystroke).
Need help?
Do you have a question about the 400Y and is the answer not in the manual?
Questions and answers
Dobrý den. Potřebuji poradit. Jak Mám nastavit koncovou polohu pro zavírání a koncovou polohu pro otvírání. Žádné automatické zavírání zakazník nepotřebuje ani rychlost postačí pomalu ale chce jenom polohu zavřeno a polohu otevřeno. Děkuji
The end positions for closing and opening on the HATO 400Y are set using the spring limit switches. These switches ensure that the gate stops at the correct position when fully opened or closed. Proper alignment of the limit switch, block, and rack is necessary to meet the required positioning. Ensure that the installation follows the manual's instructions for correct setup and adjustment.