Horizontal Scanning; Vertical Scanning; Power Input Connection; Power Management - Philips 150S8FB/00 Service Manual

Lcd color monitor
Table of Contents

Advertisement

3.4 Horizontal scanning

Sync polarity
Scanning frequency

3.5 Vertical scanning

Sync polarity
Scanning frequency

3.6 Power input connection

Power cord length
Power cord type

3.7 Power management

The monitor must comply with the Microsoft on Now specification, with two power management states, as defined
by the VESA DPMS document. The monitor must appropriately display the DPMS state.
Mode
Power-On
Off
DC Power Off

3.8 Display identification

In accordance with VESA Display Channel Standard Ver.1.3 and DDC 2B capability
3.9 USB support: NA

4. Visual characteristics

4.1 Test conditions

Unless otherwise specified, this specification is defined under the following conditions.
(1) Input signal : As defined in 3.3, 1024 x 768
non-interlaced mode (48K/60Hz), signal
sources must have 75 ohm output impedance.
(2) Luminance setting
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 25 ± 5 °C

4.2 Brightness

>=200 nits (at panel color temperature, at center of the screen, set contrast and brightness at maximum.)

4.3 Image size

Actual display size
: Positive or Negative
: 30 – 63 K Hz
: Positive or Negative
: 56 - 76 Hz
: 1.8 M
: 3 leads power cord with protective earth plug.
HSYNC VSYNC
Video
On
On
active
Off
Off
blanked
N/A
: controls to be set to 200 nits with
full screen 100 % duty cycle white signal
304.128 x 228.096 mm
Power-cons.
Indication
< 23 W
Green LED
< 1 W
Amber LED
< 1 W
LED Off
HUDSON 8
97
Rec. time
--
< 3 s

Advertisement

Table of Contents
loading

This manual is also suitable for:

150s8fb/93150s8fs/00150s8fb/78150s8fbj/78150s8fs/78

Table of Contents