Morris 59151 User Manual

Multi-functional led light meter

Advertisement

Quick Links

Morris Products Inc

Table of Contents

TABLE OF CONTENTS ...................................................................................... 2
INTRODUCTION ................................................................................................. 4
OPEN-PACKAGE INSPECTION ........................................................................ 4
SAFETY INFORMATION ................................................................................... 5
1 INTRODUCTION .............................................................................................. 9
1.1
P
RODUCT DESCRIPTION
1.2
O
UTSTANDING FEATURES OF MULTI
1.3
1.3.1
Plan view ............................................................................................................................... 10
1.3.2
LCD display interface ........................................................................................................... 21
2 MEASUREMENT METHODS ....................................................................... 22
2.1
2.2
A
CTION PRINCIPLES
Cat# 59151
Multi-functional LED
Light Meter
USER MANUAL
www.morrisproducts.com
Cat# 59151 Multi Function LED Light Meter
........................................................... E
-
FUNCTION
........................................................................................ 10
................................................................................................ 22
................................................................. E
1-888-777-66788
! B
RROR
LED
................................................ 9
LIGHT METER
! B
RROR
OOKMARK NOT DEFINED
OOKMARK NOT DEFINED
.
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 59151 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Morris 59151

  • Page 1: Table Of Contents

    Multi-functional LED Light Meter USER MANUAL Morris Products Inc www.morrisproducts.com 1-888-777-66788 Cat# 59151 Multi Function LED Light Meter Table of Contents TABLE OF CONTENTS ..................2 INTRODUCTION ....................4 LIMITED WARRANTY, RIGHTS AND RESPONSIBILITIES ......4 OPEN-PACKAGE INSPECTION ................ 4 SAFETY INFORMATION ...................
  • Page 2: Introduction

    Open-package inspection Upon reception of the light meter, inspect it to ensure no damage during shipping. If the user finds obvious damage or malfunction in operation, please contact MORRIS. Included in Carton: Light Meter...
  • Page 3: Safety Information

    User should observe the following notices to guarantee safe operation and obtain optimum performance. 1: Preliminary check Before initial use, please check if the light meter operates normally and if it is damaged during storage and transportation. In case of any damage please contact MORRIS.
  • Page 4 Mechanical Dust vibration Cat# 59151 Multi Function LED Light Meter 3: Use Notice 1: The operation temperature range for the light meter is -10-50℃ (14-122°F). 2: In order to avoid damage, especially falling accidents, handling and use should be avoided during severe mechanical vibration.
  • Page 5: Introduction

    (The machine will be powered off automatically keys are not operated for more than 10 minutes)  Compact design, durable, and portable. Cat# 59151 Multi Function LED Light Meter 1.2 Name and Function of Components 1.21Plan view ① Opto-sensor protection cover ②...
  • Page 6: Measurement Methods

    ⑧ Prompt for peak value measurement mode ⑨ Prompt for low battery ⑩ Prompt for relative value measurement mode 11.12 Prompt for max and min values inquiry Cat# 59151 Multi Function LED Light Meter Measurement Methods 1.3 Notices Prior to Measurement Warning...
  • Page 7: Concepts Of Illuminance Scales

    2-1. Press and hold the 59151 power key ④ for a short time to power on the light meter. The LCD screen will illuminate(about 5 seconds)with the buzzer beeping twice and “AUTO” will appear on the middle of LCD display.
  • Page 8 Cat# 59151 Multi Function LED Light Meter Press and hold the REL/PEAK key ⑧ of the 59151 for a short time, “REL” will appear on the top left position of the LCD interface, indicating the activation of the relative value measurement mode. Press and hold the key ⑧...
  • Page 9: Specific Application

    Cat# 59151 Multi Function LED Light Meter 2 Specific Applications 2.1 Application of manual switchover of range measurement mode  Press and hold the RAN key (range manual switchover key) for a short time, “MANU” will appear on the top left position of the LCD interface, and the meter will enter the manual switchover measurement mode (as shown in figure 3-1-1) ...
  • Page 10: Application Of Maximum/Minimum Value Inquiry Mode

    Cat# 59151 Multi Function LED Light Meter 2.2 Relative/peak value measurement mode applications  Press and hold REL/PEAK key for a short time (composite key for relative/peak value measurement), “REL” will appear on the top left of the LCD screen (as shown in figure 3-1-2A), and the device will enter the relative value measurement mode;...
  • Page 11: Application Of Data Hold And Zero Calibration Mode

    Cat# 59151 Multi Function LED Light Meter Tips In non-zero calibration mode, press and hold “MAX/MIN” key for a short time to use the max/min value inquiry functions; 2.4 Application of data hold and zero calibration mode  Press and hold “HOLD/ZERO” key for a short time, “HOLD” will appear on the top left of the LCD screen (as shown in 3-1-4A), then the device will enter the data hold mode ...
  • Page 12: Technical Data

    Cat# 59151 Multi Function LED Light Meter 3 Technical Data  Temperature range: Operation:-10~50 C, max 80 % HR(Non-Condensed) Storage:-10~50 C,max 80 % HR (Non-Condensed) (removing batteries)  Sampling rate: ≥2 times/s。  Display: 3½ digits, max reading of 1999, with analog bar display;...
  • Page 13: Maintenance And Service

    Cat# 59151 Multi Function LED Light Meter 4 Maintenance and Service 4.1 Service Notice When the meter seemingly fails during operation, following steps should be followed to check the fault problem: 1: Check batteries. If “ ” appears on the LCD display, batteries should be replaced.
  • Page 14: Calibration Interval

    Cat# 59151 Multi Function LED Light Meter Notice 1: The light meter should be turned off before replacing batteries. 2: Use batteries specified in technical data only. 3: If the meter is not to be used for a long time, remove the batteries.
  • Page 15 Cat# 59151 Multi Function LED Light Meter Office: Iluminance Locations (Lux) 2000~1500 Design office, clerk's office 1500~750 Hall information channel (daytime), parlor, drawing office, punching, typing Calculator room, conference room, printing room, switchboard room, control 750~300 room, reception room, recreation room, restaurant...
  • Page 16 Cat# 59151 Multi Function LED Light Meter Hotel, restaurant, recreation ground: Iluminance Locations (Lux) 1500~750 Counter 750~300 Halfway, banquet hall, business room, parking lot, kitchen 300~150 Restaurant, toilet, a large Japanese-style room Recreation room, corridor, stairways, guest room, bathroom, accent lighting for...

Table of Contents