Mitsubishi Electric MSC-A07YV-E1 Service Manual page 25

Wireless type
Table of Contents

Advertisement

TEST POINT DIAGRAM AND VOLTAGE
MSC-A07YV -
E1
MSC-A09YV -
E1
MSC-A12YV -
E1
Indoor electronic control P.C. board
Varistor
(NR11)
--
{
12V DC
+
Power monitor,
receiver P.C. board
CN302
Fuse 250V AC 3.15A
+
5V DC
25
}
Indoor fan motor
230 V AC
}
Power supply input
230 V AC
R132
Indoor coil
thermistor (RT12)
Room temperature
thermistor (RT11)
}
Timer short mode
point JPG, JPS
(Refer to page 17.)
Emergency
operation switch
SW2
(Refer to page 18.)
1 sets the Auto restart
function ON/ OFF.
--
2 switches over MU&MUX type/
MUH & MXZ type.
Indoor coil thermistor (RT12)
Room temperature thermistor (RT11)
40
30
20
10
0
0
10 20 30 40 50 60
Temperature
(; ; )

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc-a12yv-e1Msc-a09yv-e1Msc-a07yvMsc-a09yvMsc-a12yv