Panasonic DMR-EH57EC Service Manual page 23

Table of Contents

Advertisement

Mode name
HDD
READ
VERIFY
Measure of access time in READ VERIFY
Inspection
MODE of HDD.
HDD Spin-up time
The accumulation value of the Spin-up time of
HDD is displayed.
Item
Description
DMR-EH57EC / DMR-EH57EP / DMR-EH57EE / DMR-EH575EG
FL display
At start
The [*] sign is added every 20
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection
(The unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.
)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position
at
$
is
space
excluding those.
##:
Number
of
data
of
100msec. and less than 270msec.
When it is over 100, [99] is
displayed.
When the number is less than 5, we
judge it normal.
Spin-up time of HDD is displayed.
(The unit of display is hour.)
23
Key operation
(Remote controller key)
Press [3] [2] in service mode.
* When canceling the inspection
mode while executing, do "forced
power-off".
Method:
Press [POWER] key more than 10
seconds.
when
over
Press [3] [3] in service mode.