AP LifePro50p User Manual And Installation Manual

Air quality mobile
Table of Contents

Advertisement

Quick Links

AIR QUALITY
50P
Jan 2012
MOBILE
USERS' MANUAL AND
INSTALLATION GUIDE
Automatikprodukter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LifePro50p and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AP LifePro50p

  • Page 1 AIR QUALITY Jan 2012 MOBILE USERS' MANUAL AND INSTALLATION GUIDE Automatikprodukter...
  • Page 2 AIR QUALITY Jan 2012 MOBILE Automatikprodukter...
  • Page 3: Table Of Contents

    AIR QUALITY Jan 2012 MOBILE SUMMARY GENERAL ..............................5 IDENTIFICATION OF THE MACHINE ....................5 MARKING OF THE MACHINE ......................6 1.2.1 Opening the door ..........................6 PACKAGING AND TRANSPORT .......................7 PACKAGING ............................7 TRANSPORT ............................7 INSTALLATION OF THE MACHINE ......................8 VENTILATING THE PREMISES ......................9 FILTER UNIT ............................9 METAL PRE-FILTER..........................9 ELECTROSTATIC CELL ........................10...
  • Page 4 AIR QUALITY Jan 2012 MOBILE 8.1.3 MANUAL, TEST, ON-OFF FILTER AND RESET BUTTONS .............29 OPERATION OF THE MACHINE .......................29 FILTERING STATUS .........................30 INFRARED REMOTE CONTROL UNIT .....................30 POWER SUPPLY AND ANTI BLACK-OUT SYSTEM ................30 PURIFICATION ..........................31 SIGNALS ............................31 STATE OF FILTRATION EFFICIENCY ....................31 ELECTRONIC CIRCUIT ALARM SIGNALS ..................32 8.10 ELECTRONIC CIRCUIT ANOMALOUS SIGNALS ................33...
  • Page 5: General

    AIR QUALITY Jan 2012 MOBILE G E N E R A L Air cleaners and Revitalizers 50P, built for the purposes of improving the characteristics of the air in closed environments. There are available two different technologies: Nature System, Basic System. 1 .
  • Page 6: Marking Of The Machine

    AIR QUALITY Jan 2012 MOBILE 1 . 2 M A R K I N G O F T H E M A C H I N E The EC conformity mark is located on the control panel of the machine. 1 .
  • Page 7: Packaging And Transport

    AIR QUALITY Jan 2012 MOBILE P A C K A G I N G A N D T R A N S P O R T 2 . 1 P A C K A G I N G The machine is supplied in a cardboard box internally lined with polystyrene. We recommend keeping all the packaging just in case the machine has to be returned to the manufacturer or the dealer for extraordinary maintenance or repairs.
  • Page 8: Installation Of The Machine

    AIR QUALITY Jan 2012 MOBILE I N S T A L L A T I O N T H E M A C H I N E For a correct function, place the machine so that the air can fulfil the cycle as figured on the picture. The air that comes out of the hinder air diffuser must not find near obstacles which can obstruct to close the cycle of purifying.
  • Page 9: Ventilating The Premises

    AIR QUALITY Jan 2012 MOBILE 3 . 1 V E N T I L A T I N G T H E P R E M I S E S All rooms where people are present carrying out any activity must be fitted with appropriate apparatuses which guarantee adequate reoxygenation of the environment.
  • Page 10: Electrostatic Cell

    AIR QUALITY Jan 2012 MOBILE 3 . 4 E L E C T R O S T A T I C C E L L The electrostatic cell filters the pollutant particles with an efficiency of 99%. Its dimensions vary depending on the model it is fitted in. DIMENSIONS FILTER MODEL The cell is built entirely in anticorodal aluminium.
  • Page 11: Ionisation Wires

    AIR QUALITY Jan 2012 MOBILE 3 . 4 . 1 i o n i s a t i o n w i r e s The electrostatic cell has 9 ionising wires. These must be intact, clean and well-tensioned at all times. If one breaks, it is necessary to replace it.
  • Page 12: Electrical Safety Devices

    AIR QUALITY Jan 2012 MOBILE 4 . 2 E L E C T R I C A L S A F E T Y D E V I C E S The machine is provided with a door, through which access to the filters is permitted so as to carry out normal maintenance.
  • Page 13: Ordinary Maintenance

    AIR QUALITY Jan 2012 MOBILE O R D I N A R Y M A I N T E N A N C E Ordinary maintenance involves: maintenance of the filter unit general inspection of the machine Extraordinary maintenance is carried out by specialised personnel. 5 .
  • Page 14: Washing The Filters

    AIR QUALITY Jan 2012 MOBILE 5 . 1 . 2 W a s h i n g t h e f i l t e r s Filter maintenance is important both for the correct operation of the machine and for constant performance with the passage of time.
  • Page 15: General Inspection Of The Filters

    AIR QUALITY Jan 2012 MOBILE d) remove the cell and leave it to dry in a warm place, keeping it raised from the ground by wooden strips (ovens with a maximum temperature of 60°C are tolerated). e) examine the state of the ionisation wires, stretching them slightly to check their mechanical strength. Use a cotton flock and methylated spirits to remove any residual traces of dirt.
  • Page 16: Available Versions

    AIR QUALITY Jan 2012 MOBILE A V A I L A B L E V E R S I O N S The 50P line is manufactured in tree versions. For distinguishing which version you have, you should control the label placed outside on the machine or to check the control panel. ®...
  • Page 17 AIR QUALITY Jan 2012 MOBILE ® is the Top version of Environmental Air Purifiers and is using a digital technology for the AFC SYSTEM controlling of its functions. The operations carried out by this machine are reported in the following definitions: ®...
  • Page 18: Nature System

    AIR QUALITY Jan 2012 MOBILE  N A T U R E S Y S T E M The NATURE SYSTEM® is composed of the following elements: ® Electronic control of environmental revitalisation (rivitalizzazione ambientale The System automatically carries out all the controls and gives the commands to the Environmental Revitalisation along with the information required on the operating status of the apparatus.
  • Page 19: Control Panel

    AIR QUALITY Jan 2012 MOBILE 7 . 1 C O N T R O L P A N E L All information regarding the operating status of the machine is displayed on the control panel. The control panel allows the user to: - select the air flow - activate/deactivate environmental revitalisation - turn off any alarms indicating apparatus malfunctions...
  • Page 20: Manual, Test, On-Off Filter And Reset Buttons

    AIR QUALITY Jan 2012 MOBILE 7 . 1 . 3 M A N U A L , T E S T , O N - O F F F I L T E R A N D R E S E T B U T T O N S The MANUAL button allows the air flow to be modified manually (0-1-2-3);...
  • Page 21: Filtering Status

    AIR QUALITY Jan 2012 MOBILE 7 . 1 . 5 F I L T E R I N G S T A T U S The three Leds indicate the state of filtering efficiency and therefore only go on when filtration is activated; only one Led lights up at a time.
  • Page 22: Environmental Revitalisation

    AIR QUALITY Jan 2012 MOBILE 7 . 4 E N V I R O N M E N T A L R E V I T A L I S A T I O N ® ( R I V I T A L I Z Z A Z I O N E A M B I E N T A L E The Revitalizer revitalises the air in a confined environment in a completely automatic manner and until the pollutant has been completely cleaned from the environment.
  • Page 23: Night-Time Revitalisation With Environmental Deodorization

    AIR QUALITY Jan 2012 MOBILE 7 . 7 N I G H T - T I M E R E V I T A L I S A T I O N W I T H E N V I R O N M E N T A L D E O D O R I Z A T I O N If the Revitalizer is off or in flow position 2 or 3, this phase is activated by pressing button 1 of the infrared remote control unit three times consecutively, while if the flow is 1, the button should be pressed twice.
  • Page 24: Optimal Application Of The Revitalizer

    AIR QUALITY Jan 2012 MOBILE 7 . 1 0 O P T I M A L A P P L I C A T I O N O F T H E R E V I T A L I Z E R NATURE SYSTEM®...
  • Page 25: Electronic Circuit Alarm Signals

    AIR QUALITY Jan 2012 MOBILE 7 . 1 1 E L E C T R O N I C C I R C U I T A L A R M S I G N A L S The electronic circuit detects every cause of imperfect air filtration. If there is a slight drop in the efficiency of the machine, the yellow PRE-ALARM Led will light up.
  • Page 26: Electronic Circuit Anomalous Signals

    AIR QUALITY Jan 2012 MOBILE 7 . 1 2 E L E C T R O N I C C I R C U I T A N O M A L O U S S I G N A L S In some cases signals such as the following may occur: - the display goes off momentarily, - the letter ‘P’...
  • Page 27: Afc System

    AIR QUALITY Jan 2012 MOBILE  A F C S Y S T E M ® AFC SYSTEM The system automatically carries out all the controls and gives the commands to the high-efficiency filtration along with the information required on the operating status of the apparatus. Infrared remote control unit The remote control unit allows the user to control the operation of the machine from a distance of about 6÷7 metres;...
  • Page 28 AIR QUALITY Jan 2012 MOBILE 8 . 1 C O N T R O L P A N E L All information regarding the operating status of the machine is displayed on the control panel. The control panel allows the user to: - select the air flow - turn off any alarms indicating apparatus malfunctions - constantly control all the functions relating to operation (air flow, filtration efficiency, alarm situation).
  • Page 29: Manual, Test, On-Off Filter And Reset Buttons

    AIR QUALITY Jan 2012 MOBILE 8 . 1 . 3 M A N U A L , T E S T , O N - O F F F I L T E R A N D R E S E T B U T T O N S The MANUAL button allows the air flow to be modified manually (0-1-2-3);...
  • Page 30: Filtering Status

    AIR QUALITY Jan 2012 MOBILE 8 . 3 F I L T E R I N G S T A T U S The three Leds indicate the state of filtering efficiency and therefore only go on when filtration is activated; only one Led lights up at a time.
  • Page 31: Purification

    AIR QUALITY Jan 2012 MOBILE 8 . 6 P U R I F I C A T I O N The Air Purifier purifies the air by means of a high-efficiency electrostatic filter whose operation is governed by an electronic circuit which guarantees optimal and constant performance with time in any situation. 8 .
  • Page 32: Electronic Circuit Alarm Signals

    AIR QUALITY Jan 2012 MOBILE 8 . 9 E L E C T R O N I C C I R C U I T A L A R M S I G N A L S The electronic circuit detects every cause of imperfect air filtration. If there is a slight drop in the efficiency of the machine, the yellow PRE-ALARM Led will light up.
  • Page 33: Electronic Circuit Anomalous Signals

    AIR QUALITY Jan 2012 MOBILE 8 . 1 0 E L E C T R O N I C C I R C U I T A N O M A L O U S S I G N A L S In some cases signals such as the following may occur: - the display goes off momentarily, - the letter ‘P’...
  • Page 34: Basic System

    AIR QUALITY Jan 2012 MOBILE B A S I C S Y S T E M BASIC SYSTEM The System carries out the controls and gives the commands for filtration and negative ionisation along with the information required on the operating status of the apparatus. Infrared remote control unit The remote control unit allows the user to control the operation of the machine from a distance of about 6÷7 metres;...
  • Page 35: Control Panel

    AIR QUALITY Jan 2012 MOBILE 9 . 1 C O N T R O L P A N E L For modifying the operating status of the machine it is possible to use the control panel or the remote control. All information regarding the operating status of the machine is displayed on the control panel.
  • Page 36: Manual And On-Off Filter Buttons

    AIR QUALITY Jan 2012 MOBILE 9 . 2 . 2 M A N U A L A N D O N - O F F F I L T E R B U T T O N S The MANUAL button allows the air flow to be modified manually (OFF-1-2-3);...
  • Page 37: Purification

    AIR QUALITY Jan 2012 MOBILE 9 . 6 P U R I F I C A T I O N The Air Purifier purifies the air by means of a high-efficiency electrostatic filter whose operation is governed by an electronic circuit. 9 .
  • Page 38: Technical Data

    AIR QUALITY Jan 2012 MOBILE T E C H N I C A L D A T A model capacity Watt aliment. dimensions weight n° of kind of remote V - Hz cells installation control veloc. 300 veloc. 440 230 – 50 5488x370x302 20,5 supporting...

Table of Contents