SBX-32
SINGLE BUS
CONTROL PANEL
OPERATOR'S MANUAL
SIGMA ELECTRONICS, INC.
P.O. Box 448
1027 COMMERCIAL AVENUE
EAST PETERSBURG, PA 17520
(717) 569-2681

Advertisement

loading
Need help?

Need help?

Do you have a question about the SBX-32 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sigma SBX-32

  • Page 1 SBX-32 SINGLE BUS CONTROL PANEL OPERATOR’S MANUAL SIGMA ELECTRONICS, INC. P.O. Box 448 1027 COMMERCIAL AVENUE EAST PETERSBURG, PA 17520 (717) 569-2681...
  • Page 2 Green numeric LED’s display the current input levels. If any level is in a preset condition, the respective display window will flash. The SBX-32 is an intelligent panel in that it will automatically configure itself to the size of the system for which the SCI-ADX is configured. See separate information on the SCI-ADX for details of system matrix configuration.
  • Page 3 The SBX-32 will only function with valid source data received from the SCI-ADX system control interface module. If SCI-ADX is set for 16 sources, the only SOURCE switches that are functional are 1-16.
  • Page 4 The COMM panel address table is shown below. AUTOTAKE S1-7 the AUTOTAKE function of the SBX-32. When the AUTOTAKE function is enabled, the TAKE request will automatically be generated whenever a valid input is selected.
  • Page 5 SBX-32 PANEL ADDRESS (cont.) ADDRESS S1,1 S1,2 S1,3 S1,4 S1,5 S1,6 AUTOTAKE S1,7 DISABLED ENABLED ON [UP] OFF [DOWN] S1 CONFIGURATION (Panel Address 7 and AUTOTAKE disabled shown)
  • Page 6: Output Address

    OUTPUT ADDRESS The SBX-32 is used to control one (1) output in an ADX matrix system. S2 switches 3 through 9 are used to configure which specific output an individual SBX-32 will control. The SBX-32 OUTPUT ADDRESS table below specifies the switch setting necessary to communicate to the SCI-ADX which output is to be controlled.
  • Page 7 SBX-32 OUTPUT ADDRESS (cont.) OUTPUT S2,3 S2,4 S2,5 S2,6 S2,7 S2,8 S2,9 NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing and restoring power.
  • Page 8 SBX-32 OUTPUT ADDRESS (conc.) OUTPUT S2,3 S2,4 S2,5 S2,6 S2,7 S2,8 S2,9 NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing and restoring power.
  • Page 9: Power Supply

    SBX-32 THEORY OF OPERATION SBC-9632 MICROPROCESSOR PCB 1. POWER SUPPLY Power to the remote panel is supplied by a 9-12 VDC wall-pack power supply through J1. Polyswitch RT1 provides fault current protection to the wall pack supply and the remote panel.