3-2 Specifications (continuance)
Model
0-30V/10A
Constant Voltage Operation
Line regulation
CV≤0.01%+5mV
Load regulation
CV≤0.02%+5mV
&
Riple
Noise
CV≤2mV(rms)
。
300ppm/ C
Temperature coefficient
Constant Current Operation
Line regulation
CC≤0.2%+3mA
Load regulation
CC≤0.2%+5mA
&
Riple
Noise
CC≤3mA
。
Temperature coefficient
500ppm/ C
Display accuracy:
Three LED≤1%+2d
Recover time
≤100μS
5
0-60V/3A
0-60V/5A
4-2.
Rear panel
17
Power Socket
18
Fuse holder:
Fuse rate
30V/3A series:
30V/5A series:
60V/3Aseries:
60V/5A
30V/10A
The power transformer is designed to permit operation in
19
AC selects switch:
110V (115V/120V) or 220V(230V/240V),50/60Hz line voltage.
(customer optional)
To convert from one line voltage to another is done by change
AC selector as shown in page 8.
20 Fan
220V
110VA
1.5A
3A
3.15A
6.3A
3.15A
6.3A
6.3A
10A
6.3A
10A
10