Resetting the system

Plug your Hot Water Dispenser into the mains outlet and
1 8
switch on at the socket.
The Dispense Button (5) will flash and the 'Dispense Icon'
21
(13) will appear on the screen.
Place an empty vessel, such as a measuring jug or
22
saucepan underneath the Dispense Nozzles (6).
Press the Dispense Button to reset the system. Any
23
remaining water will be dispensed from the system into
the vessel below. This takes approximately 35 seconds. It
is now ready for use.
Before using your Hot Water Dispenser for the first time,
or after it has been unplugged from the mains.You must
perform the following steps to reset your Hot Water
Dispensers' heating chamber.
YourHotWaterDispenserwillnotfunction
ifthesystemhasnotbeenreset.
12
LCD Display Glossary
Belowaresomeoftheiconsthatmayhighlightduring
use,andtheirmeaning.Refertotheinstructionbookfor
moreinformationonthesettings.
Reset
2 4
After the Hot Water Dispenser has been switched on, the
Dispense Icon (13) and the Dispense Button (5) are flashing.
The system needs to be reset before use. Follow the
instructions under 'Resetting the System'.
Auto Dispense
2 5
The Auto Dispense (14) Icon is lit after heating.
Volumes between 150-600ml will be automatically dispensed
unless deselected by pressing the Dispense Button (5).
Volumes above 600ml cannot automatically be dispensed.
Water Still to Dispense
After heating or being woken from standby, the Dispense
Icon (13) is flashing.
There is still water remaining in the heating chamber. Either
reheat or dispense water before next use.
Water Tank
2 7
The Water Tank Icon (12) is flashing.
The Water Tank (7) is either empty or not properly fitted.
Fill the Water Tank and ensure the Water Tank is securley
fitted to the Main Unit (23).
Heat Icon
2 8
In manual dispense mode, after heating the water the Heat
Icon (11) remains lit.
The Boil Icon remains lit while the water is within 5°C
of the desired temperature. If the water drops more than
5°C then the icon will extinguish, the Start Stop Button will
illuminate and the water can be reheated by pressing the
Start/Stop Button (1).
Descale
2 9
The Descale Icon (16) is lit.
Your Hot water Dispenser needs descaling. Follow the
instructions under 'Descaling' to descale the heating
chamber.