Summary of Contents for Test Equipment Depot PS-1303C

  • Page 1 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com REGULATED D.C. POWER SUPPLY USER MANUAL...
  • Page 2: Table Of Contents

    CONTENTS 1.INTRODUCTION 2.PRODUCTION MODELS 3.SPECIFICATIONS 3-1 General 3-2 Specifications 4.PANEL CONTROLS AND INDCATORS a. 30V3A/30V5A/60V3A Front panel b. 30V3A/30V5A/60V3A Rear Panel c. 60V5A/30V10A Front Panel d. 60V5A/30V10A Rear Panel 4-1 Front Panel 4-2 Rear Panel 5.OPERATION INSTRUCTIONS 5-1 Precaution 5-2 Setting Current Limit Specifications are subject to change without notice.
  • Page 3: Introduction

    The unit can be used as either constant voltage or current source. It has output standby function (optional), fixed DC 5V/1A output (optional).Four digital LED display (optional). Overload protection circuits. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 4: Production Models

    Model Standby Voltage Current 5V/1A WARNING PS-1303C 0-30V The following instructions are for use by qualified personnel only.To avoid electrical shock, do not perform PS-1303 0-30V PS-1305C any servicing other than contained in the operating instruction unless you are qualified to do so.
  • Page 5: Specifications

    3.SPECIFICATIONS Setting Constant Voltage 3-1 General Turn the power switch on, the CV indicator light. % Main Supply: 110/220V±10 , 50/60Hz Switch selectable (customer optional) Rotating the Coarse and Fine voltage control to the desired volts. 。 。 Operation Temperature & Humidity 0 C to 40 C,<80% Press Output standby button, the output standby indicator light, then the terminals have voltage output.
  • Page 6: Specifications

    The current limit (overload protection) now has been preset. Do not change the CURRENT control setting after this step. & ≤2mV(rms) Riple Noise: CV Remove the short lead between the"+" and"-" terminals. Display accuracy: Three LED≤1%+2d Recover time ≤100μS Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 7 3-2 Specifications (continuance) 4-2. Rear panel Model 0-30V/10A 0-60V/3A 0-60V/5A Power Socket Fuse holder: Fuse rate 220V 110VA Constant Voltage Operation 30V/3A series: 1.5A Line regulation CV≤0.01%+5mV 30V/5A series: 3.15A 6.3A Load regulation CV≤0.02%+5mV 60V/3Aseries: 3.15A 6.3A & Riple Noise CV≤2mV(rms)...
  • Page 8: Panel Controls And Indcators

    4-1 Front Panel 4. PANEL CONTROLS AND INDICATORS a .30V3A/30V5A/60V3A Front panel: b .30V3A/30V5A/60V3A Rear Panel: Power switch: ON/OFF the power Output standby: After power on, there are no voltage cross the terminals. Press this button, output LED on, unit has power out.Repress this button, output LED off, output voltage cross the terminals is zero, unit is on standby mode.
  • Page 9: 60V5A/30V10A Front Panel

    .60V5A/30V10A Front Panel Controls and lindicator: .60V5A/30V10A Rear Panel lndicator FINE COARSE FINE COARSE OUTPUT ON/OFF C.V. C.C. CURRENT VOLTAGE POWER Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...

Table of Contents