Page 1
14/11/090-V2 Professional Ultrasonic Cleaner User Manual Features Lengthened tank Tank capacity: 2500ml; Size: 24.5 x 15.0 x 7.6 cm / 9.6” x 5.9” x 3.0”. Longest item that can fit inside the tank is 26.0 cm / 10.2” Industrial grade Ø38 industrial transducer (60W), giving 170W cleaning power ultrasonic transducer Built-in heater...
Page 2
SPECIFICATION Description Digital Ultrasonic Cleaner Model ULTRA 8050 Tank Capacity 2500 ml Max. 2200 ml Min. 600 ml Power Supply 170 W (AC 220~240V 50/60Hz) Digital Timer Settings – 90s – 180s – 280s – 380s – 480s Ultrasonic Frequency...
Page 3
It also contains important safety information as well as practical hints. UNPACKING Remove your Ultra 8050 cleaner from its packaging and ensure that along with this User Guide you have the correct mains plug fitted for your supply and you have the specified accessories.
Page 4
FEATURES AND ACCESSORIES Viewing Window Control Panel Stainless Steel Tank Housing Control Panel Overview Left Indicator Right Indicator • Red - Heater on • Green - Ultrasonic on • Red - Overheat protection On/Off Buttons Set Button TC Button These control the main power Adjusts cycle time Switches the heater on/off Included Accessories...
Page 5
SAFETY INSTRUCTIONS Do not attempt to remove any screws or panels. There are no user serviceable parts inside. Do not operate this unit if the cord or plug is damaged. Please refer to a service centre for examination and repair. To avoid electric shock never touch the cord or socket with wet hands.
Page 6
The coating on some spectacle lenses can exhibit hairline cracking during ultrasonic cleaning. If in doubt check with your optician or with James Products Limited before cleaning such items. Toiletry items Electric toothbrush heads, electric shaver heads, razor blades, combs, toothbrushes, dentures etc.
• Some spectacles are not suitable for ultrasonic cleaning because the frames are made from porous materials. If you have any doubts, consult either the supplier of the spectacles or James Products before placing them in the ultrasonic cleaner.
Page 8
OPERATION INSTRUCTIONS How do I use the Ultra 8050 cleaner? Note: To avoid causing permanent damage: Never operate the unit without water in the cleaning tank. Never use boiling water. Open the lid. Place the items to be cleaned on the tray (supplied) and place the tray in the tank.
OPERATION INSTRUCTIONS Using the HEATER function. Press the “TC” button to start the built-in heater. The left-side red indicator on the control panel will illuminate. The fluid will heat to a maximum of 65 degrees C. To start the cleaning process press the ON button (as described in point 3).
Page 10
• Care should be taken when using different types of cleaning soaps or detergents. Always ensure they are suitable for the item you are cleaning. If in doubt, please ask James Products or check www.jamesproducts.co.uk. • If there is any danger of scratching to an item to be cleaned, then place the item on the plastic tray before immersing it in the tank.
Page 11
MAINTENANCE AND STORAGE How do I keep my cleaner in perfect condition? The Ultra 8050D-H cleaner has circuit protection to stop overheating. Never use the product without water as damage will occur. To prolong the life of the unit, it is recommended to stop using the unit for 15 minutes after every 3 working cycles.
*Repair or replacement is at the discretion of the manufacturer. www.jamesproducts.co.uk Registered in England No. 5250754 Registered Office: James Products Ltd, Unit 1, Church Close Business Park, Todber, Sturminster Newton, Dorset DT10 1JH, England...
Need help?
Do you have a question about the ULTRA 8050 and is the answer not in the manual?
Questions and answers