Download Print this page

XDISC ACTIVESOL LIGHT User Manual

Flexible photovoltaic modules

Advertisement

Quick Links

ACTIVESOL LIGHT & ACTIVESOL ULTRA
This manual includes information regarding safety and guidelines regarding the ACTIVESOL flexible photovoltaic
modules system manufactured by XDISC S.A.
It is necessary to get acquainted with this manual prior to the installation, operation and maintenance of the modules.
Non-compliance with the manual entries may result in the destruction of property, body injuries or, in extreme cases,
in death.
LIMITED RESPONSIBILITY
XDISC S.A. does not have any say in terms of the method of installation, operation and use of the ACTIVESOL flexible
modules. Due to the above, XDISC is not responsible for any losses, damage and costs resulting from incorrect
installation, operation and use of the modules.
INTENDED USE
The ACTIVESOL LIGHT & ULTRA are flexible photovoltaic modules for creating autonomous (off-grid) power supply
systems.
GENERAL RECOMMENDATI ONS
All electrical systems must be executed according to the current legal regulations
It is necessary to verify the technical condition of the module prior to installation
The modules should be installed by a qualified personnel
It is forbidden to connect power receivers directly to the photovoltaic module
The total voltage of the system, the basis of which consists of the ACTIVESOL LIGHT & ULTRA modules, should
not exceed 1,000 VDC.
In real conditions, the photovoltaic modules may generate more current or more voltage than in the standard
testing conditions. Due to safety reasons, during the system designing, it is necessary to consider increased
rated values of the ACTIVESOL LIGHT & ULTRA modules; short-circuit current (Isc) and open circuit voltage
(Uoc), by multiplying them by the 1.25 coefficient.
USER MANUAL
FLEXIBLE PHOTOVOLTAIC MODULES
IFU ACTIVESOL FLEX en 10 17 V.3.

Advertisement

loading

Summary of Contents for XDISC ACTIVESOL LIGHT

  • Page 1 LIMITED RESPONSIBILITY XDISC S.A. does not have any say in terms of the method of installation, operation and use of the ACTIVESOL flexible modules. Due to the above, XDISC is not responsible for any losses, damage and costs resulting from incorrect installation, operation and use of the modules.
  • Page 2 risk of electrical shock do not install the modules during the installation and install and disassemble in dry near sources of heat and disassembly of the module, cover conditions combustible materials the module with material which keeps the light out do not load the modules with use insulated tools do not stand and walk on the...
  • Page 3: Electrical Connection

    The parallel connection causes a circuit increase proportionate to the number of modules. It is recommended to connect a maximum of 2 rows of ACTIVESOL LIGHT & ULTRA modules in a parallel circuit. In case of connecting more rows, it is necessary to provide an additional security at each row (when the maximum reverse current exceeds the acceptable circuit breaker load, the serial rows must be secured before they are connected to other rows).
  • Page 4 The photovoltaic module and battery must be connected to the charging controller. MAINTENANCE The ACTIVESOL LIGHT & ULTRA modules do not require special maintenance. The module must be cleaned on a regular basis and verified periodically in terms of the mechanical and electrical connections. It is also necessary to control the system’s performance by verifying the module’s electrical parameters on a regular basis.

This manual is also suitable for: