Dc Output Test - Exmark 127-9041 Service Manual

V-twin air cooled engine
Table of Contents

Advertisement

DC Output Test

1.
Insert RED test lead into 1
2.
Insert BLACK test lead into COM receptacle in meter.
3.
Rotate selector to A== (DC AMPS) position.
4.
Attach RED test lead clip (1)
replace stator.
OA
receptacle in meter.
to
DC output pin (6)in connector (4), Fig.16. If NO or LOW output is found,
4-28