CONTENT 3 Introduction 3 General technical description 3 Principle of working 4 Basic dimensions of water storage tanks 4 Basic technical data on storage tanks 5 ASSEMBLY 5 Connecting the water storage tank to gas supply 5 Connecting the water storage tank to water supply 6 Connecting to flue 6 OPERATION 6 Procedure of filling the tank with water...
INTRODUCTION This instruction serves mainly for the user of this storage tank. It contains basic technical information and steps necessary for putting the boiler into operation, for its smooth attendance and basic rules of maintenance. Some chapters and information written in this instruction are also meant as an informative guide for specialised organisations which will carry out assembly of the appliance at user's.
* Given values refer to heating without taking water and are only informative. The real values depend on specific conditions (temperature of inlet water, intervals of water consumption and so on). Inlet gas pressure: 2,0 kPa for natural gas G20 Overpressure : 1,1 kPa for natural gas Opening pressure of safety valve:...
NOTE Water must be treated by the standard. In case of deviation, an equipment for water treatment must be installed to the tank. WARNING The water storage tank cannot be put into operation in any case without the safety valve fitted and it cannot be removed.
START AND PUTTING WATER STORAGE TANK TO OPERATION Open the gas valve before the appliance. Turn the control button of the gas fitting anticlockwise to the position of ignition burner („ “ pilot). Press the control burner to stop and light the ignition burner by pressing the piezoelectric lighter.
WARNING! Because of possible condensation of vapour it is not recommended to set up water temperature to a value lower than 50°C. For running water it is necessary to mix water in the fitting. PUTTING THE WATER TANK OUT OF OPERATION The procedure is following: ...
FUME, SMELL OF FUME Smell of fume after ignition of the storage tank is not a defect or anything unusual. It is just a result of possible burning out of oil deposit on metal parts of the tank and the smell will stop in a short time.
WARNING FOR USER! When taking the storage tank over make sure whether the letter of guarantee is confirmed properly. Reclaim defects immediately otherwise you lose your right for guarantee. Check whether the equipment was not damaged during transport and if it was, claim the guarantee at the transporter.
NOTES Device commissioning report Data of the customer: (legibly) Serial number: ..........Name and surname: Date of commission: ......................... Service organization: Street: ..............ZIP code, town: ......................... Stamp, signature Tel.: ..............Obligatory service inspection after the 1st year of operation Date: ......
Page 12
Výrobca ATTACK, s.r.o. si vyhradzuje právo technických zmien výrobkov bez predchádzajúceho upozor- nenia. • ATTACK, s.r.o. producer reserves the right to change technical parameters and dimensions of boilers without previous warning. • Der Hersteller ATTACK, s.r.o. behält sich das Recht der technischen Veräderungen an Produkten ohne eine vorige Warnung.