OCL DLC-1.1 Manual

X-series smart lighting & co2 controller
Hide thumbs Also See for DLC-1.1:

Advertisement

Quick Links

CONTROLLER
MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DLC-1.1 and is the answer not in the manual?

Questions and answers

Summary of Contents for OCL DLC-1.1

  • Page 1 CONTROLLER MANUAL...
  • Page 2 Different from other brands, with the OCL DLC-1.1 controller it is possible to combine different types of ballasts. It is therefore possible to connect, say, a OCL XXL 1000 watt fixture with a 315 watt CDM fixture on one and the same controller.
  • Page 3 DC INPUT TEMP 13V Max 1.5A Max DEHUMIDIFIER HEATER BOX CONTENTS: OPTIONAL: 1 - OCL DLC-1.1 Digital Lighting Controller 5 - CO2 Sensor 2 - AC Adapter 240V 6 - Aux Box 3 - Temperature Sensor 4 - Humidity Sensor...
  • Page 4: Tips And Tricks

    As the first and only, the OCL Digital Lighting Controller uses the interlink cable to connect ballasts via the output of the one to the input of the other. Without any problem up to 50 OCL XXL-SERIE Full Fixtures can be simultaneously controlled by the OCL DLC-1.1.
  • Page 5: Control Key

    I. PREPARATIONS BEFORE USE Set the controller output mode to “OFF”, to ensure that it will not be accidentally activated during the controller setup. DOWN MODES II. CONTROL KEY TEMP: 27.4 °C OUTPUT SELECT TEMP: SENSOR FAILURE HUM : 52% OUTPUT POWER HUM : SENSOR FAILURE LIGHT TIMER...
  • Page 6: Light Timer

    3. LIGHT TIMER Press setting key, choose “LIGHT TIMER”, press setting key again, you can change the setting “LIGHT TIMER” to on and off by the up and down key. You can change the hours and minutes with the setting key. Finally, press the setting key again, this will confirm the function and return to the main menu.
  • Page 7: Display Select

    7. DISPLAY SELECT Press setting key, choose “DISPLAY SELECT”, press setting key, you can change the setting “DISPLAY SELECT” by the up and down key. Then, press setting key again, you can choose connected ballast with the up and down key. After confirmation, press setting key and return to the main menu.
  • Page 8: Temp Calibrate

    10. HUM CALIBRATE Press setting key, choose “HUM CALIBRATE”, now, the controller will display the correct humidity. You can change the setting “HUM CALIBRATE” with the up and down key. After confirmation, press the setting key and return to the main menu. If not, please press ESC key.
  • Page 9: Factory Reset

    15. CO2 START/STOP TIME Press setting key, choose “CO2 START/STOP TIME”, press setting key, you will enter the CO2 START/STOP set time. Press setup key, you can set the CO2 start or stop time. After confirmation, press the setting key and return to the main menu. If not, please press ESC key.

Table of Contents