2.3. Monitor microprocessor software version upgrade
Create the USB memory for monitor microprocessor software version upgrade in the same manner as explained in the "Main software version
upgrade".
Copy the file SFIAT925TBxxx.USB and SFIAESUBxxx.BIN (named temporarily) for monitor microprocessor software version upgrade to the USB
memory.
2.3.1 How to upgrade the software
1. Plug AC cord and turn on the TV.
2. After picture displayed, touch the power key for 5seconds.
NOTE: Picture will disappear when you touch the power key, but keep touching it.
3. When the center icon LED blinks, release your finger from the power key.
4. Next, touch the "POWER" key with the "CH (
5. When the center icon LED turns on, release your finger from the keys.
CAUTION: •
The moment this operation is done, the upgrading of the monitor microprocessor software starts. While the upgrade is ongoing, never
power off the unit. Otherwise the upgrade will fail and the system may be serious damaged beyond recovery (inability to start).
After the monitor microprocessor software is upgraded, also perform the 'Industry Init'.
6. After the unit startup, the upgrade starts. The power led will blink continuously. Also, an upgrade screen will be shown during a minor upgrade.
7. If the upgrade fails, power led will stop blinking. Also, the upgrade failure screen will be shown if upgrade screen was shown at 5.
NOTE: In the event of a transient failure, upgrade will be automatically retried up to three times. If the process repeatedly fails, hardware may be the
cause.
8. The upgrade success screen will be shown if upgrade screen was shown at 5.
9. Unplug the AC cord and remove the USB Memory for version upgrade.
10.Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the mon-
itor microprocessor software version information and panel size information.
)" key touching.
Software Update
MAIN
SUB MICOM
PANEL EEPROM
3D IR MICOM
MAIN Version
SUB MICOM Version
PANEL EEPROM
3D IR MICOM Version
Software Update
UPGRADE FAILURE
MAIN
SUB MICOM
SAME VERSION
PANEL EEPROM
3D IR MICOM
MAIN Version
SUB MICOM Version
PANEL EEPROM
3D IR MICOM Version
Software Update
UPGRADE SUCCESS
MAIN
SUB MICOM
PANEL EEPROM
3D IR MICOM
MAIN Version
SUB MICOM Version
PANEL EEPROM
3D IR MICOM Version
3 – 2
60LE925
NO DATA
50%
NO DATA
OK
0.820
1.00
60LE925
NO DATA
NO DATA
OK
1.00
60LE925
NO DATA
100%
NO DATA
OK
0.820
1.00