The MRS-1000 radar system is designed around X-band radar and consists of the following units: Outdoor equipment: CAUTION! • Radar (Antenna MRS-1000-AU and The antenna unit and rotation unit are de- Rotation Unit MRS-1000-RU); signed for operation under ambient air temperature conditions varying from minus •...
FEATURES SYSTEM OVERVIEW Radar uses FMCW (Frequency Modulated Con- Radar transmits a signal of increasing fre- tinuous Wave) radar technology. The main dis- quency. Measuring the difference between ABOUT FREQUENCY MODULATED CONTINUOUS WAVE (FMCW) tinguishing feature of broadband radar unlike the current transmitted frequency and echoed traditional pulsed radars is solid-state element frequency allows to calculate the time of the...
GENERAL INFORMATION SAFETY PRECAUTIONS Radar may only be operated by the staff who have studied this Operator's Manual and Safety CAUTION! Rules for Operation of Consuming Electric In- Before preventative maintenance opera- stallations. tions, turn the radar power off and discon- nect it from the 24 V electrical system.
GENERAL INFORMATION FUSE REPLACEMENT 5. Remove the fuse from the fuse holder con- nector arranged on the board. Replace the The radar system is fitted with fuses to protect fuse with a new one. power supply circuits in the following units: •...
Page 7
GENERAL INFORMATION Procedure for Communication Unit Fuse Re- placement If powered from 24VDC power supply circuit: If powered from the electrical system of 220VAC: 1. Detach 24VDC connector of the electrical system. 1. Set the 220VAC power switch to the OFF position.
GENERAL INFORMATION OPERATING LIMITATIONS The radar ensures operation under the operat- ing conditions listed in the Table below: Name of ambient condition Indoor equipment (MRS-1000-СU) Outdoor equipment (MRS-1000-AU, MRS-1000-RU, MRS-1000-CC) Value Value Elevated operating temperature, °С Reduced operating temperature, °С...
GENERAL INFORMATION DISPOSAL MANUFACTURER’S WARRANTY The radar does not contain any hazardous or The Manufacturer guarantees compliance of poisonous substances posing threat to human the radar with all specification requirements health or environment and is not dangerous for during two years, provided the user follows the life, human health or environment after expira- conditions and rules of transportation, storage, tion of the service (operating) life.
SPECIFICATIONS Description of parameter Parameter value 360-degree scanning rate, rpm 12 to 24 Range resolution, m Heading resolution, maximum 1° Operating frequency range, MHz 9300 to 9500 Modulation period, ms Maximum frequency deviation, MHz Transceiver design Solid state transceiver module Output power, max, W Peak-power-output adjustment, dB 0-28...
DELIVERY SET Overall Weight, Description dimensions (WхHхL), cm Antenna Unit MRS-1000-AU 10.5 200х17х15 Rotation Unit MRS-1000-RU 36х29х36 Communication cable MRS-1000-СС 20 m Communication Unit MRS-1000-СU 35х19х9 Operating documents Installation Manual Operator's Manual SPTA set...
Should you encounter any problems in the course of radar operation, you can contact our Customer Support. When making a call, be ready to name your organization owning the radar and the radar model. Contact information of Technical Support in Tomsk, Russia: E-mail: radar_service@micran.com...