Troubleshooting
Problem
The unit does not work. L When the indicators do not light, the AC adaptor is not
While talking using the
handset, sound cuts in
and out.
The STATUS indicator
continues to light
amber for a while.
Cause/solution
connected properly. Check the connections.
L When the indicators do not light green, move the unit
closer to the base unit.
L Registration may have been canceled.
Deregister the unit, then re-register.
Deregister:
1
Unplug the AC adaptor, then press and hold
{PROGRAM}.
2
While pressing and holding {PROGRAM},
re-connect the AC adaptor.
3
Keep pressing and holding {PROGRAM} for about
10 seconds until the STATUS indicator flashes
amber. Then release {PROGRAM}.
Re-register:
1
Range extender: Unplug the AC adaptor.
2
Base unit: Press and hold {LOCATOR} for about
5 seconds until the registration tone sounds.
– The next step must be completed within 90
seconds.
3
Range extender: Connect the AC adaptor, then
wait until the STATUS indicator lights green.
4
Base unit: To stop the registration tone, press
{LOCATOR}.
L The handset is out of range. Move the handset closer
to this unit.
L {PROGRAM} was pressed. The unit is in
programming mode. To exit, press {PROGRAM}
again. Do not press {PROGRAM}, except when
deregistering the unit.